Schneider Electric PowerLogic PM5560 Improper Neutralization of Input During Web Page Generation (CVE-2018-7795)

2022-02-0700:00:00
This script is Copyright (C) 2022-2024 and is owned by Tenable, Inc. or an Affiliate thereof.
www.tenable.com
13
schneider electric
pm5560
cross protocol injection
cve-2018-7795
vulnerability
web browser
script execution
security notification
fix
update
schneider.

CVSS2

4.3

Attack Vector

NETWORK

Attack Complexity

MEDIUM

Authentication

NONE

Confidentiality Impact

NONE

Integrity Impact

PARTIAL

Availability Impact

NONE

AV:N/AC:M/Au:N/C:N/I:P/A:N

CVSS3

6.1

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

REQUIRED

Scope

CHANGED

Confidentiality Impact

LOW

Integrity Impact

LOW

Availability Impact

NONE

CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N

EPSS

0.002

Percentile

60.6%

A Cross Protocol Injection vulnerability exists in Schneider Electric’s PowerLogic (PM5560 prior to FW version 2.5.4) product. The vulnerability makes the product susceptible to cross site scripting attack on its web browser. User inputs can be manipulated to cause execution of java script code.

This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information.

#%NASL_MIN_LEVEL 70300
##
# (C) Tenable Network Security, Inc.
##

include('deprecated_nasl_level.inc');
include('compat.inc');

if (description)
{
  script_id(500552);
  script_version("1.12");
  script_set_attribute(attribute:"plugin_modification_date", value:"2024/09/04");

  script_cve_id("CVE-2018-7795");
  script_xref(name:"ICSA", value:"18-240-03");

  script_name(english:"Schneider Electric PowerLogic PM5560 Improper Neutralization of Input During Web Page Generation (CVE-2018-7795)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"A Cross Protocol Injection vulnerability exists in Schneider Electric's PowerLogic (PM5560 prior to FW version 2.5.4)
product. The vulnerability makes the product susceptible to cross site scripting attack on its web browser. User inputs
can be manipulated to cause execution of java script code.  

This plugin only works with Tenable.ot. Please visit
https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"http://www.securityfocus.com/bid/105170");
  script_set_attribute(attribute:"see_also", value:"https://ics-cert.us-cert.gov/advisories/ICSA-18-240-03");
  # https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2018-228-01
  script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?9bf7cd9e");
  script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.

Schneider Electric has released a fix to address this vulnerability:

https://www.schneider-electric.com/en/download/document/PM5560_PM5563_V2.5.4_Release/

For more information please see the Schneider Electric security notification at: 

https://www.schneider-electric.com/en/download/document/SEVD-2018-228-01/");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:M/Au:N/C:N/I:P/A:N");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2018-7795");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");
  script_cwe_id(79);

  script_set_attribute(attribute:"vuln_publication_date", value:"2018/08/29");
  script_set_attribute(attribute:"patch_publication_date", value:"2018/08/29");
  script_set_attribute(attribute:"plugin_publication_date", value:"2022/02/07");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:schneider-electric:powerlogic_pm5560_firmware");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2022-2024 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Schneider");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Schneider');

var asset = tenable_ot::assets::get(vendor:'Schneider');

var vuln_cpes = {
    "cpe:/o:schneider-electric:powerlogic_pm5560_firmware" :
        {"versionEndExcluding" : "2.5.4", "family" : "PowerLogicPM"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);

CVSS2

4.3

Attack Vector

NETWORK

Attack Complexity

MEDIUM

Authentication

NONE

Confidentiality Impact

NONE

Integrity Impact

PARTIAL

Availability Impact

NONE

AV:N/AC:M/Au:N/C:N/I:P/A:N

CVSS3

6.1

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

REQUIRED

Scope

CHANGED

Confidentiality Impact

LOW

Integrity Impact

LOW

Availability Impact

NONE

CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N

EPSS

0.002

Percentile

60.6%

Related for TENABLE_OT_SCHNEIDER_CVE-2018-7795.NASL