3.5 Low
CVSS2
Attack Vector
NETWORK
Attack Complexity
MEDIUM
Authentication
SINGLE
Confidentiality Impact
NONE
Integrity Impact
PARTIAL
Availability Impact
NONE
AV:N/AC:M/Au:S/C:N/I:P/A:N
4.5 Medium
CVSS3
Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
HIGH
User Interaction
REQUIRED
Scope
UNCHANGED
Confidentiality Impact
NONE
Integrity Impact
HIGH
Availability Impact
NONE
CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:H/A:N
4.7 Medium
AI Score
Confidence
High
0.0004 Low
EPSS
Percentile
10.6%
A CWE-352: Cross-Site Request Forgery vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause a user to perform an unintended action on the target device when using the HTTP web interface.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(500674);
script_version("1.6");
script_set_attribute(attribute:"plugin_modification_date", value:"2024/02/20");
script_cve_id("CVE-2021-22701");
script_name(english:"Schneider Electric PowerLogic Cross-Site Request Forgery (CVE-2021-22701)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"A CWE-352: Cross-Site Request Forgery vulnerability exists in
PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800,
ION9000 and PM800 (see notification for affected versions), that could
cause a user to perform an unintended action on the target device when
using the HTTP web interface.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://www.se.com/ww/en/download/document/SEVD-2021-040-01/");
script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
script_set_cvss_base_vector("CVSS2#AV:N/AC:M/Au:S/C:N/I:P/A:N");
script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:H/A:N");
script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2021-22701");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_set_attribute(attribute:"exploit_available", value:"false");
script_cwe_id(352);
script_set_attribute(attribute:"vuln_publication_date", value:"2021/02/19");
script_set_attribute(attribute:"patch_publication_date", value:"2021/02/19");
script_set_attribute(attribute:"plugin_publication_date", value:"2022/07/21");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:powerlogic_ion7400_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:powerlogic_ion7650_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:powerlogic_ion8300_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:powerlogic_ion8400_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:powerlogic_ion8500_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:powerlogic_ion8600_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:powerlogic_ion8650_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:powerlogic_ion8800_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:powerlogic_ion9000_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:powerlogic_pm8000_firmware");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2022-2024 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Schneider");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Schneider');
var asset = tenable_ot::assets::get(vendor:'Schneider');
var vuln_cpes = {
"cpe:/o:schneider-electric:powerlogic_ion7400_firmware" :
{"versionEndExcluding" : "3.0.0", "family" : "ION"},
"cpe:/o:schneider-electric:powerlogic_ion7650_firmware" :
{"family" : "ION"},
"cpe:/o:schneider-electric:powerlogic_ion8600_firmware" :
{"family" : "ION"},
"cpe:/o:schneider-electric:powerlogic_ion8650_firmware" :
{"versionEndIncluding" : "4.31.2", "family" : "ION"},
"cpe:/o:schneider-electric:powerlogic_ion8800_firmware" :
{"family" : "ION"},
"cpe:/o:schneider-electric:powerlogic_ion9000_firmware" :
{"versionEndExcluding" : "3.0.0", "family" : "ION"},
"cpe:/o:schneider-electric:powerlogic_pm8000_firmware" :
{"versionEndExcluding" : "3.0.0", "family" : "PowerLogicPM"},
"cpe:/o:schneider-electric:powerlogic_ion8300_firmware" :
{"family" : "ION"},
"cpe:/o:schneider-electric:powerlogic_ion8400_firmware" :
{"family" : "ION"},
"cpe:/o:schneider-electric:powerlogic_ion8500_firmware" :
{"family" : "ION"}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_NOTE);
Vendor | Product | Version | CPE |
---|---|---|---|
schneider-electric | powerlogic_ion7400_firmware | cpe:/o:schneider-electric:powerlogic_ion7400_firmware | |
schneider-electric | powerlogic_ion7650_firmware | cpe:/o:schneider-electric:powerlogic_ion7650_firmware | |
schneider-electric | powerlogic_ion8300_firmware | cpe:/o:schneider-electric:powerlogic_ion8300_firmware | |
schneider-electric | powerlogic_ion8400_firmware | cpe:/o:schneider-electric:powerlogic_ion8400_firmware | |
schneider-electric | powerlogic_ion8500_firmware | cpe:/o:schneider-electric:powerlogic_ion8500_firmware | |
schneider-electric | powerlogic_ion8600_firmware | cpe:/o:schneider-electric:powerlogic_ion8600_firmware | |
schneider-electric | powerlogic_ion8650_firmware | cpe:/o:schneider-electric:powerlogic_ion8650_firmware | |
schneider-electric | powerlogic_ion8800_firmware | cpe:/o:schneider-electric:powerlogic_ion8800_firmware | |
schneider-electric | powerlogic_ion9000_firmware | cpe:/o:schneider-electric:powerlogic_ion9000_firmware | |
schneider-electric | powerlogic_pm8000_firmware | cpe:/o:schneider-electric:powerlogic_pm8000_firmware |
3.5 Low
CVSS2
Attack Vector
NETWORK
Attack Complexity
MEDIUM
Authentication
SINGLE
Confidentiality Impact
NONE
Integrity Impact
PARTIAL
Availability Impact
NONE
AV:N/AC:M/Au:S/C:N/I:P/A:N
4.5 Medium
CVSS3
Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
HIGH
User Interaction
REQUIRED
Scope
UNCHANGED
Confidentiality Impact
NONE
Integrity Impact
HIGH
Availability Impact
NONE
CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:H/A:N
4.7 Medium
AI Score
Confidence
High
0.0004 Low
EPSS
Percentile
10.6%