Lucene search
K

HP-UX PHSS_28683 : HP-UX running CDE, Remote Unauthorized Privileged Access, Execution of Arbitrary Code (HPSBUX00263 SSRT2373 rev.3)

🗓️ 18 Mar 2005 00:00:00Reported by TenableType 
nessus
 nessus
🔗 www.tenable.com👁 14 Views

HP-UX PHSS_28683 : HP-UX running CDE, Remote Unauthorized Privileged Access, Execution of Arbitrary Code (HPSBUX00263 SSRT2373 rev.3

Refs
Code
SourceLink
nessuswww.nessus.org/u
#%NASL_MIN_LEVEL 70300
#
# (C) Tenable Network Security, Inc.
#
# The descriptive text and patch checks in this plugin were 
# extracted from HP patch PHSS_28683. The text itself is
# copyright (C) Hewlett-Packard Development Company, L.P.
#

include('deprecated_nasl_level.inc');
include('compat.inc');

if (description)
{
  script_id(17496);
  script_version("1.12");
  script_set_attribute(attribute:"plugin_modification_date", value:"2021/01/11");

  script_xref(name:"HP", value:"emr_na-c00957810");
  script_xref(name:"HP", value:"HPSBUX00263");
  script_xref(name:"HP", value:"SSRT2373");

  script_name(english:"HP-UX PHSS_28683 : HP-UX running CDE, Remote Unauthorized Privileged Access, Execution of Arbitrary Code (HPSBUX00263 SSRT2373 rev.3)");
  script_summary(english:"Checks for the patch in the swlist output");

  script_set_attribute(
    attribute:"synopsis", 
    value:"The remote HP-UX host is missing a security-related patch."
  );
  script_set_attribute(
    attribute:"description", 
    value:
"s700_800 11.22 CDE Applications Periodic Patch : 

Potential security vulnerabilities in CDE libraries and programs."
  );
  # http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?objectID=c00957810
  script_set_attribute(
    attribute:"see_also",
    value:"http://www.nessus.org/u?a4a7aa26"
  );
  script_set_attribute(
    attribute:"solution", 
    value:"Install patch PHSS_28683 or subsequent."
  );
  script_set_attribute(attribute:"risk_factor", value:"High");

  script_set_attribute(attribute:"plugin_type", value:"local");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:hp:hp-ux");

  script_set_attribute(attribute:"vuln_publication_date", value:"2003/05/01");
  script_set_attribute(attribute:"patch_publication_date", value:"2003/05/01");
  script_set_attribute(attribute:"plugin_publication_date", value:"2005/03/18");
  script_set_attribute(attribute:"patch_modification_date", value:"2007/04/12");
  script_set_attribute(attribute:"generated_plugin", value:"current");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_copyright(english:"This script is Copyright (C) 2005-2021 and is owned by Tenable, Inc. or an Affiliate thereof.");
  script_family(english:"HP-UX Local Security Checks");

  script_dependencies("ssh_get_info.nasl");
  script_require_keys("Host/local_checks_enabled", "Host/HP-UX/version", "Host/HP-UX/swlist");

  exit(0);
}


include("audit.inc");
include("global_settings.inc");
include("hpux.inc");


if (!get_kb_item("Host/local_checks_enabled")) audit(AUDIT_LOCAL_CHECKS_NOT_ENABLED);
if (!get_kb_item("Host/HP-UX/version")) audit(AUDIT_OS_NOT, "HP-UX");
if (!get_kb_item("Host/HP-UX/swlist")) audit(AUDIT_PACKAGE_LIST_MISSING);

if (!hpux_check_ctx(ctx:"11.22"))
{
  exit(0, "The host is not affected since PHSS_28683 applies to a different OS release.");
}

patches = make_list("PHSS_28683", "PHSS_29741", "PHSS_30670");
foreach patch (patches)
{
  if (hpux_installed(app:patch))
  {
    exit(0, "The host is not affected because patch "+patch+" is installed.");
  }
}


flag = 0;
if (hpux_check_patch(app:"CDE.CDE-ENG-A-MAN", version:"B.11.22")) flag++;
if (hpux_check_patch(app:"CDE.CDE-RUN", version:"B.11.22")) flag++;


if (flag)
{
  if (report_verbosity > 0) security_hole(port:0, extra:hpux_report_get());
  else security_hole(0);
  exit(0);
}
else audit(AUDIT_HOST_NOT, "affected");

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation

11 Jan 2021 00:00Current
7.1High risk
Vulners AI Score7.1
14