Lucene search

K
nessusThis script is Copyright (C) 2020 and is owned by Tenable, Inc. or an Affiliate thereof.CISCO-SA-FMCXSS-UT3BMX9K.NASL
HistoryMay 15, 2020 - 12:00 a.m.

Cisco Firepower Management Center XSS (cisco-sa-fmcxss-UT3bMx9k)

2020-05-1500:00:00
This script is Copyright (C) 2020 and is owned by Tenable, Inc. or an Affiliate thereof.
www.tenable.com
8

4.3 Medium

CVSS2

Attack Vector

NETWORK

Attack Complexity

MEDIUM

Authentication

NONE

Confidentiality Impact

NONE

Integrity Impact

PARTIAL

Availability Impact

NONE

AV:N/AC:M/Au:N/C:N/I:P/A:N

6.1 Medium

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

REQUIRED

Scope

CHANGED

Confidentiality Impact

LOW

Integrity Impact

LOW

Availability Impact

NONE

CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N

0.002 Low

EPSS

Percentile

51.5%

According to its self-reported version, Cisco Firepower Management Center is affected by a cross-site scripting (XSS) vulnerability. The vulnerability exists in the web-based management interface of FMC software due to improper validation of user-supplied input before returning it to users. An unauthenticated, remote attacker can exploit this, by convincing a user to click a specially crafted URL, to execute arbitrary script code in a user’s browser session.

#
# (C) Tenable Network Security, Inc.
#

include('compat.inc');

if (description)
{
  script_id(136612);
  script_version("1.3");
  script_set_attribute(attribute:"plugin_modification_date", value:"2020/10/09");

  script_cve_id("CVE-2020-3313");
  script_xref(name:"CISCO-BUG-ID", value:"CSCvh20060");
  script_xref(name:"CISCO-SA", value:"cisco-sa-fmcxss-UT3bMx9k");
  script_xref(name:"IAVA", value:"2020-A-0206-S");

  script_name(english:"Cisco Firepower Management Center XSS (cisco-sa-fmcxss-UT3bMx9k)");

  script_set_attribute(attribute:"synopsis", value:
"The remote device is missing a vendor-supplied security patch.");
  script_set_attribute(attribute:"description", value:
"According to its self-reported version, Cisco Firepower Management Center is affected by a cross-site scripting (XSS)
vulnerability. The vulnerability exists in the web-based management interface of FMC software due to improper validation
of user-supplied input before returning it to users. An unauthenticated, remote attacker can exploit this, by convincing
a user to click a specially crafted URL, to execute arbitrary script code in a user's browser session.");
  # https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmcxss-UT3bMx9k
  script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?498c8df8");
  script_set_attribute(attribute:"see_also", value:"https://bst.cloudapps.cisco.com/bugsearch/bug/CSCvh20060");
  script_set_attribute(attribute:"solution", value:
"Upgrade to the relevant fixed version referenced in Cisco bug ID CSCvh20060");
  script_set_cvss_base_vector("CVSS2#AV:N/AC:M/Au:N/C:N/I:P/A:N");
  script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
  script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N");
  script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
  script_set_attribute(attribute:"cvss_score_source", value:"CVE-2020-3313");

  script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
  script_cwe_id(79);

  script_set_attribute(attribute:"vuln_publication_date", value:"2020/05/06");
  script_set_attribute(attribute:"patch_publication_date", value:"2020/05/06");
  script_set_attribute(attribute:"plugin_publication_date", value:"2020/05/15");

  script_set_attribute(attribute:"plugin_type", value:"local");
  script_set_attribute(attribute:"cpe", value:"cpe:/o:cisco:firepower_management_center");
  script_set_attribute(attribute:"stig_severity", value:"I");
  script_end_attributes();

  script_category(ACT_GATHER_INFO);
  script_family(english:"CISCO");

  script_copyright(english:"This script is Copyright (C) 2020 and is owned by Tenable, Inc. or an Affiliate thereof.");

  script_dependencies("cisco_firepower_version.nasl");
  script_require_keys("Host/Cisco/firepower_mc/version");

  exit(0);
}

include('vcf.inc');

app = 'Cisco Firepower Management Center';
app_info = vcf::get_app_info(app:app, kb_ver:'Host/Cisco/firepower_mc/version');

vcf::check_granularity(app_info:app_info, sig_segments:3);

constraints = [
  { 'fixed_version' : '6.2.2.3' }
];

vcf::check_version_and_report(app_info:app_info, constraints:constraints, severity:SECURITY_WARNING, flags:{'xss': TRUE});
VendorProductVersionCPE
ciscofirepower_management_centercpe:/o:cisco:firepower_management_center

4.3 Medium

CVSS2

Attack Vector

NETWORK

Attack Complexity

MEDIUM

Authentication

NONE

Confidentiality Impact

NONE

Integrity Impact

PARTIAL

Availability Impact

NONE

AV:N/AC:M/Au:N/C:N/I:P/A:N

6.1 Medium

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

REQUIRED

Scope

CHANGED

Confidentiality Impact

LOW

Integrity Impact

LOW

Availability Impact

NONE

CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N

0.002 Low

EPSS

Percentile

51.5%

Related for CISCO-SA-FMCXSS-UT3BMX9K.NASL