Lucene search
+L

Rockwell FactoryTalk Services Platform 6.60 Authentication Bypass (SD1786)

🗓️ 24 Jul 2026 00:00:00Reported by TenableType 
nessus
 nessus
🔗 www.tenable.com👁 5 Views

Rockwell FactoryTalk Services Platform 6.60 has a JWT bypass enabling impersonation.

Related
Refs
Code
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(329329);
  script_version("1.2");
  script_set_attribute(attribute:"plugin_modification_date", value:"2026/07/27");

  script_cve_id("CVE-2026-10714");
  script_xref(name:"IAVA", value:"2026-B-0200");

  script_name(english:"Rockwell FactoryTalk Services Platform 6.60 Authentication Bypass (SD1786)");

  script_set_attribute(attribute:"synopsis", value:
"An application installed on the remote Windows host is affected by an authentication bypass vulnerability.");
  script_set_attribute(attribute:"description", value:
"The version of Rockwell FactoryTalk Services Platform installed on the remote Windows host is 6.60. It is, therefore,
affected by an authentication bypass vulnerability:

  - A vulnerability exists that allows an attacker to bypass JWT signature validation during Okta Web Authentication.
    The application does not verify that the JWT algorithm is configured for RSA, enabling an attacker to set the
    algorithm to 'none' and craft forged tokens. This could allow an authenticated low-privilege user to impersonate
    any authorized user on the FTSP server, resulting in unauthorized access to system configuration and the ability to
    grant permissions to other systems protected by FTSP. (CVE-2026-10714)

Note that Nessus has not tested for this issue but has instead relied only on the application's self-reported version
number. The fix for this vulnerability is a patch applied to an existing version, which Nessus is unable to detect.");
  # https://www.rockwellautomation.com/en-in/trust-center/security-advisories/advisory.SD1786.html
  script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?4fcac294");
  script_set_attribute(attribute:"solution", value:
"Apply patch RAID 1158263 or refer to vendor advisory SD1786.");
  script_set_cvss_base_vector("CVSS2#AV:L/AC:H/Au:S/C:C/I:C/A:C");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss4_vector", value:"CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H");
  script_set_attribute(attribute:"cvss4_threat_vector", value:"CVSS:4.0/E:U");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2026-10714");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");

  script_set_attribute(attribute:"vuln_publication_date", value:"2026/07/14");
  script_set_attribute(attribute:"patch_publication_date", value:"2026/07/14");
  script_set_attribute(attribute:"plugin_publication_date", value:"2026/07/24");

  script_set_attribute(attribute:"plugin_type", value:"local");
  script_set_attribute(attribute:"cpe", value:"cpe:/a:rockwellautomation:factorytalk_services_platform");
  script_set_attribute(attribute:"stig_severity", value:"I");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"SCADA");

  script_copyright(english:"This script is Copyright (C) 2026 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("rockwell_factorytalk_services_platform_win_installed.nbin");
  script_require_keys("installed_sw/Rockwell FactoryTalk Services Platform", "SMB/Registry/Enumerated");

  exit(0);
}

include('vcf.inc');

var app_info = vcf::get_app_info(app:'Rockwell FactoryTalk Services Platform', win_local:TRUE);

var constraints = [
  {'equal': '6.60', 'fixed_display': 'Apply patch RAID 1158263 (see vendor advisory SD1786)', 'require_paranoia': TRUE}
];

vcf::check_version_and_report(app_info:app_info, constraints:constraints, severity:SECURITY_WARNING);

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation

27 Jul 2026 00:00Current
7.1High risk
Vulners AI Score7.1
CVSS 48.8
EPSS0.00113
SSVC
5