6.8 Medium
CVSS2
Attack Vector
NETWORK
Attack Complexity
MEDIUM
Authentication
NONE
Confidentiality Impact
PARTIAL
Integrity Impact
PARTIAL
Availability Impact
PARTIAL
AV:N/AC:M/Au:N/C:P/I:P/A:P
0.082 Low
EPSS
Percentile
94.4%
The remote host contains the AdView.AdViewer ActiveX control, distributed with Autodesk Design Review, that is affected by a remote code execution vulnerability due to improper parsing of DWF files. An unauthenticated, remote attacker can exploit this, via a specially crafted file or website, to execute arbitrary code.
#
# (C) Tenable Network Security, Inc.
#
include("compat.inc");
if (description)
{
script_id(81318);
script_version("1.8");
script_cvs_date("Date: 2019/11/25");
script_cve_id("CVE-2014-9268");
script_bugtraq_id(71485);
script_xref(name:"ZDI", value:"ZDI-14-402");
script_name(english:"Autodesk Design Review AdView.AdViewer ActiveX Control RCE");
script_summary(english:"Checks the version of the ActiveX control.");
script_set_attribute(attribute:"synopsis", value:
"The remote Windows host has an ActiveX control that is affected by a
remote code execution vulnerability.");
script_set_attribute(attribute:"description", value:
"The remote host contains the AdView.AdViewer ActiveX control,
distributed with Autodesk Design Review, that is affected by a remote
code execution vulnerability due to improper parsing of DWF files. An
unauthenticated, remote attacker can exploit this, via a specially
crafted file or website, to execute arbitrary code.");
script_set_attribute(attribute:"see_also", value:"https://www.zerodayinitiative.com/advisories/ZDI-14-402/");
# https://knowledge.autodesk.com/support/design-review/downloads/caas/downloads/content/autodesk-design-review-2013-hotfix.html
script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?737f5f11");
script_set_attribute(attribute:"solution", value:
"Apply the 2013 hotfix.
Note that older versions will need to be updated to 2013 before
applying the hotfix.");
script_set_cvss_base_vector("CVSS2#AV:N/AC:M/Au:N/C:P/I:P/A:P");
script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
script_set_cvss3_base_vector("CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H");
script_set_cvss3_temporal_vector("CVSS:3.0/E:U/RL:O/RC:C");
script_set_attribute(attribute:"cvss_score_source", value:"CVE-2014-9268");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_set_attribute(attribute:"exploit_available", value:"false");
script_set_attribute(attribute:"vuln_publication_date", value:"2014/07/11");
script_set_attribute(attribute:"patch_publication_date", value:"2014/07/06");
script_set_attribute(attribute:"plugin_publication_date", value:"2015/02/12");
script_set_attribute(attribute:"plugin_type", value:"local");
script_set_attribute(attribute:"cpe", value:"cpe:/a:autodesk:design_review_2008");
script_set_attribute(attribute:"cpe", value:"cpe:/a:autodesk:design_review_2009");
script_set_attribute(attribute:"cpe", value:"cpe:/a:autodesk:design_review_2010");
script_set_attribute(attribute:"cpe", value:"cpe:/a:autodesk:design_review_2011");
script_set_attribute(attribute:"cpe", value:"cpe:/a:autodesk:design_review_2012");
script_set_attribute(attribute:"cpe", value:"cpe:/a:autodesk:design_review:2013");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"Windows");
script_copyright(english:"This script is Copyright (C) 2015-2019 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("smb_hotfixes.nasl", "autodesk_dr_installed.nbin");
script_require_keys("installed_sw/Autodesk Design Review");
script_require_ports(139, 445);
exit(0);
}
include("audit.inc");
include("global_settings.inc");
include("install_func.inc");
include("misc_func.inc");
include("smb_func.inc");
include("smb_activex_func.inc");
app = "Autodesk Design Review";
get_install_count(app_name:app, exit_if_zero:TRUE);
# Locate the file used by the controls.
if (activex_init() != ACX_OK) exit(1, "Unable to initialize the ActiveX API.");
clsid = "{a662da7e-ccb7-4743-b71a-d817f6d575df}";
file = activex_get_filename(clsid:clsid);
if (isnull(file))
{
activex_end();
audit(AUDIT_FN_FAIL, 'activex_get_filename');
}
if (!file)
{
activex_end();
audit(AUDIT_ACTIVEX_NOT_FOUND, clsid);
}
ver = activex_get_fileversion(clsid:clsid);
if (isnull(ver))
{
activex_end();
audit(AUDIT_VER_FAIL, file);
}
activex_end();
fixed = '13.1.0.82';
if (ver_compare(ver:ver, fix:fixed, strict:FALSE) == -1)
{
port = kb_smb_transport();
report = NULL;
if (report_verbosity > 0)
{
report =
'\n Class identifier : ' + clsid +
'\n Filename : ' + file +
'\n Installed version : ' + ver +
'\n Fixed version : ' + fixed +
'\n';
security_warning(port:port, extra:report);
}
else security_warning(port);
}
else audit(AUDIT_INST_VER_NOT_VULN, file, ver);
Vendor | Product | Version | CPE |
---|---|---|---|
autodesk | design_review_2008 | cpe:/a:autodesk:design_review_2008 | |
autodesk | design_review_2009 | cpe:/a:autodesk:design_review_2009 | |
autodesk | design_review_2010 | cpe:/a:autodesk:design_review_2010 | |
autodesk | design_review_2011 | cpe:/a:autodesk:design_review_2011 | |
autodesk | design_review_2012 | cpe:/a:autodesk:design_review_2012 | |
autodesk | design_review | 2013 | cpe:/a:autodesk:design_review:2013 |