| Reporter | Title | Published | Views | Family All 12 |
|---|---|---|---|---|
| The vulnerability of the microprogramming software for Rockwell Automation’s ArmorStart ST controllers, related to insufficient validation of input data, allows attackers to execute cross-site scripting (XSS) attacks. | 20 Jun 202300:00 | – | bdu_fstec | |
| CVE-2023-29028 | 11 May 202322:20 | – | circl | |
| Rockwell Automation ArmorStart ST 跨站脚本漏洞 | 11 May 202300:00 | – | cnnvd | |
| Rockwell Automation ArmorStart ST Cross-Site Scripting Vulnerability (CNVD-2023-44293) | 15 May 202300:00 | – | cnvd | |
| CVE-2023-29028 | 11 May 202317:50 | – | cve | |
| CVE-2023-29028 Rockwell Automation ArmorStart ST Vulnerable to Cross-Site Scripting Attack | 11 May 202317:50 | – | cvelist | |
| EUVD-2023-32633 | 3 Oct 202520:07 | – | euvd | |
| Rockwell ArmorStart | 18 May 202319:01 | – | ics | |
| CVE-2023-29028 | 11 May 202318:15 | – | nvd | |
| Cross site scripting | 11 May 202318:15 | – | prion |
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(501164);
script_version("1.11");
script_set_attribute(attribute:"plugin_modification_date", value:"2026/04/21");
script_cve_id("CVE-2023-29028");
script_xref(name:"ICSA", value:"23-136-02");
script_name(english:"Rockwell ArmorStart Improper Input Validation (CVE-2023-29028)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"A cross site scripting vulnerability was discovered in Rockwell
Automation's ArmorStart ST product that could potentially allow a
malicious user with admin privileges and network access to view user
data and modify the web interface. Additionally, a malicious user
could potentially cause interruptions to the availability of the web
page.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
# https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1139438
script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?dc879700");
script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-23-136-02");
# https://www.rockwellautomation.com/en-us/support/advisory.PN1622.html
# script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?77f8af70");
script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.
Rockwell Automation recommends users take the following measures to mitigate the risk of these vulnerabilities:
- Disable the webserver during normal use. The webserver is disabled by default and should only be enabled to modify
configurations. After modifying configurations, the web server should be disabled.
- For information on how to mitigate security risks on industrial automation control systems (IACS) networks see the
following publications:
- System Security Design Guidelines Reference Manual publication, SECURE-RM001
- Configure System Security Features User Manual, SECURE-UM001
- Additionally, Rockwell Automation encourages customers to implement their suggested Security Best Practices to
minimize the risk of the vulnerabilities.");
script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:M/C:P/I:P/A:P");
script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:L");
script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2023-29028");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_cwe_id(79);
script_set_attribute(attribute:"vuln_publication_date", value:"2023/05/11");
script_set_attribute(attribute:"patch_publication_date", value:"2023/05/11");
script_set_attribute(attribute:"plugin_publication_date", value:"2023/05/24");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:rockwellautomation:armorstart_st_281e_firmware:-");
script_set_attribute(attribute:"cpe", value:"cpe:/o:rockwellautomation:armorstart_st_284ee_firmware:-");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2023-2026 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/Rockwell");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/Rockwell');
var asset = tenable_ot::assets::get(vendor:'Rockwell');
var vuln_cpes = {
"cpe:/o:rockwellautomation:armorstart_st_284ee_firmware:-" :
{"family" : "ArmorStartST"},
"cpe:/o:rockwellautomation:armorstart_st_281e_firmware:-" :
{"family" : "ArmorStartST", "versionStartIncluding" : "2.004.06"}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation