3.5 Low
CVSS2
Attack Vector
NETWORK
Attack Complexity
MEDIUM
Authentication
SINGLE
Confidentiality Impact
NONE
Integrity Impact
PARTIAL
Availability Impact
NONE
AV:N/AC:M/Au:S/C:N/I:P/A:N
4.8 Medium
CVSS3
Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
HIGH
User Interaction
REQUIRED
Scope
CHANGED
Confidentiality Impact
LOW
Integrity Impact
LOW
Availability Impact
NONE
CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
5.4 Medium
AI Score
Confidence
High
0.001 Low
EPSS
Percentile
29.3%
According to its self-reported version, Cisco Firepower Management Center is affected by multiple cross-site scripting (XSS) vulnerabilities due to improper validation of user-supplied input before returning it to users. An unauthenticated, remote attacker can exploit this, by convincing a user to click a specially crafted URL, to execute arbitrary script code in a user’s browser session.
Please see the included Cisco BIDs and Cisco Security Advisory for more information
#
# (C) Tenable Network Security, Inc.
#
include('compat.inc');
if (description)
{
script_id(130211);
script_version("1.4");
script_set_attribute(attribute:"plugin_modification_date", value:"2024/04/17");
script_cve_id("CVE-2019-15268", "CVE-2019-15269");
script_xref(name:"CISCO-BUG-ID", value:"CSCvq53902");
script_xref(name:"CISCO-BUG-ID", value:"CSCvq53915");
script_xref(name:"CISCO-SA", value:"cisco-sa-20191016-firepwr-xss");
script_name(english:"Cisco Firepower Management Center Multiple Cross-Site Scripting Vulnerabilities (cisco-sa-20191016-firepwr-xss)");
script_set_attribute(attribute:"synopsis", value:
"The remote device is missing a vendor-supplied security patch");
script_set_attribute(attribute:"description", value:
"According to its self-reported version, Cisco Firepower
Management Center is affected by multiple cross-site scripting (XSS) vulnerabilities due to improper validation of
user-supplied input before returning it to users. An unauthenticated, remote attacker can exploit this, by convincing
a user to click a specially crafted URL, to execute arbitrary script code in a user's browser session.
Please see the included Cisco BIDs and Cisco Security Advisory for more information");
# http://tools.cisco.com/security/center/content/CiscoAppliedMitigationBulletin/cisco-amb-20060922-understanding-xss
script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?1596bcb6");
# https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191016-firepwr-xss
script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?c082a447");
script_set_attribute(attribute:"see_also", value:"https://bst.cloudapps.cisco.com/bugsearch/bug/CSCvq53902");
script_set_attribute(attribute:"see_also", value:"https://bst.cloudapps.cisco.com/bugsearch/bug/CSCvq53915");
script_set_attribute(attribute:"solution", value:
"Upgrade to the relevant fixed version referenced in Cisco bug IDs
CSCvq53902, CSCvq53915");
script_set_cvss_base_vector("CVSS2#AV:N/AC:M/Au:S/C:N/I:P/A:N");
script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N");
script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2019-15269");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_set_attribute(attribute:"exploit_available", value:"false");
script_cwe_id(79);
script_set_attribute(attribute:"vuln_publication_date", value:"2019/10/16");
script_set_attribute(attribute:"patch_publication_date", value:"2019/10/16");
script_set_attribute(attribute:"plugin_publication_date", value:"2019/10/25");
script_set_attribute(attribute:"plugin_type", value:"local");
script_set_attribute(attribute:"cpe", value:"cpe:/o:cisco:firepower_management_center");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"CISCO");
script_copyright(english:"This script is Copyright (C) 2019-2024 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("cisco_firepower_version.nasl");
script_require_keys("Host/Cisco/firepower_mc/version");
exit(0);
}
include('vcf.inc');
app_info = vcf::get_app_info(app:'Cisco Firepower Management Center', kb_ver:'Host/Cisco/firepower_mc/version');
constraints = [{'fixed_version': '6.5.0'}];
vcf::check_version_and_report(
app_info:app_info,
constraints:constraints,
severity:SECURITY_NOTE,
flags:{'xss':TRUE}
);
Vendor | Product | Version | CPE |
---|---|---|---|
cisco | firepower_management_center | cpe:/o:cisco:firepower_management_center |
3.5 Low
CVSS2
Attack Vector
NETWORK
Attack Complexity
MEDIUM
Authentication
SINGLE
Confidentiality Impact
NONE
Integrity Impact
PARTIAL
Availability Impact
NONE
AV:N/AC:M/Au:S/C:N/I:P/A:N
4.8 Medium
CVSS3
Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
HIGH
User Interaction
REQUIRED
Scope
CHANGED
Confidentiality Impact
LOW
Integrity Impact
LOW
Availability Impact
NONE
CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
5.4 Medium
AI Score
Confidence
High
0.001 Low
EPSS
Percentile
29.3%