icsIndustrial Control Systems Cyber Emergency Response TeamICSA-21-259-02
HistorySep 20, 2021 - 12:00 p.m.

Schneider Electric EcoStruxure and SCADAPack

2021-09-2012:00:00
Industrial Control Systems Cyber Emergency Response Team
www.cisa.gov
20
schneider electric
path traversal
code execution
mitigations
vulnerability
control system
remote access
vpn
cwe-22
cve-2021-22797

CVSS2

9.3

Attack Vector

NETWORK

Attack Complexity

MEDIUM

Authentication

NONE

Confidentiality Impact

COMPLETE

Integrity Impact

COMPLETE

Availability Impact

COMPLETE

AV:N/AC:M/Au:N/C:C/I:C/A:C

CVSS3

7.8

Attack Vector

LOCAL

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

REQUIRED

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

AI Score

8

Confidence

High

EPSS

0.002

Percentile

58.9%

1. EXECUTIVE SUMMARY

  • CVSS v3 7.8 ***ATTENTION: **Low attack complexity
  • Vendor: Schneider Electric
  • **Equipment:**EcoStruxure Control Expert, EcoStruxure Process Expert, SCADAPack RemoteConnect for x70
  • **Vulnerability:**Path Traversal

2. RISK EVALUATION

Successful exploitation of this vulnerability could result in code execution on the engineering workstation.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following products and versions are affected:

  • EcoStruxure Control Expert: All versions, including former Unity Pro
  • EcoStruxure Process Expert: All versions, including former HDCS
  • SCADAPack RemoteConnect for x70: All versions

3.2 VULNERABILITY OVERVIEW

3.2.1 IMPROPER LIMITATION OF A PATHNAME TO A RESTRICTED DIRECTORY (β€˜PATH TRAVERSAL’) CWE-22

When a malicious project file is loaded on the engineering workstation software, it deploys a malicious script to execute arbitrary code in unauthorized locations.

CVE-2021-22797 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.3 BACKGROUND

  • **CRITICAL INFRASTRUCTURE SECTORS:**Commercial Facilities, Energy, Food and Agriculture, Government Facilities, Transportation Systems, Water and Wastewater Systems
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • **COMPANY HEADQUARTERS LOCATION:**France

3.4 RESEARCHER

kimiya, working with Trend Micro Zero’s Day Initiative, reported this vulnerability to CISA.

4. MITIGATIONS

Schneider Electric is establishing a remediation plan for future versions of the affected products that will include a fix for this vulnerability. CISA will update this document when the remediations are available.

Schneider Electric recommends users immediately apply the following mitigations to reduce the risk of exploitation:

  • Store project files in a secure storage location and limit access to the files to only trusted users.
  • When exchanging the files over the network, use secure communication protocols.
  • Harden the workstations running EcoStruxure Control Expert, EcoStruxure Process Expert, or SCADAPack RemoteConnect.
  • Compute a checksum on all project files and check the consistency of the checksum to verify the integrity before usage.
  • Start the software without administrator rights to prevent the copying of extracted files in critical system folders.

Users still using Unity Pro should strongly consider migrating to EcoStruxure Control Expert. Please contact the local Schneider Electric technical support for more information.

To stay informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:

  • Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet.
  • Locate control system networks and remote devices behind firewalls, and isolate them from the business network.
  • When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploits specifically target this vulnerability. This vulnerability is not exploitable remotely.

References

CVSS2

9.3

Attack Vector

NETWORK

Attack Complexity

MEDIUM

Authentication

NONE

Confidentiality Impact

COMPLETE

Integrity Impact

COMPLETE

Availability Impact

COMPLETE

AV:N/AC:M/Au:N/C:C/I:C/A:C

CVSS3

7.8

Attack Vector

LOCAL

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

REQUIRED

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

AI Score

8

Confidence

High

EPSS

0.002

Percentile

58.9%

Related for ICSA-21-259-02