icsIndustrial Control Systems Cyber Emergency Response TeamICSA-24-156-01
HistoryJun 04, 2024 - 12:00 p.m.

Uniview NVR301-04S2-P4

2024-06-0412:00:00
Industrial Control Systems Cyber Emergency Response Team
www.cisa.gov
uniview
nvr301-04s2-p4
cross-site scripting
cve-2024-3850
vulnerability
exploitable
javascript
network video recorder
mitigations
cisa

5.4 Medium

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

LOW

User Interaction

REQUIRED

Scope

CHANGED

Confidentiality Impact

LOW

Integrity Impact

LOW

Availability Impact

NONE

CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N

4.8 Medium

CVSS4

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

LOW

User Interaction

ACTIVE

CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:A/VC:L/SC:L/VI:L/SI:L/VA:N/SA:N

6.9 Medium

AI Score

Confidence

High

0.0004 Low

EPSS

Percentile

14.1%

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 4.8 *ATTENTION: Exploitable remotely/low attack complexity/public exploits available
  • Vendor: Uniview
  • Equipment: NVR301-04S2-P4
  • Vulnerability: Cross-site Scripting

2. RISK EVALUATION

An attacker could send a user a URL that if clicked on could execute malicious JavaScript in their browser.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following version of Uniview NVR, a network video recorder, is affected:

  • NVR301-04S2-P4: Versions prior to NVR-B3801.20.17.240507

3.2 Vulnerability Overview

3.2.1Improper Neutralization of Input During Web Page Generation (‘Cross-site Scripting’) CWE-79

The affected product is vulnerable to reflected cross-site scripting attack (XSS). An attacker could send a user a URL that if clicked on could execute malicious JavaScript in their browser. This vulnerability also requires authentication before it can be exploited, so the scope and severity is limited. Also, even if JavaScript is executed, no additional benefits are obtained.

CVE-2024-3850 has been assigned to this vulnerability. A CVSS v3.1 base score of 5.4 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N).

A CVSS v4 score has also been calculated for CVE-2024-3850. A base score of 4.8 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:A/VC:L/VI:L/VA:N/SC:L/SI:L/SA:N).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Commercial Facilities
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: China

3.4 RESEARCHER

CISA discovered a public Proof of Concept (PoC) as authored by Bleron Rrustemi and reported it to Uniview.

4. MITIGATIONS

Uniview encourages users to obtain the fixed version, Uniview NVR-B3801.20.17.240507, and update. You may contact your local dealer, Uniview Service Hotline, or regional technical support for assistance.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the Internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.
    CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

5. UPDATE HISTORY

  • June 4, 2024: Initial Publication

References

5.4 Medium

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

LOW

User Interaction

REQUIRED

Scope

CHANGED

Confidentiality Impact

LOW

Integrity Impact

LOW

Availability Impact

NONE

CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N

4.8 Medium

CVSS4

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

LOW

User Interaction

ACTIVE

CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:A/VC:L/SC:L/VI:L/SI:L/VA:N/SA:N

6.9 Medium

AI Score

Confidence

High

0.0004 Low

EPSS

Percentile

14.1%

Related for ICSA-24-156-01