| Reporter | Title | Published | Views | Family All 12 |
|---|---|---|---|---|
| The vulnerability of the BIOS microprogramming software in Dell PowerEdge servers allows a hacker to disclose protected information. | 22 Sep 202500:00 | – | bdu_fstec | |
| Dell PowerEdge Platform 14G AMD BIOS 安全漏洞 | 14 Aug 202500:00 | – | cnnvd | |
| Dell PowerEdge Platform 14G AMD BIOS Information Disclosure Vulnerability | 20 Aug 202500:00 | – | cnvd | |
| CVE-2025-36581 | 14 Aug 202514:00 | – | cve | |
| CVE-2025-36581 | 14 Aug 202514:00 | – | cvelist | |
| Dell Client BIOS Information Disclosure (DSA-2025-299) | 22 Aug 202500:00 | – | nessus | |
| EUVD-2025-24839 | 3 Oct 202520:07 | – | euvd | |
| CVE-2025-36581 | 14 Aug 202514:15 | – | nvd | |
| CVE-2025-36581 | 14 Aug 202514:15 | – | osv | |
| PT-2025-33280 · Dell +1 · Dell Poweredge Platform +1 | 14 Aug 202500:00 | – | ptsecurity |
| Source | Link |
|---|---|
| nessus | www.nessus.org/u |
| cve | www.cve.mitre.org/cgi-bin/cvename.cgi |
#%NASL_MIN_LEVEL 80900
##
# (C) Tenable, Inc.
##
include('compat.inc');
if (description)
{
script_id(253651);
script_version("1.1");
script_set_attribute(attribute:"plugin_modification_date", value:"2025/08/22");
script_cve_id("CVE-2025-36581");
script_xref(name:"IAVA", value:"2025-A-0609");
script_name(english:"Dell Client BIOS Information Disclosure (WMI) (DSA-2025-299)");
script_set_attribute(attribute:"synopsis", value:
"The remote device is missing a vendor-supplied security patch");
script_set_attribute(attribute:"description", value:
"The Dell BIOS on the remote device is missing a security patch and is, therefore, affected by a vulnerability. Dell
PowerEdge Platform version(s) 14G AMD BIOS v1.25.0 and prior, contain(s) an Access of Memory Location After End of
Buffer vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading
to Information exposure.
Note that Nessus has not tested for this issue but has instead relied only on the application's self-reported version
number.");
# https://www.dell.com/support/kbdoc/en-us/000356405/dsa-2025-299-security-update-for-dell-poweredge-server-bios-for-an-access-of-memory-location-after-end-of-buffer-vulnerability
script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?c53e1456");
script_set_attribute(attribute:"solution", value:
"Update to version 1.26.0 or later");
script_set_cvss_base_vector("CVSS2#AV:L/AC:L/Au:S/C:P/I:N/A:N");
script_set_cvss3_base_vector("CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2025-36581");
script_set_attribute(attribute:"vuln_publication_date", value:"2025/08/14");
script_set_attribute(attribute:"patch_publication_date", value:"2025/08/14");
script_set_attribute(attribute:"plugin_publication_date", value:"2025/08/22");
script_set_attribute(attribute:"plugin_type", value:"local");
script_set_attribute(attribute:"cpe", value:"cpe:/o:dell:bios");
script_set_attribute(attribute:"stig_severity", value:"III");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Windows");
script_copyright(english:"This script is Copyright (C) 2025 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("bios_get_info_wmi.nbin");
script_require_keys("BIOS/Model", "BIOS/Version", "BIOS/Vendor");
exit(0);
}
include('vcf_extras.inc');
var app_name = 'Dell Inc.';
var app_info = vcf::dell_bios_win::get_app_info(app:app_name);
var model = app_info['model'];
var fix = '1.26.0';
if (empty_or_null(model))
{
exit(0, 'The model of the device running the Dell BIOS could not be identified.');
}
if (model != 'PowerEdge R6415' && model != 'PowerEdge R7415' && model != 'PowerEdge R7425')
{
audit(AUDIT_HOST_NOT, 'an affected model');
}
var constraints = [{ 'fixed_version' : fix, 'fixed_display': fix + ' for ' + model }];
# Have a more useful audit message
app_info.app = 'Dell System BIOS for ' + model;
vcf::check_version_and_report(app_info:app_info, constraints:constraints, severity:SECURITY_NOTE);
Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation