Lucene search

K
icsIndustrial Control Systems Cyber Emergency Response TeamICSA-23-285-13
HistoryOct 12, 2023 - 12:00 p.m.

Mitsubishi Electric MELSEC-F Series

2023-10-1212:00:00
Industrial Control Systems Cyber Emergency Response Team
www.cisa.gov
11
melsec-f series
improper authentication
remote exploitation
mitsubishi electric
vulnerability
cvss v3 9.1
ethernet communication
firewall
lan security
cisa advisory
critical manufacturing
japan
cwe-287
cve-2023-4562

9.1 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

NONE

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N

0.001 Low

EPSS

Percentile

44.5%

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v3 9.1 *ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Mitsubishi Electric Corporation
  • Equipment: MELSEC-F Series
  • Vulnerability: Improper Authentication

2. RISK EVALUATION

Successful exploitation of this vulnerability may allow a remote attacker to obtain sequence programs from the product, write malicious sequence programs, or improper data in the product without authentication.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

Mitsubishi Electric reports that the following versions of MELSEC-F series programmable controllers are affected if they are used with ethernet communication special adapter FX3U-ENET-ADP or ethernet communication block FX3U-ENET(-L) with the exception of "FX3GE-xMy/z x=24,40, y=T, R, z=ES, ESS, DS, DSS. Some of these products are sold in limited regions, see the Mitsubishi Electric advisory for details:

  • MELSEC-F series FX3U-xMy/z x=16,32,48,64,80,128, y=T,R, z=ES,ESS,DS,DSS: All versions.
  • MELSEC-F series FX3U-32MR/UA1, FX3U-64MR/UA1: All versions.
  • MELSEC-F FX3U-32MS/ES, FX3U-64MS/ES: All versions.
  • MELSEC-F FX3U-xMy/ES-A x=16,32,48,64,80,128, y=T,R: All versions.
  • MELSEC-F FX3UC-xMT/z x=16,32,64,96, z=D,DSS: All versions.
  • MELSEC-F FX3UC-16MR/D-T, FX3UC-16MR/DS-T: All versions.
  • MELSEC-F FX3UC-32MT-LT, FX3UC-32MT-LT-2: All versions.
  • MELSEC-F FX3UC-16MT/D-P4, FX3UC-16MT/DSS-P4: All versions.
  • MELSEC-F FX3G-xMy/z x=14,24,40,60, y=T,R, z=ES,ESS,DS,DSS: All versions.
  • MELSEC-F FX3G-xMy/ES-A x=14,24,40,60, y=T,R: All versions.
  • MELSEC-F FX3GC-32MT/D, FX3GC-32MT/DSS: All versions.
  • MELSEC-F FX3GE-xMy/z x=24,40, y=T,R, z=ES,ESS,DS,DSS: All versions.
  • MELSEC-F FX3GA-xMy-CM x=24,40,60, y=T,R: All versions.
  • MELSEC-F FX3S-xMy/z x=10,14,20,30, y=T,R, z=ES,ESS,DS,DSS: All versions.
  • MELSEC-F FX3S-30My/z-2AD y=T,R, z=ES,ESS: All versions.
  • MELSEC-F FX3SA-xMy-CM x=10,14,20,30, y=T,R: All versions.

3.2 Vulnerability Overview

3.2.1 Improper Authentication CWE-287

Information disclosure, information tampering and authentication bypass vulnerability due to improper authentication exists in the MELSEC-F Series main modules.

CVE-2023-4562 has been assigned to this vulnerability. A CVSS v3 base score of 9.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Japan

3.4 RESEARCHER

Mitsubishi Electric reported this vulnerability to CISA.

4. MITIGATIONS

Mitsubishi Electric recommends that customers take the following mitigation measures to minimize the risk of exploiting this vulnerability:

  • Use a firewall or virtual private network (VPN), etc. to prevent unauthorized access when Internet access is required.
  • Use within a LAN and block access from untrusted networks and hosts through firewalls.
  • Restrict physical access to the affected products and the LAN that is connected by them.

For specific update instructions and additional details see the Mitsubishi Electric advisory.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.

5. UPDATE HISTORY

  • October 12, 2023: Initial Publication

References

9.1 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

NONE

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N

0.001 Low

EPSS

Percentile

44.5%

Related for ICSA-23-285-13