Lucene search

K
nessusThis script is Copyright (C) 2017-2022 and is owned by Tenable, Inc. or an Affiliate thereof.HP_IMC_73_E0501P01.NASL
HistoryOct 11, 2017 - 12:00 a.m.

H3C / HPE Intelligent Management Center PLAT <= 7.3 E0501P01 Multiple Vulnerabilities

2017-10-1100:00:00
This script is Copyright (C) 2017-2022 and is owned by Tenable, Inc. or an Affiliate thereof.
www.tenable.com
59

CVSS2

6.8

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

SINGLE

Confidentiality Impact

COMPLETE

Integrity Impact

NONE

Availability Impact

NONE

AV:N/AC:L/Au:S/C:C/I:N/A:N

CVSS3

6.5

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

LOW

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

NONE

Availability Impact

NONE

CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N

EPSS

0.001

Percentile

40.2%

The version of HPE Intelligent Management Center (iMC) PLAT installed on the remote host is prior (or equal) to 7.3 E0501P01. It is, therefore, affected by multiple vulnerabilities which can be exploited to download files or disclose information.

Note that Intelligent Management Center (iMC) is an HPE product;
however, it is branded as H3C.

#%NASL_MIN_LEVEL 70300
#
# (C) Tenable Network Security, Inc.
#

include('deprecated_nasl_level.inc');
include('compat.inc');

if (description)
{
  script_id(103787);
  script_version("1.7");
  script_set_attribute(attribute:"plugin_modification_date", value:"2022/04/11");

  script_cve_id("CVE-2017-12555");
  script_bugtraq_id(101202);
  script_xref(name:"HP", value:"emr_na-hpesbhf03786en_us");
  script_xref(name:"HP", value:"HPESBHF03786");

  script_name(english:"H3C / HPE Intelligent Management Center PLAT <= 7.3 E0501P01 Multiple Vulnerabilities");

  script_set_attribute(attribute:"synopsis", value:
"An application installed on the remote host is affected by
multiple vulnerabilities.");
  script_set_attribute(attribute:"description", value:
"The version of HPE Intelligent Management Center (iMC) PLAT installed
on the remote host is prior (or equal) to 7.3 E0501P01. It is, 
therefore, affected by multiple vulnerabilities which can be
exploited to download files or disclose information.

Note that Intelligent Management Center (iMC) is an HPE product;
however, it is branded as H3C.");
  # https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-hpesbhf03776en_us
  script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?1084fa10");
  script_set_attribute(attribute:"solution", value:
"Upgrade to H3C / HPE iMC version 7.3 E0501P01 or later.");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:S/C:C/I:N/A:N");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2017-12555");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_set_attribute(attribute:"exploit_available", value:"false");

  script_set_attribute(attribute:"vuln_publication_date", value:"2017/10/05");
  script_set_attribute(attribute:"patch_publication_date", value:"2017/10/05");
  script_set_attribute(attribute:"plugin_publication_date", value:"2017/10/11");

  script_set_attribute(attribute:"plugin_type", value:"remote");
  script_set_attribute(attribute:"cpe", value:"cpe:/a:hp:intelligent_management_center");
  script_set_attribute(attribute:"thorough_tests", value:"true");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"Misc.");

  script_copyright(english:"This script is Copyright (C) 2017-2022 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("hp_imc_detect.nbin");
  script_require_ports("Services/activemq", 61616);

  exit(0);
}

include("audit.inc");
include("global_settings.inc");
include("misc_func.inc");

# Figure out which port to use
port = get_service(svc:'activemq', default:61616, exit_on_fail:TRUE);
version = get_kb_item_or_exit('hp/hp_imc/'+port+'/version');

app = 'HP Intelligent Management Center';

fixed_display = '7.3-E0501P01';

fix = "7.3";
patchfix = NULL;

# check patch version if 7.3
if (version =~ "^7.[0-3]\-")
{
  # Versions < 7.3 E0501, remove letters and dashes in version
  patch = pregmatch(pattern:"[0-9.]+-E([0-9A-Z]+)", string:version);
  if (!patch) audit(AUDIT_UNKNOWN_APP_VER, app);
  patchver = ereg_replace(string:patch[1], pattern:"[A-Z\-]", replace:".");
  if (!patchver) audit(AUDIT_UNKNOWN_APP_VER, app);

  patchfix = "0501.01";
}

# if pre 7.3 or 7.3 with patchver before 0501
if ((ver_compare(ver:version, fix:fix, strict:FALSE) < 0) ||
    (!isnull(patchfix) && ver_compare(ver:patchver, fix:patchfix, strict:FALSE) < 0))
{
  items = make_array(
    "Installed version", version,
    "Fixed version", fixed_display
  );

  order = make_list("Installed version", "Fixed version");
  report = report_items_str(report_items:items, ordered_fields:order);

  security_report_v4(port:port, extra:report, severity:SECURITY_WARNING);
  exit(0);
}
else
  audit(AUDIT_INST_VER_NOT_VULN, app, version);

CVSS2

6.8

Attack Vector

NETWORK

Attack Complexity

LOW

Authentication

SINGLE

Confidentiality Impact

COMPLETE

Integrity Impact

NONE

Availability Impact

NONE

AV:N/AC:L/Au:S/C:C/I:N/A:N

CVSS3

6.5

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

LOW

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

NONE

Availability Impact

NONE

CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N

EPSS

0.001

Percentile

40.2%

Related for HP_IMC_73_E0501P01.NASL