A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible denial of Service when writing invalid memory blocks to the controller over Modbus.
This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information.
#%NASL_MIN_LEVEL 70300
##
# (C) Tenable Network Security, Inc.
##
include('deprecated_nasl_level.inc');
include('compat.inc');
if (description)
{
script_id(500124);
script_version("1.6");
script_set_attribute(attribute:"plugin_modification_date", value:"2024/01/24");
script_cve_id("CVE-2018-7856");
script_name(english:"Schneider Electric Modicon Improper Check for Unusual or Exceptional Conditions (CVE-2018-7856)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum,
and Modicon Premium which could cause a possible denial of Service when writing invalid memory blocks to the controller
over Modbus.
This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more
information.");
# https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0767
script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?6a850ca2");
# https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2019-134-11
script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?a432fe19");
script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:N/I:N/A:P");
script_set_cvss_temporal_vector("CVSS2#E:POC/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H");
script_set_cvss3_temporal_vector("CVSS:3.0/E:P/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2018-7856");
script_set_attribute(attribute:"exploitability_ease", value:"Exploits are available");
script_set_attribute(attribute:"exploit_available", value:"true");
script_cwe_id(754);
script_set_attribute(attribute:"vuln_publication_date", value:"2019/05/22");
script_set_attribute(attribute:"patch_publication_date", value:"2019/05/22");
script_set_attribute(attribute:"plugin_publication_date", value:"2022/02/07");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_premium_firmware:-");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_quantum_firmware:-");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m340_series_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:modicon_m580_series_firmware");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2022-2024 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Schneider");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Schneider');
var asset = tenable_ot::assets::get(vendor:'Schneider');
var vuln_cpes = {
"cpe:/o:schneider-electric:modicon_premium_firmware:-" :
{"versionEndExcluding" : "3.20", "family" : "Premium"},
"cpe:/o:schneider-electric:modicon_quantum_firmware:-" :
{"versionEndExcluding" : "3.60", "family" : "QuantumUnity"},
"cpe:/o:schneider-electric:modicon_m340_series_firmware" :
{"versionEndExcluding" : "3.10", "family" : "ModiconM340"},
"cpe:/o:schneider-electric:modicon_m580_series_firmware" :
{"versionEndExcluding" : "2.80", "family" : "ModiconM580"}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);
CVSS2
Attack Vector
NETWORK
Attack Complexity
LOW
Authentication
NONE
Confidentiality Impact
NONE
Integrity Impact
NONE
Availability Impact
PARTIAL
AV:N/AC:L/Au:N/C:N/I:N/A:P
CVSS3
Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
NONE
Scope
UNCHANGED
Confidentiality Impact
NONE
Integrity Impact
NONE
Availability Impact
HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
EPSS
Percentile
54.0%