| Reporter | Title | Published | Views | Family All 10 |
|---|---|---|---|---|
| CVE-2026-1773 | 24 Feb 202617:02 | – | circl | |
| Hitachi Energy RTU500 安全漏洞 | 24 Feb 202600:00 | – | cnnvd | |
| CVE-2026-1773 | 24 Feb 202613:13 | – | cve | |
| CVE-2026-1773 | 24 Feb 202613:13 | – | cvelist | |
| EUVD-2026-8462 | 24 Feb 202613:13 | – | euvd | |
| CVE-2026-1773 | 24 Feb 202614:16 | – | nvd | |
| CVE-2026-1773 | 24 Feb 202614:16 | – | osv | |
| PT-2026-21677 | 24 Feb 202600:00 | – | ptsecurity | |
| CVE-2026-1773 | 25 Feb 202616:16 | – | redhatcve | |
| CVE-2026-1773 | 24 Feb 202613:13 | – | vulnrichment |
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(505207);
script_version("1.5");
script_set_attribute(attribute:"plugin_modification_date", value:"2026/06/17");
script_cve_id("CVE-2026-1773");
script_xref(name:"ICSA", value:"26-062-03");
script_name(english:"Hitachi Energy RTU500 Product Incomplete List of Disallowed Inputs (CVE-2026-1773)");
script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"IEC 60870-5-104: Potential Denial of Service impact on reception of
invalid U-format frame. Product is only affected if IEC 60870-5-104
bi-directional functionality is configured. Enabling secure
communication following IEC 62351-3 does not remediate the
vulnerability but mitigates the risk of exploitation.
This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
# https://publisher.hitachienergy.com/preview?DocumentID=8DBD000237&LanguageCode=en&DocumentPartId=&Action=Launch
script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?c424473c");
script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-26-062-03");
script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.");
script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:N/I:N/A:C");
script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H");
script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
script_set_attribute(attribute:"cvss4_vector", value:"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N");
script_set_attribute(attribute:"cvss4_threat_vector", value:"CVSS:4.0/E:U");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2026-1773");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_set_attribute(attribute:"exploit_available", value:"false");
script_cwe_id(184);
script_set_attribute(attribute:"vuln_publication_date", value:"2026/02/24");
script_set_attribute(attribute:"patch_publication_date", value:"2026/02/24");
script_set_attribute(attribute:"plugin_publication_date", value:"2026/03/04");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu520_firmware:12");
script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu520_firmware:13.5");
script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu520_firmware:13.6");
script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu520_firmware:13.7");
script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu520_firmware:13.8.1");
script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu530_firmware:12");
script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu530_firmware:13.5");
script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu530_firmware:13.6");
script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu530_firmware:13.7");
script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu530_firmware:13.8.1");
script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu540_firmware:12");
script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu540_firmware:13.5");
script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu540_firmware:13.6");
script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu540_firmware:13.7");
script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu540_firmware:13.8.1");
script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu560_firmware:12");
script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu560_firmware:13.5");
script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu560_firmware:13.6");
script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu560_firmware:13.7");
script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu560_firmware:13.8.1");
script_set_attribute(attribute:"generated_plugin", value:"former");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Tenable.ot");
script_copyright(english:"This script is Copyright (C) 2026 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("tenable_ot_api_integration.nasl");
script_require_keys("Tenable.ot/ABB");
exit(0);
}
include('tenable_ot_cve_funcs.inc');
get_kb_item_or_exit('Tenable.ot/ABB');
var asset = tenable_ot::assets::get(vendor:'ABB');
var vuln_cpes = {
"cpe:/o:hitachienergy:rtu540_firmware:12" :
{"versionEndIncluding" : "12.7.7", "versionStartIncluding" : "12.7.1", "family" : "AbbRTU500"},
"cpe:/o:hitachienergy:rtu540_firmware:13.5" :
{"versionEndIncluding" : "13.5.4", "versionStartIncluding" : "13.5.1", "family" : "AbbRTU500"},
"cpe:/o:hitachienergy:rtu540_firmware:13.6" :
{"versionEndIncluding" : "13.6.2", "versionStartIncluding" : "13.6.1", "family" : "AbbRTU500"},
"cpe:/o:hitachienergy:rtu540_firmware:13.7" :
{"versionEndExcluding" : "13.7.8", "versionStartIncluding" : "13.7.1", "family" : "AbbRTU500"},
"cpe:/o:hitachienergy:rtu540_firmware:13.8.1" :
{"versionEndIncluding" : "13.8.1", "versionStartIncluding" : "13.8.1", "family" : "AbbRTU500"},
"cpe:/o:hitachienergy:rtu560_firmware:12" :
{"versionEndIncluding" : "12.7.7", "versionStartIncluding" : "12.7.1", "family" : "AbbRTU500"},
"cpe:/o:hitachienergy:rtu560_firmware:13.5" :
{"versionEndIncluding" : "13.5.4", "versionStartIncluding" : "13.5.1", "family" : "AbbRTU500"},
"cpe:/o:hitachienergy:rtu560_firmware:13.6" :
{"versionEndIncluding" : "13.6.2", "versionStartIncluding" : "13.6.1", "family" : "AbbRTU500"},
"cpe:/o:hitachienergy:rtu560_firmware:13.7" :
{"versionEndExcluding" : "13.7.8", "versionStartIncluding" : "13.7.1", "family" : "AbbRTU500"},
"cpe:/o:hitachienergy:rtu560_firmware:13.8.1" :
{"versionEndIncluding" : "13.8.1", "versionStartIncluding" : "13.8.1", "family" : "AbbRTU500"},
"cpe:/o:hitachienergy:rtu520_firmware:12" :
{"versionEndIncluding" : "12.7.7", "versionStartIncluding" : "12.7.1", "family" : "AbbRTU500"},
"cpe:/o:hitachienergy:rtu520_firmware:13.5" :
{"versionEndIncluding" : "13.5.4", "versionStartIncluding" : "13.5.1", "family" : "AbbRTU500"},
"cpe:/o:hitachienergy:rtu520_firmware:13.6" :
{"versionEndIncluding" : "13.6.2", "versionStartIncluding" : "13.6.1", "family" : "AbbRTU500"},
"cpe:/o:hitachienergy:rtu520_firmware:13.7" :
{"versionEndExcluding" : "13.7.8", "versionStartIncluding" : "13.7.1", "family" : "AbbRTU500"},
"cpe:/o:hitachienergy:rtu520_firmware:13.8.1" :
{"versionEndIncluding" : "13.8.1", "versionStartIncluding" : "13.8.1", "family" : "AbbRTU500"},
"cpe:/o:hitachienergy:rtu530_firmware:12" :
{"versionEndIncluding" : "12.7.7", "versionStartIncluding" : "12.7.1", "family" : "AbbRTU500"},
"cpe:/o:hitachienergy:rtu530_firmware:13.5" :
{"versionEndIncluding" : "13.5.4", "versionStartIncluding" : "13.5.1", "family" : "AbbRTU500"},
"cpe:/o:hitachienergy:rtu530_firmware:13.6" :
{"versionEndIncluding" : "13.6.2", "versionStartIncluding" : "13.6.1", "family" : "AbbRTU500"},
"cpe:/o:hitachienergy:rtu530_firmware:13.7" :
{"versionEndExcluding" : "13.7.8", "versionStartIncluding" : "13.7.1", "family" : "AbbRTU500"},
"cpe:/o:hitachienergy:rtu530_firmware:13.8.1" :
{"versionEndIncluding" : "13.8.1", "versionStartIncluding" : "13.8.1", "family" : "AbbRTU500"}
};
tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation