Lucene search

K
nessusThis script is Copyright (C) 2023 and is owned by Tenable, Inc. or an Affiliate thereof.INTEL_SA_00717_CVE-2022-30539.NASL
HistoryDec 19, 2023 - 12:00 a.m.

Intel BIOS Firmware CVE-2022-30539 (INTEL-SA-00717)

2023-12-1900:00:00
This script is Copyright (C) 2023 and is owned by Tenable, Inc. or an Affiliate thereof.
www.tenable.com
13
intel bios
firmware vulnerability
cve-2022-30539
intel-sa-00717
use after free
privilege escalation

7.5 High

CVSS3

Attack Vector

LOCAL

Attack Complexity

HIGH

Privileges Required

HIGH

User Interaction

NONE

Scope

CHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H

8 High

AI Score

Confidence

High

0.0004 Low

EPSS

Percentile

9.1%

The version of the Intel BIOS on the remote device is affected by a vulnerability as identified in the INTEL-SA-00717 advisory.

  • Use after free in the BIOS firmware for some Intelยฎ Processors may allow a privileged user to potentially enable escalation of privilege via local access. (CVE-2022-30539)

Note that Nessus has not tested for this issue but has instead relied only on the applicationโ€™s self-reported version number.

#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##

include('compat.inc');

if (description)
{
  script_id(187102);
  script_version("1.1");
  script_set_attribute(attribute:"plugin_modification_date", value:"2023/12/21");

  script_cve_id("CVE-2022-30539");

  script_name(english:"Intel BIOS Firmware CVE-2022-30539 (INTEL-SA-00717)");

  script_set_attribute(attribute:"synopsis", value:
"The BIOS firmware on the remote host is affected by CVE-2022-30539.");
  script_set_attribute(attribute:"description", value:
"The version of the Intel BIOS on the remote device is affected by a vulnerability as identified in the INTEL-SA-00717
advisory.

  - Use after free in the BIOS firmware for some Intel(R) Processors may allow a privileged user to
    potentially enable escalation of privilege via local access. (CVE-2022-30539)

Note that Nessus has not tested for this issue but has instead relied only on the application's self-reported version
number.");
  # https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00717.html
  script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?d5385b3b");
  script_set_attribute(attribute:"solution", value:
"Contact your system OEM for updated firmware per the vendor advisory.");
  script_set_cvss_base_vector("CVSS2#AV:L/AC:L/Au:M/C:C/I:C/A:C");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2022-30539");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");
  script_set_attribute(attribute:"vendor_severity", value:"HIGH");

  script_set_attribute(attribute:"vuln_publication_date", value:"2023/02/14");
  script_set_attribute(attribute:"patch_publication_date", value:"2023/02/14");
  script_set_attribute(attribute:"plugin_publication_date", value:"2023/12/19");

  script_set_attribute(attribute:"potential_vulnerability", value:"true");
  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"generated_plugin", value:"current");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Misc.");

  script_copyright(english:"This script is Copyright (C) 2023 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("intel_cpuid_detection.nbin");
  script_require_keys("SMB/WMI/Available", "Settings/ParanoidReport");

  exit(0);
}

if (report_paranoia < 2) audit(AUDIT_PARANOID);

var processor_id = get_kb_item_or_exit('Host/cpu/cpuid');

var vuln_processors = [
  {
    'Product Collection': '3rd Generation Intel Xeon Scalable Processor Family',
    'Vertical Segment': 'Server',
    'CPU ID': [
      '5065B'
    ],
    'CVE ID': 'CVE-2022-30539',
    'Platform ID': 'BF'
  }
];

var cpuids, report = FALSE;
foreach (var processor in vuln_processors)
{
  cpuids = processor['CPU ID'];
  foreach (var cpuid in cpuids)
  {
    if (processor_id == cpuid)
    {
      report  = 'Installed CPU ID : ' + cpuid + '\n';
      report += 'Installed CPU(s) : ' + processor['Product Collection'] + '\n';
      security_report_v4(port:135, severity:SECURITY_WARNING, extra:report);
      exit(0);
    }
  }
}

audit(AUDIT_INST_VER_NOT_VULN, 'The Intelร‚ยฎ processor');

7.5 High

CVSS3

Attack Vector

LOCAL

Attack Complexity

HIGH

Privileges Required

HIGH

User Interaction

NONE

Scope

CHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H

8 High

AI Score

Confidence

High

0.0004 Low

EPSS

Percentile

9.1%

Related for INTEL_SA_00717_CVE-2022-30539.NASL