Lucene search
K

Juniper Junos OS Vulnerability (JSA103144)

🗓️ 08 Oct 2025 00:00:00Reported by TenableType 
nessus
 nessus
🔗 www.tenable.com👁 2 Views

Junos OS Evolved PTX devices face DoS from resource use in connectivity fault management.

Related
Refs
Code
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(269751);
  script_version("1.2");
  script_set_attribute(attribute:"plugin_modification_date", value:"2025/10/17");

  script_cve_id("CVE-2025-52961");
  script_xref(name:"JSA", value:"JSA103144");
  script_xref(name:"IAVA", value:"2025-A-0740");

  script_name(english:"Juniper Junos OS Vulnerability (JSA103144)");

  script_set_attribute(attribute:"synopsis", value:
"The remote device is missing a vendor-supplied security patch.");
  script_set_attribute(attribute:"description", value:
"The version of Junos OS installed on the remote host is affected by a vulnerability as referenced in the JSA103144
advisory.

  - An Uncontrolled Resource Consumption vulnerability in the Connectivity Fault Management (CFM) daemon and
    the Connectivity Fault Management Manager (cfmman) of Juniper Networks Junos OS Evolved on PTX10001-36MR,
    PTX10002-36QDD, PTX10004, PTX10008, PTX10016 allows an unauthenticated, adjacent attacker to cause a
    Denial-of-Service (DoS). (CVE-2025-52961)

Note that Nessus has not tested for these issues but has instead relied only on the application's self-reported version
number.");
  # https://www.juniper.net/documentation/us/en/software/junos/network-mgmt/topics/topic-map/cfm-configuring.html
  script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?432e49a9");
  # https://supportportal.juniper.net/s/article/2025-10-Security-Bulletin-Junos-OS-Evolved-PTX-Series-except-PTX10003-An-unauthenticated-adjacent-attacker-sending-specific-valid-traffic-can-cause-a-memory-leak-in-cfmman-leading-to-FPC-crash-and-restart-CVE-2025-52961
  script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?90e61bf0");
  script_set_attribute(attribute:"solution", value:
"Apply the relevant Junos software release referenced in Juniper advisory JSA103144");
  script_set_cvss_base_vector("CVSS2#AV:A/AC:L/Au:N/C:N/I:N/A:C");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss4_vector", value:"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H");
  script_set_attribute(attribute:"cvss4_supplemental", value:"CVSS:4.0/AU:Y/R:A/V:C/RE:M/U:Green");
  script_set_attribute(attribute:"cvss4_threat_vector", value:"CVSS:4.0/E:U");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2025-52961");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");

  script_set_attribute(attribute:"vuln_publication_date", value:"2025/10/08");
  script_set_attribute(attribute:"patch_publication_date", value:"2025/10/08");
  script_set_attribute(attribute:"plugin_publication_date", value:"2025/10/08");

  script_set_attribute(attribute:"plugin_type", value:"combined");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:juniper:junos");
  script_set_attribute(attribute:"generated_plugin", value:"current");
  script_set_attribute(attribute:"stig_severity", value:"I");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Junos Local Security Checks");

  script_copyright(english:"This script is Copyright (C) 2025 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("junos_version.nasl");
  script_require_keys("Host/Juniper/JUNOS/Version", "Host/Juniper/model");

  exit(0);
}

include('junos.inc');

var model = get_kb_item_or_exit('Host/Juniper/model');
if (model !~ "^PTX10001")
{
  audit(AUDIT_DEVICE_NOT_VULN, model);
}

var ver = get_kb_item_or_exit('Host/Juniper/JUNOS/Version');

var vuln_ranges = [
  {'min_ver':'23.2R1-EVO', 'fixed_ver':'23.2R2-S4-EVO', 'model':'^PTX10001'},
  {'min_ver':'23.4-EVO', 'fixed_ver':'23.4R2-S4-EVO', 'model':'^PTX10001'},
  {'min_ver':'24.2-EVO', 'fixed_ver':'24.2R2-EVO', 'model':'^PTX10001'},
  {'min_ver':'24.4-EVO', 'fixed_ver':'24.4R1-S2-EVO', 'model':'^PTX10001', 'fixed_display':'24.4R1-S2-EVO, 24.4R2-EVO'}
];

var fix = junos_compare_range(target_version:ver, vuln_ranges:vuln_ranges);
if (empty_or_null(fix)) audit(AUDIT_INST_VER_NOT_VULN, 'Junos OS', ver);
var report = get_report(ver:ver, fix:fix);
security_report_v4(severity:SECURITY_WARNING, port:0, extra:report);

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation