| Reporter | Title | Published | Views | Family All 11 |
|---|---|---|---|---|
| The vulnerability of FactoryTalk Batch View’s software for real-time control and monitoring processes is related to deficiencies in authentication procedures, allowing attackers to circumvent existing security restrictions. | 17 Sep 202400:00 | – | bdu_fstec | |
| CVE-2024-45823 | 12 Sep 202417:42 | – | circl | |
| Rockwell Automation FactoryTalk Batch View 安全漏洞 | 12 Sep 202400:00 | – | cnnvd | |
| CVE-2024-45823 | 12 Sep 202414:20 | – | cve | |
| CVE-2024-45823 FactoryTalk® Batch View™ Authentication Bypass Vulnerability via shared secrets | 12 Sep 202414:20 | – | cvelist | |
| EUVD-2024-41617 | 3 Oct 202520:07 | – | euvd | |
| Rockwell Automation FactoryTalk Batch View | 12 Sep 202406:00 | – | ics | |
| CVE-2024-45823 | 12 Sep 202415:18 | – | nvd | |
| CVE-2024-45823 | 12 Sep 202415:18 | – | osv | |
| PT-2024-6220 · Rockwell Automation · Factorytalk Batch View | 12 Sep 202400:00 | – | ptsecurity |
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(207520);
script_version("1.4");
script_set_attribute(attribute:"plugin_modification_date", value:"2025/01/30");
script_cve_id("CVE-2024-45823");
script_xref(name:"ICSA", value:"24-256-22");
script_xref(name:"IAVA", value:"2024-A-0586-S");
script_name(english:"Rockwell FactoryTalk Batch View < 3.00 Authentication Bypass");
script_set_attribute(attribute:"synopsis", value:
"An application installed on the remote Windows host is affected by a vulnerability.");
script_set_attribute(attribute:"description", value:
"The version of Rockwell FactoryTalk Batch View installed on the remote Windows host is prior to 3.00. It is, therefore,
affected by a vulnerability.
- An authentication bypass vulnerability exists in the affected product. The
vulnerability exists due to shared secrets across accounts and could allow a
threat actor to impersonate a user if the threat actor is able to enumerate
additional information required during authentication. (CVE-2024-45823)
Note that Nessus has not tested for this issue but has instead relied only on the application's self-reported version
number.");
# https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD%201698.html
script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?7f447a14");
script_set_attribute(attribute:"see_also", value:"https://www.cisa.gov/news-events/ics-advisories/icsa-24-256-22");
script_set_attribute(attribute:"solution", value:
"Upgrade to Rockwell FactoryTalk Batch View version 3.00 or later.");
script_set_attribute(attribute:"agent", value:"windows");
script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:C/I:C/A:C");
script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H");
script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
script_set_attribute(attribute:"cvss4_vector", value:"CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N");
script_set_attribute(attribute:"cvss4_threat_vector", value:"CVSS:4.0/E:U");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2024-45823");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_set_attribute(attribute:"exploit_available", value:"false");
script_set_attribute(attribute:"vuln_publication_date", value:"2024/09/12");
script_set_attribute(attribute:"patch_publication_date", value:"2024/09/12");
script_set_attribute(attribute:"plugin_publication_date", value:"2024/09/20");
script_set_attribute(attribute:"plugin_type", value:"local");
script_set_attribute(attribute:"cpe", value:"x-cpe:/a:rockwellautomation:factorytalk_batch_view");
script_set_attribute(attribute:"stig_severity", value:"I");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"SCADA");
script_copyright(english:"This script is Copyright (C) 2024-2025 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("rockwell_factorytalk_batch_view_installed.nbin");
script_require_keys("installed_sw/Rockwell FactoryTalk Batch View");
exit(0);
}
include('vcf.inc');
var app_info = vcf::get_app_info(app:'Rockwell FactoryTalk Batch View', win_local:TRUE);
var constraints = [
{'fixed_version' : '3.00.00' }
];
vcf::check_version_and_report(app_info:app_info, constraints:constraints, severity:SECURITY_HOLE);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation