Lucene search
K

Siemens SINAMICS Medium Voltage Products Telnet (Update A)

🗓️ 11 May 2021 00:00:00Reported by Industrial Control Systems Cyber Emergency Response TeamType 
ics
 ics
🔗 www.cisa.gov👁 54 Views

Siemens SINAMICS Medium Voltage Products Telnet (Update A) CVSS v3 8.1, Exploitable remotely, Missing Authentication for Critical Function, Gain full remote access to the HMI, Telnet service not requiring authentication, CVE-2020-15798 assigned, HMI image versions prior to v16 Update 3a affected, Telnet should be disabled, SINAMICS MV industrial security guidelines, Protect network access, Configure environment according to Siemens’ operational guidelines for industrial security