Lucene search
K

Hitachi Energy RTU500 Product Incomplete List of Disallowed Inputs (CVE-2026-1773)

🗓️ 04 Mar 2026 00:00:00Reported by TenableType 
nessus
 nessus
🔗 www.tenable.com👁 4 Views

ABB RTU500 denial of service from invalid U-format frames with bi-directional IEC 60870-5-104.

Related
Refs
Code
ReporterTitlePublishedViews
Family
Circl
CVE-2026-1773
24 Feb 202617:02
circl
CNNVD
Hitachi Energy RTU500 安全漏洞
24 Feb 202600:00
cnnvd
CVE
CVE-2026-1773
24 Feb 202613:13
cve
Cvelist
CVE-2026-1773
24 Feb 202613:13
cvelist
EUVD
EUVD-2026-8462
24 Feb 202613:13
euvd
NVD
CVE-2026-1773
24 Feb 202614:16
nvd
OSV
CVE-2026-1773
24 Feb 202614:16
osv
Positive Technologies
PT-2026-21677
24 Feb 202600:00
ptsecurity
RedhatCVE
CVE-2026-1773
25 Feb 202616:16
redhatcve
Vulnrichment
CVE-2026-1773
24 Feb 202613:13
vulnrichment
Rows per page
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(505207);
  script_version("1.5");
  script_set_attribute(attribute:"plugin_modification_date", value:"2026/06/17");

  script_cve_id("CVE-2026-1773");
  script_xref(name:"ICSA", value:"26-062-03");

  script_name(english:"Hitachi Energy RTU500 Product Incomplete List of Disallowed Inputs (CVE-2026-1773)");

  script_set_attribute(attribute:"synopsis", value:
"The remote OT asset is affected by a vulnerability.");
  script_set_attribute(attribute:"description", value:
"IEC 60870-5-104: Potential Denial of Service impact on reception of
invalid U-format frame. Product is only affected if IEC 60870-5-104
bi-directional functionality is configured. Enabling secure
communication following IEC 62351-3 does not remediate the
vulnerability but mitigates the risk of exploitation.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.");
  # https://publisher.hitachienergy.com/preview?DocumentID=8DBD000237&LanguageCode=en&DocumentPartId=&Action=Launch
  script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?c424473c");
  script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-26-062-03");
  script_set_attribute(attribute:"solution", value:
"The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original
can be found at CISA.gov.");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:N/I:N/A:C");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss4_vector", value:"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N");
  script_set_attribute(attribute:"cvss4_threat_vector", value:"CVSS:4.0/E:U");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2026-1773");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");
  script_cwe_id(184);

  script_set_attribute(attribute:"vuln_publication_date", value:"2026/02/24");
  script_set_attribute(attribute:"patch_publication_date", value:"2026/02/24");
  script_set_attribute(attribute:"plugin_publication_date", value:"2026/03/04");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu520_firmware:12");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu520_firmware:13.5");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu520_firmware:13.6");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu520_firmware:13.7");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu520_firmware:13.8.1");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu530_firmware:12");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu530_firmware:13.5");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu530_firmware:13.6");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu530_firmware:13.7");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu530_firmware:13.8.1");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu540_firmware:12");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu540_firmware:13.5");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu540_firmware:13.6");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu540_firmware:13.7");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu540_firmware:13.8.1");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu560_firmware:12");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu560_firmware:13.5");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu560_firmware:13.6");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu560_firmware:13.7");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:hitachienergy:rtu560_firmware:13.8.1");
  script_set_attribute(attribute:"generated_plugin", value:"former");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Tenable.ot");

  script_copyright(english:"This script is Copyright (C) 2026 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("tenable_ot_api_integration.nasl");
  script_require_keys("Tenable.ot/ABB");

  exit(0);
}


include('tenable_ot_cve_funcs.inc');

get_kb_item_or_exit('Tenable.ot/ABB');

var asset = tenable_ot::assets::get(vendor:'ABB');

var vuln_cpes = {
    "cpe:/o:hitachienergy:rtu540_firmware:12" :
        {"versionEndIncluding" : "12.7.7", "versionStartIncluding" : "12.7.1", "family" : "AbbRTU500"},
    "cpe:/o:hitachienergy:rtu540_firmware:13.5" :
        {"versionEndIncluding" : "13.5.4", "versionStartIncluding" : "13.5.1", "family" : "AbbRTU500"},
    "cpe:/o:hitachienergy:rtu540_firmware:13.6" :
        {"versionEndIncluding" : "13.6.2", "versionStartIncluding" : "13.6.1", "family" : "AbbRTU500"},
    "cpe:/o:hitachienergy:rtu540_firmware:13.7" :
        {"versionEndExcluding" : "13.7.8", "versionStartIncluding" : "13.7.1", "family" : "AbbRTU500"},
    "cpe:/o:hitachienergy:rtu540_firmware:13.8.1" :
        {"versionEndIncluding" : "13.8.1", "versionStartIncluding" : "13.8.1", "family" : "AbbRTU500"},
    "cpe:/o:hitachienergy:rtu560_firmware:12" :
        {"versionEndIncluding" : "12.7.7", "versionStartIncluding" : "12.7.1", "family" : "AbbRTU500"},
    "cpe:/o:hitachienergy:rtu560_firmware:13.5" :
        {"versionEndIncluding" : "13.5.4", "versionStartIncluding" : "13.5.1", "family" : "AbbRTU500"},
    "cpe:/o:hitachienergy:rtu560_firmware:13.6" :
        {"versionEndIncluding" : "13.6.2", "versionStartIncluding" : "13.6.1", "family" : "AbbRTU500"},
    "cpe:/o:hitachienergy:rtu560_firmware:13.7" :
        {"versionEndExcluding" : "13.7.8", "versionStartIncluding" : "13.7.1", "family" : "AbbRTU500"},
    "cpe:/o:hitachienergy:rtu560_firmware:13.8.1" :
        {"versionEndIncluding" : "13.8.1", "versionStartIncluding" : "13.8.1", "family" : "AbbRTU500"},
    "cpe:/o:hitachienergy:rtu520_firmware:12" :
        {"versionEndIncluding" : "12.7.7", "versionStartIncluding" : "12.7.1", "family" : "AbbRTU500"},
    "cpe:/o:hitachienergy:rtu520_firmware:13.5" :
        {"versionEndIncluding" : "13.5.4", "versionStartIncluding" : "13.5.1", "family" : "AbbRTU500"},
    "cpe:/o:hitachienergy:rtu520_firmware:13.6" :
        {"versionEndIncluding" : "13.6.2", "versionStartIncluding" : "13.6.1", "family" : "AbbRTU500"},
    "cpe:/o:hitachienergy:rtu520_firmware:13.7" :
        {"versionEndExcluding" : "13.7.8", "versionStartIncluding" : "13.7.1", "family" : "AbbRTU500"},
    "cpe:/o:hitachienergy:rtu520_firmware:13.8.1" :
        {"versionEndIncluding" : "13.8.1", "versionStartIncluding" : "13.8.1", "family" : "AbbRTU500"},
    "cpe:/o:hitachienergy:rtu530_firmware:12" :
        {"versionEndIncluding" : "12.7.7", "versionStartIncluding" : "12.7.1", "family" : "AbbRTU500"},
    "cpe:/o:hitachienergy:rtu530_firmware:13.5" :
        {"versionEndIncluding" : "13.5.4", "versionStartIncluding" : "13.5.1", "family" : "AbbRTU500"},
    "cpe:/o:hitachienergy:rtu530_firmware:13.6" :
        {"versionEndIncluding" : "13.6.2", "versionStartIncluding" : "13.6.1", "family" : "AbbRTU500"},
    "cpe:/o:hitachienergy:rtu530_firmware:13.7" :
        {"versionEndExcluding" : "13.7.8", "versionStartIncluding" : "13.7.1", "family" : "AbbRTU500"},
    "cpe:/o:hitachienergy:rtu530_firmware:13.8.1" :
        {"versionEndIncluding" : "13.8.1", "versionStartIncluding" : "13.8.1", "family" : "AbbRTU500"}
};

tenable_ot::cve::compare_and_report(asset:asset, cpes:vuln_cpes, severity:SECURITY_HOLE);

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation

17 Jun 2026 00:00Current
5.2Medium risk
Vulners AI Score5.2
CVSS 3.17.5
CVSS 48.7
EPSS0.00411
SSVC
4