CVSS2
Attack Vector
NETWORK
Attack Complexity
LOW
Authentication
NONE
Confidentiality Impact
PARTIAL
Integrity Impact
NONE
Availability Impact
NONE
AV:N/AC:L/Au:N/C:P/I:N/A:N
EPSS
Percentile
74.9%
The version of ManageEngine Applications Manager installed on the remote host is affected by an information disclosure vulnerability due to the application returning a summary of monitor groups and alerts in response to a request with an invalid URL. A remote attacker, using a URL with an invalid target location, can exploit this to access sensitive ‘Home->Summary’ information about the applications and services being monitored.
Note that this version may also be affected by several other information disclosure and cross-site scripting vulnerabilities, however Nessus did not explicitly check for these issues.
#%NASL_MIN_LEVEL 70300
#
# (C) Tenable Network Security, Inc.
#
include('deprecated_nasl_level.inc');
include('compat.inc');
if (description)
{
script_id(30056);
script_version("1.19");
script_set_attribute(attribute:"plugin_modification_date", value:"2021/01/19");
script_cve_id("CVE-2008-0475");
script_bugtraq_id(27443);
script_name(english:"ManageEngine Applications Manager Invalid URL Remote Information Disclosure");
script_summary(english:"Sends an invalid URL to Applications Manager.");
script_set_attribute(attribute:"synopsis", value:
"The remote web server is running an application affected by an
information disclosure vulnerability.");
script_set_attribute(attribute:"description", value:
"The version of ManageEngine Applications Manager installed on the
remote host is affected by an information disclosure vulnerability due
to the application returning a summary of monitor groups and alerts in
response to a request with an invalid URL. A remote attacker, using a
URL with an invalid target location, can exploit this to access
sensitive 'Home->Summary' information about the applications and
services being monitored.
Note that this version may also be affected by several other
information disclosure and cross-site scripting vulnerabilities,
however Nessus did not explicitly check for these issues.");
# https://packetstormsecurity.com/files/62946/Secunia-Security-Advisory-28332.html
script_set_attribute(attribute:"see_also", value:"http://www.nessus.org/u?7c7eb7e6");
script_set_attribute(attribute:"solution", value:"Contact the vendor for a patch or upgrade details.");
script_set_cvss_base_vector("CVSS2#AV:N/AC:L/Au:N/C:P/I:N/A:N");
script_set_cvss_temporal_vector("CVSS2#E:U/RL:OF/RC:C");
script_set_attribute(attribute:"exploitability_ease", value:"No known exploits are available");
script_set_attribute(attribute:"exploit_available", value:"false");
script_cwe_id(20);
script_set_attribute(attribute:"vuln_publication_date", value:"2008/01/24");
script_set_attribute(attribute:"plugin_publication_date", value:"2008/01/26");
script_set_attribute(attribute:"plugin_type", value:"remote");
script_set_attribute(attribute:"cpe", value:"cpe:/a:manageengine:applications_manager");
script_end_attributes();
script_category(ACT_GATHER_INFO);
script_family(english:"CGI abuses");
script_copyright(english:"This script is Copyright (C) 2008-2021 and is owned by Tenable, Inc. or an Affiliate thereof.");
script_dependencies("manageengine_applications_manager_detect.nasl");
script_require_keys("installed_sw/ManageEngine Applications Manager");
script_require_ports("Services/www", 9090);
exit(0);
}
include("audit.inc");
include("global_settings.inc");
include("misc_func.inc");
include("http.inc");
include("install_func.inc");
app = "ManageEngine Applications Manager";
get_install_count(app_name:app, exit_if_zero:TRUE);
port = get_http_port(default:9090);
install = get_single_install(
app_name : app,
port : port
);
dir = install['path'];
install_url = build_url(port:port, qs:dir);
# Exploit the issue.
res = http_send_recv3(
method : "GET",
item : "/-",
port : port,
fetch404 : TRUE,
exit_on_fail : TRUE
);
# There's a problem if we get to AppManager's Monitor Groups display.
if (
"title>Applications Manager - Monitor Groups<" >< res[2] &&
"<!--$Id: Recent" >< res[2]
)
{
output = strstr(res[2], "title>Applications Manager");
if (empty_or_null(output)) output = res[2];
security_report_v4(
port : port,
severity : SECURITY_WARNING,
generic : TRUE,
request : make_list(install_url + "/-"),
output : chomp(output)
);
}
else audit(AUDIT_WEB_APP_NOT_AFFECTED, app, install_url);