Lucene search
+L

CitectSCADA Detection

CitectSCADA detection from file citectscada_detect.nas

Refs
Code
SourceLink
nessuswww.nessus.org/u
#
#  (C) Tenable Network Security, Inc.
#

include("compat.inc");

if (description)
{
  script_id(33169);
  script_version("1.16");
  script_set_attribute(attribute:"plugin_modification_date", value:"2023/05/24");

  script_name(english:"CitectSCADA Detection");
  script_summary(english:"Gets version of CitectSCADA");

  script_set_attribute(attribute:"synopsis", value:"The remote Windows host is running CitectSCADA.");
  script_set_attribute(attribute:"description", value:
"The remote host is running CitectSCADA, which is used to gather data
from PLC's, RTU's and present it within an Human Machine Interface
(HMI) for control and monitoring of physical processes. CitectSCADA is
commonly found in power, electric, water, and other SCADA systems.");
  #http://www.citect.com/index.php?option=com_content&view=article&id=1457&Itemid=1314
  script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?e3106c49" );
  script_set_attribute(attribute:"risk_factor", value:"None");
  script_set_attribute(attribute:"solution", value:"n/a");
  script_set_attribute(attribute:"agent", value:"windows");

  script_set_attribute(attribute:"plugin_publication_date", value:"2008/06/13");

  script_set_attribute(attribute:"plugin_type", value:"local");
  script_set_attribute(attribute:"cpe", value:"cpe:/a:citect:citectscada");
  script_set_attribute(attribute:"asset_inventory", value:"True");
  script_set_attribute(attribute:"asset_inventory_category", value:"software_enumeration");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"SCADA");

  script_copyright(english:"This script is Copyright (C) 2008-2023 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("smb_hotfixes.nasl");
  script_require_keys("SMB/Registry/Enumerated");
  script_require_ports(139, 445);

  exit(0);
}


include("global_settings.inc");
include("smb_func.inc");
include("audit.inc");
include("misc_func.inc");
include("install_func.inc");

app = "CitectSCADA";

if (!get_kb_item("SMB/Registry/Enumerated")) exit(0);


# Connect to the appropriate share.
name    =  kb_smb_name();
port    =  kb_smb_transport();

login   =  kb_smb_login();
pass    =  kb_smb_password();
domain  =  kb_smb_domain();



if(! smb_session_init()) audit(AUDIT_FN_FAIL, 'smb_session_init');
rc = NetUseAdd(login:login, password:pass, domain:domain, share:"IPC$");
if (rc != 1) {
  NetUseDel();
  exit(0);
}


# Connect to remote registry.
hklm = RegConnectRegistry(hkey:HKEY_LOCAL_MACHINE);
if (isnull(hklm))
{
  NetUseDel();
  exit(0);
}


# Find where it's installed.
path = NULL;

key = "SOFTWARE\Citect\Citect HMI/SCADA";
key_h = RegOpenKey(handle:hklm, key:key, mode:MAXIMUM_ALLOWED);
if (!isnull(key_h))
{
  info = RegQueryInfoKey(handle:key_h);
  for (i=0; i<info[1]; ++i)
  {
    subkey = RegEnumKey(handle:key_h, index:i);
    if (strlen(subkey) && subkey =~ "^[0-9]+\.")
    {
      key2 = key + "\" + subkey;
      key2_h = RegOpenKey(handle:hklm, key:key2, mode:MAXIMUM_ALLOWED);
      if (!isnull(key2_h))
      {
        item = RegQueryValue(handle:key2_h, item:"InstallDir");
        if (!isnull(item))
        {
          path = item[1];
          path = ereg_replace(pattern:"^(.+)\\$", replace:"\1", string:path);
        }
        RegCloseKey(handle:key2_h);
      }
    }
  }
  RegCloseKey (handle:key_h);
}
RegCloseKey(handle:hklm);
if (isnull(path))
{
  NetUseDel();
  exit(0);
}
NetUseDel(close:FALSE);


# Determine its version.
share = ereg_replace(pattern:"^([A-Za-z]):.*", replace:"\1$", string:path);
xml   = ereg_replace(pattern:"^[A-Za-z]:(.*)", replace:"\1\bin\CtVersion.xml", string:path);

rc = NetUseAdd(login:login, password:pass, domain:domain, share:share);
if (rc != 1)
{
  NetUseDel();
  exit(0);
}

fh = CreateFile(
  file:xml,
  desired_access:GENERIC_READ,
  file_attributes:FILE_ATTRIBUTE_NORMAL,
  share_mode:FILE_SHARE_READ,
  create_disposition:OPEN_EXISTING
);
version = NULL;
if (!isnull(fh))
{
  fsize = GetFileSize(handle:fh);
  data = ReadFile(handle:fh, length:fsize, offset:0);
  if ("<BUILD" >< data)
  {
    build = strstr(data, "<BUILD") - "<BUILD";
    build = build - strstr(build, "</BUILD>");

    if ("<LABEL>" >< build)
    {
      version = strstr(data, "<LABEL>") - "<LABEL>";
      version = version - strstr(version, "<");
      if (version !~ "^[0-9][0-9.]+") version = NULL;
    }
  }

  CloseFile(handle:fh);
}
NetUseDel();


if (version)
{
  kb_key = "SCADA/CitectSCADA";
  set_kb_item(name:kb_key, value:TRUE);
  set_kb_item(name:kb_key+"/Version", value:version);
  set_kb_item(name:kb_key+"/Path", value:path);

  register_install(
    vendor:"Citect",
    product:"CitectSCADA",
    app_name:app,
    path:path,
    version:version,
    cpe: "cpe:/a:citect:citectscada");

  report_installs(app_name:app, port:port);
}

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation

24 May 2023 00:00Current
6.6Medium risk
Vulners AI Score6.6
21