Rockwell Automation CompactLogix 5370 Improper Validation of Integrity Check Value (CVE-2025-11694)

🗓️ 29 Jul 2026 00:00:00Reported by TenableType 
nessus
 nessus
🔗 www.tenable.com👁 3 Views

CompactLogix 5370 has improper CIP integrity validation enabling forged packets to cause denial.

Related
Refs
Code
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(505884);
  script_version("1.2");
  script_set_attribute(attribute:"plugin_modification_date", value:"2026/07/30");

  script_cve_id("CVE-2025-11694");
  script_xref(name:"ICSA", value:"26-167-04");

  script_name(english:"Rockwell Automation CompactLogix 5370 Improper Validation of Integrity Check Value (CVE-2025-11694)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"A security issue exists within the affected CompactLogix 5370
controllers due to missing validation of sequence numbers and source
IP addresses in the CIP protocol. An attacker can abuse the exposed
Connection IDs visible on the controller's web interface to send
forged CIP packets, resulting in a minor fault and a denial-of-service
condition.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  # https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1776.html
  script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?74a39431");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-26-167-04");
  script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.

Rockwell Automation recommends users update CompactLogix 5370 L1, L2, and L3 controllers to Version 38.011 or later.");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss4_vector", value:"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N");
  script_set_attribute(attribute:"cvss4_threat_vector", value:"CVSS:4.0/E:U");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2025-11694");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");
  script_cwe_id(354);

  script_set_attribute(attribute:"vuln_publication_date", value:"2026/06/16");
  script_set_attribute(attribute:"patch_publication_date", value:"2026/06/16");
  script_set_attribute(attribute:"plugin_publication_date", value:"2026/07/29");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:rockwellautomation:compactlogix_5370_l1_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:rockwellautomation:compactlogix_5370_l2_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:rockwellautomation:compactlogix_5370_l3_firmware");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2026 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Rockwell");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Rockwell');

var asset = tenable_ot::assets::get(vendor:'Rockwell');

var vuln_cpes = {
    "cpe:/o:rockwellautomation:compactlogix_5370_l1_firmware" :
        {"versionEndExcluding" : "38.011", "family" : "CompactLogix5370"},
    "cpe:/o:rockwellautomation:compactlogix_5370_l2_firmware" :
        {"versionEndExcluding" : "38.011", "family" : "CompactLogix5370"},
    "cpe:/o:rockwellautomation:compactlogix_5370_l3_firmware" :
        {"versionEndExcluding" : "38.011", "family" : "CompactLogix5370"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation