Rockwell Automation Logix Controllers Inclusion of Functionality From Untrusted Control Sphere (CVE-2022-1161)

2022-04-2800:00:00
This script is Copyright (C) 2022-2024 and is owned by Tenable, Inc. or an Affiliate thereof.
www.tenable.com
77
rockwell automation
logix controllers
untrusted control sphere

CVSS2

7.5

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

PARTIAL

Integrity Impact

PARTIAL

Availability Impact

PARTIAL

AV:N/AC:L/Au:N/C:P/I:P/A:P

CVSS3

10

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

CHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H

AI Score

9.6

Confidence

High

EPSS

0.001

Percentile

41.5%

An attacker with the ability to modify a user program may change user program code on some ControlLogix, CompactLogix, and GuardLogix Control systems. Studio 5000 Logix Designer writes user-readable program code to a separate location than the executed compiled code, allowing an attacker to change one and not the other.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

#%NASL_MIN_LEVEL 70300
##
# (C) Tenable, Inc.
##

include('deprecated_nasl_level.inc');
include('compat.inc');

if (description)
{
  script_id(500630);
  script_version("1.10");
  script_set_attribute(attribute:"plugin_modification_date", value:"2024/09/04");

  script_cve_id("CVE-2022-1161");
  script_xref(name:"ICSA", value:"22-090-05");

  script_name(english:"Rockwell Automation Logix Controllers Inclusion of Functionality From Untrusted Control Sphere (CVE-2022-1161)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"An attacker with the ability to modify a user program may change user
program code on some ControlLogix, CompactLogix, and GuardLogix
Control systems. Studio 5000 Logix Designer writes user-readable
program code to a separate location than the executed compiled code,
allowing an attacker to change one and not the other.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-05");
  script_set_attribute(attribute:"see_also", value:"https://www.rockwellautomation.com/en-us/support/advisory.PN1585.html");
  # https://claroty.com/team82/research/hiding-code-on-rockwell-automation-plcs
  script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?7c944bfe");
  # https://www.rockwellautomation.com/en-us/support/advisory.PN1585.html
  script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?e0526e5e");
  script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.

Users using the affected software or controllers are directed towards the risk mitigation steps listed below and are
encouraged, when possible, to combine this guidance with the general security guidelines for a comprehensive defense-in-
depth strategy.

The following mitigations should be applied for ControlLogix 5560, ControlLogix 5570, ControlLogix 5580 series,
GuardLogix 5570, GuardLogix 5580, GuardLogix 5380, CompactLogix, CompactLogix 5380 devices:

Risk Mitigation A:

- Recompile and download user program code (i.e., acd).
- Put controller mode switch into Run position.

If keeping controller mode switch in Run is impractical, use the following mitigation:

- Recompile and download user program code (i.e., acd).
- Monitor controller change log for any unexpected modifications or anomalous activity.
- Utilize the Controller Log feature.
- Utilize Change Detection in the Logix Designer Application.
- If available, use the functionality in FactoryTalk AssetCenter software to detect changes.

Risk Mitigation B:

Implement CIP Security to help prevent unauthorized connections when properly deployed. Supported controllers and
communications modules include:

- ControlLogix 5580 processors using on-board EtherNet/IP port.
- GuardLogix 5580 processors using on-board EtherNet/IP port.
- ControlLogix 5580 processors operating in High Availability (HA) configurations using 1756-EN4TR
- ControlLogix 5560, ControlLogix 5570, ControlLogix 5580, GuardLogix 5570 and GuardLogix 5580 can use a 1756-EN4TR
ControlLogix EtherNet/IP module.
    - If using a 1756-EN2T, then replace with a 1756-EN4TR
- CompactLogix 5380 using on-board EtherNet/IP port.
- CompactLogix GuardLogix 5380 using on-board EtherNet/IP port.

The following mitigations should be applied for 1768 CompactLogix, 1769 CompactLogix, CompactLogix 5370, and
CompactLogix 5480 devices:

- Recompile and download user program code (i.e., acd).
- Put controller mode switch into Run position.

If keeping controller mode switch in Run is impractical, then use the following mitigation:

- Recompile and download user program code (i.e., acd).
- Monitor controller change log for any unexpected modifications or anomalous activity.
- Use the Controller Log feature.
- Use Change Detection in the Logix Designer application.
- If available, use the functionality in FactoryTalk AssetCenter to detect changes.");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:P/I:P/A:P");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2022-1161");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");
  script_cwe_id(829);

  script_set_attribute(attribute:"vuln_publication_date", value:"2022/04/11");
  script_set_attribute(attribute:"patch_publication_date", value:"2022/04/11");
  script_set_attribute(attribute:"plugin_publication_date", value:"2022/04/28");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:rockwellautomation:compact_guardlogix_5370_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:rockwellautomation:compact_guardlogix_5380_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:rockwellautomation:compactlogix_1768-l43_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:rockwellautomation:compactlogix_1768-l45_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:rockwellautomation:compactlogix_1769-l31_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:rockwellautomation:compactlogix_1769-l32c_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:rockwellautomation:compactlogix_1769-l32e_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:rockwellautomation:compactlogix_1769-l35cr_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:rockwellautomation:compactlogix_1769-l35e_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:rockwellautomation:compactlogix_5370_l1_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:rockwellautomation:compactlogix_5370_l2_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:rockwellautomation:compactlogix_5370_l3_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:rockwellautomation:compactlogix_5380_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:rockwellautomation:compactlogix_5480_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:rockwellautomation:controllogix_5550_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:rockwellautomation:controllogix_5560_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:rockwellautomation:controllogix_5570_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:rockwellautomation:controllogix_5580_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:rockwellautomation:drivelogix_5730_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:rockwellautomation:flexlogix_1794-l34_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:rockwellautomation:guardlogix_5560_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:rockwellautomation:guardlogix_5570_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:rockwellautomation:guardlogix_5580_firmware");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:rockwellautomation:softlogix_5800_firmware");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2022-2024 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Rockwell");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Rockwell');

var asset = tenable_ot::assets::get(vendor:'Rockwell');

var vuln_cpes = {
    "cpe:/o:rockwellautomation:compactlogix_1768-l43_firmware" :
        {"family" : "CompactLogix5340"},
    "cpe:/o:rockwellautomation:compactlogix_1768-l45_firmware" :
        {"family" : "CompactLogix5340"},
    "cpe:/o:rockwellautomation:compactlogix_1769-l31_firmware" :
        {"family" : "CompactLogix5330"},
    "cpe:/o:rockwellautomation:compactlogix_1769-l32c_firmware" :
        {"family" : "CompactLogix5330"},
    "cpe:/o:rockwellautomation:compactlogix_1769-l32e_firmware" :
        {"family" : "CompactLogix5330"},
    "cpe:/o:rockwellautomation:compactlogix_1769-l35cr_firmware" :
        {"family" : "CompactLogix5330"},
    "cpe:/o:rockwellautomation:compactlogix_1769-l35e_firmware" :
        {"family" : "CompactLogix5330"},
    "cpe:/o:rockwellautomation:compactlogix_5370_l3_firmware" :
        {"family" : "CompactLogix5370"},
    "cpe:/o:rockwellautomation:compactlogix_5370_l2_firmware" :
        {"family" : "CompactLogix5370"},
    "cpe:/o:rockwellautomation:compactlogix_5370_l1_firmware" :
        {"family" : "CompactLogix5370"},
    "cpe:/o:rockwellautomation:compactlogix_5380_firmware" :
        {"family" : "CompactLogix5380"},
    "cpe:/o:rockwellautomation:compactlogix_5480_firmware" :
        {"family" : "CompactLogix5480"},
    "cpe:/o:rockwellautomation:compact_guardlogix_5370_firmware" :
        {"family" : "GuardLogix5370"},
    "cpe:/o:rockwellautomation:compact_guardlogix_5380_firmware" :
        {"family" : "GuardLogix5380"},
    "cpe:/o:rockwellautomation:controllogix_5550_firmware" :
        {"family" : "ControlLogix5550"},
    "cpe:/o:rockwellautomation:controllogix_5560_firmware" :
        {"family" : "ControlLogix5560"},
    "cpe:/o:rockwellautomation:controllogix_5570_firmware" :
        {"family" : "ControlLogix5570"},
    "cpe:/o:rockwellautomation:controllogix_5580_firmware" :
        {"family" : "ControlLogix5580"},
    "cpe:/o:rockwellautomation:guardlogix_5560_firmware" :
        {"family" : "GuardLogix5560"},
    "cpe:/o:rockwellautomation:guardlogix_5570_firmware" :
        {"family" : "GuardLogix5570"},
    "cpe:/o:rockwellautomation:guardlogix_5580_firmware" :
        {"family" : "GuardLogix5580"},
    "cpe:/o:rockwellautomation:flexlogix_1794-l34_firmware" :
        {"family" : "FlexLogix"},
    "cpe:/o:rockwellautomation:drivelogix_5730_firmware" :
        {"family" : "DriveLogix"},
    "cpe:/o:rockwellautomation:softlogix_5800_firmware" :
        {"family" : "SoftLogix5800"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
VendorProductVersionCPE
rockwellautomationcompactlogix_1768-l43_firmwarecpe:/o:rockwellautomation:compactlogix_1768-l43_firmware
rockwellautomationguardlogix_5570_firmwarecpe:/o:rockwellautomation:guardlogix_5570_firmware
rockwellautomationcompactlogix_1769-l32e_firmwarecpe:/o:rockwellautomation:compactlogix_1769-l32e_firmware
rockwellautomationflexlogix_1794-l34_firmwarecpe:/o:rockwellautomation:flexlogix_1794-l34_firmware
rockwellautomationcompactlogix_1769-l35e_firmwarecpe:/o:rockwellautomation:compactlogix_1769-l35e_firmware
rockwellautomationcompactlogix_1769-l32c_firmwarecpe:/o:rockwellautomation:compactlogix_1769-l32c_firmware
rockwellautomationcontrollogix_5550_firmwarecpe:/o:rockwellautomation:controllogix_5550_firmware
rockwellautomationcontrollogix_5570_firmwarecpe:/o:rockwellautomation:controllogix_5570_firmware
rockwellautomationcontrollogix_5560_firmwarecpe:/o:rockwellautomation:controllogix_5560_firmware
rockwellautomationcompactlogix_1769-l31_firmwarecpe:/o:rockwellautomation:compactlogix_1769-l31_firmware
Rows per page:
1-10 of 241

CVSS2

7.5

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

PARTIAL

Integrity Impact

PARTIAL

Availability Impact

PARTIAL

AV:N/AC:L/Au:N/C:P/I:P/A:P

CVSS3

10

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

CHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H

AI Score

9.6

Confidence

High

EPSS

0.001

Percentile

41.5%

Related for TENABLE_OT_ROCKWELL_CVE-2022-1161.NASL