| Reporter | Title | Published | Views | Family All 12 |
|---|---|---|---|---|
| GE Grid Solutions UR 信息泄露漏洞 | 16 Mar 202100:00 | – | cnnvd | |
| CVE-2021-27424 | 23 Mar 202219:46 | – | cve | |
| CVE-2021-27424 GE UR family exposure of sensitive information to an unauthorized actor | 23 Mar 202219:46 | – | cvelist | |
| EUVD-2021-14178 | 7 Oct 202500:30 | – | euvd | |
| GE UR Family (Update A) | 16 Mar 202106:00 | – | ics | |
| CVE-2021-27424 | 23 Mar 202220:15 | – | nvd | |
| CVE-2021-27424 | 23 Mar 202220:15 | – | osv | |
| Information disclosure | 23 Mar 202220:15 | – | prion | |
| CVE-2021-27424 | 22 May 202521:10 | – | redhatcve | |
| Critical Flaws Affecting GE's Universal Relay Pose Threat to Electric Utilities | 23 Mar 202111:24 | – | thn |
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(503349);
script_version("1.2");
script_set_attribute(attribute:"plugin_modification_date", value:"2025/10/01");
script_cve_id("CVE-2021-27424");
script_xref(name:"ICSA", value:"21-075-02");
script_name(english:"GE UR family Exposure of Sensitive Information to an Unauthorized Actor (CVE-2021-27424)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"GE UR firmware versions prior to version 8.1x shares MODBUS memory map
as part of the communications guide. GE was made aware a Last-key
pressed MODBUS register can be used to gain unauthorized information.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02");
script_set_attribute(attribute:"see_also", value:"https://www.gegridsolutions.com/Passport/Login.aspx");
script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.
GE strongly recommends users with impacted firmware versions update their UR devices to UR firmware Version 8.10, or
greater to resolve these vulnerabilities. GE provides additional mitigations and information about these vulnerabilities
in GE Publication Number: GES-2021-004 (login required).
GE recommends protecting UR IED by using network defense-in-depth practices. This includes, but is not limited to,
placing UR IED inside the control system network security perimeter, and having access controls, monitoring (such as an
Intrusion Detection System), and other mitigating technologies in place.
GE recommends users refer to the UR Deployment guide for secure configuration of UR IED and system.");
script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:P/I:N/A:N");
script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2021-27424");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_cwe_id(200);
script_set_attribute(attribute:"vuln_publication_date", value:"2022/03/23");
script_set_attribute(attribute:"patch_publication_date", value:"2022/03/23");
script_set_attribute(attribute:"plugin_publication_date", value:"2025/09/29");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:ge:multilin_b30_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:ge:multilin_b90_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:ge:multilin_c30_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:ge:multilin_c60_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:ge:multilin_c70_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:ge:multilin_c95_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:ge:multilin_d30_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:ge:multilin_d60_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:ge:multilin_f35_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:ge:multilin_f60_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:ge:multilin_g30_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:ge:multilin_g60_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:ge:multilin_l30_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:ge:multilin_l60_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:ge:multilin_l90_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:ge:multilin_m60_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:ge:multilin_n60_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:ge:multilin_t35_firmware");
script_set_attribute(attribute:"cpe", value:"cpe:/o:ge:multilin_t60_firmware");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2025 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/GE");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/GE');
var asset = tenable_ot::assets::get(vendor:'GE');
var vuln_cpes = {
"cpe:/o:ge:multilin_b30_firmware" :
{"versionEndExcluding" : "8.10", "family" : "MultilinUR"},
"cpe:/o:ge:multilin_b90_firmware" :
{"versionEndExcluding" : "8.10", "family" : "MultilinUR"},
"cpe:/o:ge:multilin_c60_firmware" :
{"versionEndExcluding" : "8.10", "family" : "MultilinUR"},
"cpe:/o:ge:multilin_c70_firmware" :
{"versionEndExcluding" : "8.10", "family" : "MultilinUR"},
"cpe:/o:ge:multilin_c95_firmware" :
{"versionEndExcluding" : "8.10", "family" : "MultilinUR"},
"cpe:/o:ge:multilin_d30_firmware" :
{"versionEndExcluding" : "8.10", "family" : "MultilinUR"},
"cpe:/o:ge:multilin_d60_firmware" :
{"versionEndExcluding" : "8.10", "family" : "MultilinUR"},
"cpe:/o:ge:multilin_f35_firmware" :
{"versionEndExcluding" : "8.10", "family" : "MultilinUR"},
"cpe:/o:ge:multilin_f60_firmware" :
{"versionEndExcluding" : "8.10", "family" : "MultilinUR"},
"cpe:/o:ge:multilin_g30_firmware" :
{"versionEndExcluding" : "8.10", "family" : "MultilinUR"},
"cpe:/o:ge:multilin_g60_firmware" :
{"versionEndExcluding" : "8.10", "family" : "MultilinUR"},
"cpe:/o:ge:multilin_l30_firmware" :
{"versionEndExcluding" : "8.10", "family" : "MultilinUR"},
"cpe:/o:ge:multilin_l60_firmware" :
{"versionEndExcluding" : "8.10", "family" : "MultilinUR"},
"cpe:/o:ge:multilin_l90_firmware" :
{"versionEndExcluding" : "8.10", "family" : "MultilinUR"},
"cpe:/o:ge:multilin_m60_firmware" :
{"versionEndExcluding" : "8.10", "family" : "MultilinUR"},
"cpe:/o:ge:multilin_n60_firmware" :
{"versionEndExcluding" : "8.10", "family" : "MultilinUR"},
"cpe:/o:ge:multilin_t35_firmware" :
{"versionEndExcluding" : "8.10", "family" : "MultilinUR"},
"cpe:/o:ge:multilin_t60_firmware" :
{"versionEndExcluding" : "8.10", "family" : "MultilinUR"},
"cpe:/o:ge:multilin_c30_firmware" :
{"versionEndExcluding" : "8.10", "family" : "MultilinUR"}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation