The version of Streamline NX Client installed on the remote host is prior to 3.4.3.2, 3.5.1.202, 3.6.2.2, or 3.7.2.1. It is, therefore, affected by a vulnerability as referenced in the 2024-000005 advisory.
Note that Nessus has not tested for this issue but has instead relied only on the application’s self-reported version number.
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(200809);
script_version("1.2");
script_set_attribute(attribute:"plugin_modification_date", value:"2024/06/24");
script_cve_id("CVE-2024-36480");
script_xref(name:"IAVB", value:"2024-B-0081");
script_name(english:"Streamline NX Client < 3.4.3.2 / 3.5.x < 3.5.1.202 / 3.6.x < 3.6.2.2 / 3.7.x < 3.7.2.1 Privilege Escalation (2024-000005)");
script_set_attribute(attribute:"synopsis", value:
"The remote host is missing a security update.");
script_set_attribute(attribute:"description", value:
"The version of Streamline NX Client installed on the remote host is prior to 3.4.3.2, 3.5.1.202, 3.6.2.2, or 3.7.2.1. It
is, therefore, affected by a vulnerability as referenced in the 2024-000005 advisory.
- Use of hard-coded credentials issue exists in Ricoh Streamline NX PC Client ver.3.7.2 and earlier. If this
vulnerability is exploited, an attacker may obtain LocalSystem Account of the PC where the product is
installed. As a result, unintended operations may be performed on the PC.
Note that Nessus has not tested for this issue but has instead relied only on the application's self-reported version
number.");
# https://www.ricoh.com/products/security/vulnerabilities/vul?id=ricoh-2024-000005
script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?52ec9dfe");
# https://www.ricoh.com/products/security/vulnerabilities/adv?id=ricoh-prod000077-2024-000005
script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?360f166c");
script_set_attribute(attribute:"solution", value:
"Upgrade to Streamline NX Client version 3.4.3.2 / 3.5.1.202 / 3.6.2.2 / 3.7.2.1 or later.");
script_set_attribute(attribute:"agent", value:"windows");
script_set_cvss_base_vector("CVSS2#AV:L/AC:H/Au:N/C:C/I:N/A:N");
script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N");
script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2024-36480");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_set_attribute(attribute:"exploit_available", value:"false");
script_set_attribute(attribute:"vuln_publication_date", value:"2024/06/18");
script_set_attribute(attribute:"patch_publication_date", value:"2024/06/18");
script_set_attribute(attribute:"plugin_publication_date", value:"2024/06/21");
script_set_attribute(attribute:"plugin_type", value:"local");
script_set_attribute(attribute:"cpe", value:"cpe:/a:ricoh:streamline_nx_client_tool");
script_set_attribute(attribute:"stig_severity", value:"II");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Windows");
script_copyright(english:"This script is Copyright (C) 2024 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("ricoh_streamline_nx_win_installed.nbin");
script_require_keys("installed_sw/Streamline NX Client");
exit(0);
}
include('vcf.inc');
var app_info = vcf::get_app_info(app:'Streamline NX Client');
var constraints = [
{ 'min_version' : '0.0', 'fixed_version' : '3.4.3.2' },
{ 'min_version' : '3.5', 'fixed_version' : '3.5.1.202' },
{ 'min_version' : '3.6', 'fixed_version' : '3.6.2.2' },
{ 'min_version' : '3.7', 'fixed_version' : '3.7.2.1' }
];
vcf::check_version_and_report(
app_info:app_info,
constraints:constraints,
severity:SECURITY_WARNING
);
Vendor | Product | Version | CPE |
---|---|---|---|
ricoh | streamline_nx_client_tool | cpe:/a:ricoh:streamline_nx_client_tool |