Lucene search

K
nessusThis script is Copyright (C) 2023 and is owned by Tenable, Inc. or an Affiliate thereof.TENABLE_OT_CISCO_CVE-2019-1775.NASL
HistoryJul 25, 2023 - 12:00 a.m.

Cisco NX-OS Software Command Injection (CVE-2019-1775)

2023-07-2500:00:00
This script is Copyright (C) 2023 and is owned by Tenable, Inc. or an Affiliate thereof.
www.tenable.com
6
cisco nx-os
command injection
cve-2019-1775
local attacker
arbitrary commands
insufficient validation
elevated privileges
administrator credentials
tenable.ot
scanner

7.2 High

CVSS2

Attack Vector

LOCAL

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

COMPLETE

Integrity Impact

COMPLETE

Availability Impact

COMPLETE

AV:L/AC:L/Au:N/C:C/I:C/A:C

6.7 Medium

CVSS3

Attack Vector

LOCAL

Attack Complexity

LOW

Privileges Required

HIGH

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

0.0004 Low

EPSS

Percentile

5.2%

A vulnerability in the CLI of Cisco NX-OS Software could allow an authenticated, local attacker to execute arbitrary commands on the underlying operating system of an affected device. This vulnerability is due to insufficient validation of arguments passed to certain CLI commands. An attacker could exploit this vulnerability by including malicious input as the argument of an affected command. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with elevated privileges. An attacker would need valid administrator credentials to exploit this vulnerability.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(501263);
  script_version("1.1");
  script_set_attribute(attribute:"plugin_modification_date", value:"2023/07/26");

  script_cve_id("CVE-2019-1775");

  script_name(english:"Cisco NX-OS Software Command Injection (CVE-2019-1775)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"A vulnerability in the CLI of Cisco NX-OS Software could allow an
authenticated, local attacker to execute arbitrary commands on the
underlying operating system of an affected device. This vulnerability
is due to insufficient validation of arguments passed to certain CLI
commands. An attacker could exploit this vulnerability by including
malicious input as the argument of an affected command. A successful
exploit could allow the attacker to execute arbitrary commands on the
underlying operating system with elevated privileges. An attacker
would need valid administrator credentials to exploit this
vulnerability.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  # https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190515-nxos-cmdinj-1774-1775
  script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?217a964d");
  script_set_attribute(attribute:"see_also", value:"http://www.securityfocus.com/bid/108371");
  script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
  script_set_cvss_base_vector("CVSS2#AV:L/AC:L/Au:N/C:C/I:C/A:C");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2019-1775");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_cwe_id(78);

  script_set_attribute(attribute:"vuln_publication_date", value:"2019/05/15");
  script_set_attribute(attribute:"patch_publication_date", value:"2019/05/15");
  script_set_attribute(attribute:"plugin_publication_date", value:"2023/07/25");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:cisco:nx-os:6");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:cisco:nx-os:7");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:cisco:nx-os:8");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2023 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Cisco");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Cisco');

var asset = tenable_ot::assets::get(vendor:'Cisco');

var vuln_cpes = {
    "cpe:/o:cisco:nx-os:6.2%2825%29" :
        {"versionEndExcluding" : "6.2%2825%29", "versionStartIncluding" : "5.2", "family" : "NXOS"},
    "cpe:/o:cisco:nx-os:8.1%281b%29" :
        {"versionEndExcluding" : "8.1%281b%29", "versionStartIncluding" : "7.3", "family" : "NXOS"},
    "cpe:/o:cisco:nx-os:7.0%283%29i4%289\" :
        {"versionEndExcluding" : "7.0%283%29i4%289%29", "family" : "NXOS"},
    "cpe:/o:cisco:nx-os:7.3%283%29i7%284%29" :
        {"versionEndExcluding" : "7.3%283%29i7%284%29", "versionStartIncluding" : "7.0%283%29i7", "family" : "NXOS"},
    "cpe:/o:cisco:nx-os:6.0%282%29a8%2811%29" :
        {"versionEndExcluding" : "6.0%282%29a8%2811%29", "family" : "NXOS"},
    "cpe:/o:cisco:nx-os:7.0%283%29f3%285%29" :
        {"versionEndExcluding" : "7.0%283%29f3%285%29", "versionStartIncluding" : "7.0%283%29", "family" : "NXOS"},
    "cpe:/o:cisco:nx-os:7.3%284%29n1%281%29" :
        {"versionEndExcluding" : "7.3%284%29n1%281%29", "family" : "NXOS"},
    "cpe:/o:cisco:nx-os:6.2%2822%29" :
        {"versionEndExcluding" : "6.2%2822%29", "family" : "NXOS"},
    "cpe:/o:cisco:nx-os:7.3%283%29d1%281%29" :
        {"versionEndExcluding" : "7.3%283%29d1%281%29", "versionStartIncluding" : "7.2", "family" : "NXOS"},
    "cpe:/o:cisco:nx-os:8.3%281%29" :
        {"versionEndExcluding" : "8.3%281%29", "versionStartIncluding" : "8.0", "family" : "NXOS"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
VendorProductVersionCPE
cisconx-os7cpe:/o:cisco:nx-os:7
cisconx-os6cpe:/o:cisco:nx-os:6
cisconx-os8cpe:/o:cisco:nx-os:8

7.2 High

CVSS2

Attack Vector

LOCAL

Attack Complexity

LOW

Authentication

NONE

Confidentiality Impact

COMPLETE

Integrity Impact

COMPLETE

Availability Impact

COMPLETE

AV:L/AC:L/Au:N/C:C/I:C/A:C

6.7 Medium

CVSS3

Attack Vector

LOCAL

Attack Complexity

LOW

Privileges Required

HIGH

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

0.0004 Low

EPSS

Percentile

5.2%

Related for TENABLE_OT_CISCO_CVE-2019-1775.NASL