Lucene search
K

Cisco NX-OS Exposure of Resource to Wrong Sphere (CVE-2017-12342)

🗓️ 04 Dec 2024 00:00:00Reported by TenableType 
nessus
 nessus
🔗 www.tenable.com👁 7 Views

Vulnerability in Cisco NX-OS allows local attackers to exploit Open Agent Container feature.

Related
Refs
Code
ReporterTitlePublishedViews
Family
Cisco
Cisco Nexus Series Switches Open Agent Container Code Execution Vulnerability
29 Nov 201716:00
cisco
CNVD
Code Execution Vulnerability in Multiple Cisco Products
4 Dec 201700:00
cnvd
CVE
CVE-2017-12342
30 Nov 201709:00
cve
Cvelist
CVE-2017-12342
30 Nov 201709:00
cvelist
EUVD
EUVD-2017-3915
7 Oct 202500:30
euvd
NVD
CVE-2017-12342
30 Nov 201709:29
nvd
OSV
CVE-2017-12342
30 Nov 201709:29
osv
Prion
Design/Logic Flaw
30 Nov 201709:29
prion
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(502746);
  script_version("1.3");
  script_set_attribute(attribute:"plugin_modification_date", value:"2025/10/16");

  script_cve_id("CVE-2017-12342");

  script_name(english:"Cisco NX-OS Exposure of Resource to Wrong Sphere (CVE-2017-12342)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"A vulnerability in the Open Agent Container (OAC) feature of Cisco
Nexus Series Switches could allow an unauthenticated, local attacker
to read and send packets outside the scope of the OAC. The
vulnerability is due to insufficient internal security measures in the
OAC feature. An attacker could exploit this vulnerability by crafting
specific packets for communication on the device-internal network. A
successful exploit could allow the attacker to run code on the
underlying host operating system. OAC is not enabled by default. For a
device to be vulnerable, an administrator would need to install and
activate this feature. This vulnerability affects the following Cisco
Nexus Series Switches: Nexus 2000 Series Fabric Extenders, Nexus 5000
Series Switches, Nexus 5500 Platform Switches, Nexus 5600 Platform
Switches, Nexus 6000 Series Switches, Nexus 7000 Series Switches,
Nexus 7700 Series Switches. Cisco Bug IDs: CSCve53542, CSCvf36621.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  script_set_attribute(attribute:"see_also", value:"http://www.securityfocus.com/bid/102027");
  script_set_attribute(attribute:"see_also", value:"http://www.securitytracker.com/id/1039940");
  # https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20171129-nxos9
  script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?830cf4fc");
  script_set_attribute(attribute:"see_also", value:"http://www.securityfocus.com/bid/102027");
  script_set_attribute(attribute:"see_also", value:"http://www.securitytracker.com/id/1039940");
  # https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20171129-nxos9
  script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?830cf4fc");
  script_set_attribute(attribute:"solution", value:
"Refer to the vendor advisory.");
  script_set_cvss_base_vector("CVSS2#AV:L/AC:L/Au:N/C:P/I:P/A:P");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:L/PR:N/UI:N/S:C/C:L/I:L/A:L");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2017-12342");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");
  script_cwe_id(264, 668);

  script_set_attribute(attribute:"vuln_publication_date", value:"2017/11/30");
  script_set_attribute(attribute:"patch_publication_date", value:"2017/11/30");
  script_set_attribute(attribute:"plugin_publication_date", value:"2024/12/04");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:cisco:nexus_7000_series_switches");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2024-2025 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/Cisco");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/Cisco');

var asset = tenable_ot::assets::get(vendor:'Cisco');

var vuln_cpes = {
    "cpe:/o:cisco:nexus_7000_series_switches" :
        {"versionEndIncluding" : "8.1%281%29", "versionStartIncluding" : "8.1%281%29", "family" : "NXOS"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_WARNING);

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation

16 Oct 2025 00:00Current
6.8Medium risk
Vulners AI Score6.8
CVSS 24.6
CVSS 36.8
EPSS0.00382
7