Lucene search

K
icsIndustrial Control Systems Cyber Emergency Response TeamICSA-23-131-15
HistoryMay 11, 2023 - 12:00 p.m.

Rockwell Automation ThinManager

2023-05-1112:00:00
Industrial Control Systems Cyber Emergency Response Team
www.cisa.gov
17
rockwell automation
thinmanager
vulnerability
encryption strength
upgrade
security best practices
cve-2023-2443
cvss v3 7.5
cisa
network exposure
firewalls
vpns
impact analysis
risk assessment
control systems security

CVSS3

7.5

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

NONE

Availability Impact

NONE

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

EPSS

0.001

Percentile

35.1%

1. EXECUTIVE SUMMARY

  • CVSS v3 7.5 *ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Rockwell Automation
  • Equipment: ThinManager
  • Vulnerabilities: Inadequate Encryption Strength

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an attacker to decrypt traffic sent between the client and server application programming interface (API), resulting in unauthorized access to information.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of ThinManager, a software management platform, are affected:

  • ThinManager: Versions 13.0 to 13.0.1

3.2 VULNERABILITY OVERVIEW

3.2.1 INADEQUATE ENCRYPTION STRENGTH CWE-326

The affected product allows the use of medium-strength ciphers. If the client requests an insecure cipher, then a malicious actor could decrypt traffic sent between the client and server API.

CVE-2023-2443 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).

3.3 BACKGROUND

  • **CRITICAL INFRASTRUCTURE SECTORS:**Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • **COMPANY HEADQUARTERS LOCATION:**United States

3.4 RESEARCHER

Rockwell Automation reported this vulnerability to CISA.

4. MITIGATIONS

Users of the affected software are encouraged to apply risk mitigations when possible and implement Rockwell Automationโ€™s suggested security best practices to minimize risk of vulnerability exploitation.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:

  • Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolate them from business networks.
  • When remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices at cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

Additional mitigation guidance and recommended practices are publicly available at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01Bโ€“Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploits specifically target this vulnerability.

References

CVSS3

7.5

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

NONE

Availability Impact

NONE

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

EPSS

0.001

Percentile

35.1%

Related for ICSA-23-131-15