The version of Dell EMC NetWorker installed on the remote Windows host is 19.5 or earlier. It is, therefore, affected by version disclosure vulnerabilities for ‘Apache Tomcat’ and ‘RabbitMQ’. A NetWorker server user with remote access to NetWorker clients can exploit this vulnerability to prepare target-specific attacks.
Note that Nessus has not tested for this issue but has instead relied only on the application’s self-reported version number.
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(174982);
script_version("1.3");
script_set_attribute(attribute:"plugin_modification_date", value:"2023/09/28");
script_cve_id("CVE-2023-24567", "CVE-2023-25544");
script_xref(name:"IAVA", value:"2023-A-0271-S");
script_name(english:"Dell EMC NetWorker Version Disclosure (DSA-2023-058)");
script_set_attribute(attribute:"synopsis", value:
"The remote Windows host has an application installed that is affected by version disclosure vulnerabilities.");
script_set_attribute(attribute:"description", value:
"The version of Dell EMC NetWorker installed on the remote Windows host is 19.5 or earlier. It is, therefore, affected
by version disclosure vulnerabilities for 'Apache Tomcat' and 'RabbitMQ'. A NetWorker server user with remote access to
NetWorker clients can exploit this vulnerability to prepare target-specific attacks.
Note that Nessus has not tested for this issue but has instead relied only on the application's self-reported version
number.");
# https://www.dell.com/support/kbdoc/en-ie/000210471/dsa-2023-058-dell-networker-security-update-for-version-disclosure-vulnerability
script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?66246aa0");
script_set_attribute(attribute:"solution", value:
"Upgrade to Dell EMC NetWorker 19.6 or later.");
script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:S/C:C/I:N/A:N");
script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N");
script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2023-25544");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_set_attribute(attribute:"vuln_publication_date", value:"2023/03/01");
script_set_attribute(attribute:"patch_publication_date", value:"2023/03/01");
script_set_attribute(attribute:"plugin_publication_date", value:"2023/05/02");
script_set_attribute(attribute:"plugin_type", value:"local");
script_set_attribute(attribute:"cpe", value:"cpe:/a:dell:emc_networker");
script_set_attribute(attribute:"stig_severity", value:"I");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Windows");
script_copyright(english:"This script is Copyright (C) 2023 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("emc_networker_installed.nasl");
script_require_keys("installed_sw/EMC NetWorker", "SMB/Registry/Enumerated");
script_require_ports(139, 445);
exit(0);
}
include('vcf.inc');
get_kb_item_or_exit('SMB/Registry/Enumerated');
var app_info = vcf::get_app_info(app:'EMC NetWorker', win_local:TRUE);
# CVEs only affect server components so audit if the server is not installed.
if (!app_info['Server'])
vcf::audit(app_info);
var constraints = [
{ 'min_version' : '0.0', 'fixed_version' : '19.6' }
];
vcf::check_version_and_report(
app_info:app_info,
constraints:constraints,
severity:SECURITY_WARNING
);
Vendor | Product | Version | CPE |
---|---|---|---|
dell | emc_networker | cpe:/a:dell:emc_networker |