CVSS2
Attack Vector
NETWORK
Attack Complexity
MEDIUM
Authentication
NONE
Confidentiality Impact
PARTIAL
Integrity Impact
PARTIAL
Availability Impact
PARTIAL
AV:N/AC:M/Au:N/C:P/I:P/A:P
CVSS3
Attack Vector
LOCAL
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
REQUIRED
Scope
UNCHANGED
Confidentiality Impact
HIGH
Integrity Impact
HIGH
Availability Impact
HIGH
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
AI Score
Confidence
High
EPSS
Percentile
58.8%
Successful exploitation of these vulnerabilities could allow an attacker to execute code under the privileges of the application.
The following Fuji Electric products are affected:
Multiple stack-based buffer overflow issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution.
CVE-2021-22637 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
Multiple out-of-bounds read issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution.
CVE-2021-22655 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
Multiple out-of-bounds write issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution.
CVE-2021-22653 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
An uninitialized pointer issue has been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution.
CVE-2021-22639 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
A heap-based buffer overflow issue has been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution.
CVE-2021-22641 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
Kimiya, Khangkito β Tran Van Khang of VinCSS (Member of Vingroup), and an anonymous researcher, working with Trend Microβs Zero Day Initiative, reported these vulnerabilities to CISA.
Fuji Electric recommends updating to the current version v4.0.10.0. Both disks are required for updating. Login is required to download the files.
CISA recommends users take the following measures to protect themselves from social engineering attacks:
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on us-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01BβTargeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.
No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.
web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-22637
web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-22639
web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-22641
web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-22653
web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-22655
cisasurvey.gov1.qualtrics.com/jfe/form/SV_9n4TtB8uttUPaM6?product=https://www.cisa.gov/news-events/ics-advisories/icsa-21-026-01
cwe.mitre.org/data/definitions/121.html
cwe.mitre.org/data/definitions/122.html
cwe.mitre.org/data/definitions/125.html
cwe.mitre.org/data/definitions/787.html
cwe.mitre.org/data/definitions/824.html
felib.fujielectric.co.jp/download/details.htm?dataid=43821668&site=global&lang=en
felib.fujielectric.co.jp/download/details.htm?dataid=43821669&site=global&lang=en
public.govdelivery.com/accounts/USDHSCISA/subscriber/new?topic_id=USDHSCISA_138
twitter.com/CISAgov
twitter.com/intent/tweet?text=Fuji%20Electric%20Tellus%20Lite%20V-Simulator%20and%20V-Server%20Lite+https://www.cisa.gov/news-events/ics-advisories/icsa-21-026-01
us-cert.cisa.gov/ics
us-cert.cisa.gov/ics
us-cert.cisa.gov/ics/recommended-practices
us-cert.cisa.gov/ics/tips/ICS-TIP-12-146-01B
us-cert.cisa.gov/ncas/tips/ST04-014
us-cert.cisa.gov/sites/default/files/publications/emailscams_0905.pdf
us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf
www.dhs.gov
www.dhs.gov/foia
www.dhs.gov/performance-financial-reports
www.facebook.com/CISA
www.facebook.com/sharer/sharer.php?u=https://www.cisa.gov/news-events/ics-advisories/icsa-21-026-01&title=Fuji%20Electric%20Tellus%20Lite%20V-Simulator%20and%20V-Server%20Lite
www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
www.instagram.com/cisagov
www.linkedin.com/company/cybersecurity-and-infrastructure-security-agency
www.linkedin.com/sharing/share-offsite/?url=https://www.cisa.gov/news-events/ics-advisories/icsa-21-026-01
www.oig.dhs.gov/
www.usa.gov/
www.whitehouse.gov/
www.youtube.com/@cisagov
mailto:?subject=Fuji%20Electric%20Tellus%20Lite%20V-Simulator%20and%20V-Server%20Lite&body=www.cisa.gov/news-events/ics-advisories/icsa-21-026-01
CVSS2
Attack Vector
NETWORK
Attack Complexity
MEDIUM
Authentication
NONE
Confidentiality Impact
PARTIAL
Integrity Impact
PARTIAL
Availability Impact
PARTIAL
AV:N/AC:M/Au:N/C:P/I:P/A:P
CVSS3
Attack Vector
LOCAL
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
REQUIRED
Scope
UNCHANGED
Confidentiality Impact
HIGH
Integrity Impact
HIGH
Availability Impact
HIGH
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
AI Score
Confidence
High
EPSS
Percentile
58.8%