Lucene search

K
ibmIBMFE1FCF1D7AD245BC576015B18F2B7A69A6F015697F6739F395AE8969022E85D9
HistoryMar 24, 2022 - 7:09 p.m.

Security Bulletin: Multiple vulnerabilities in IBM Java SDK affect IBM Spectrum Control and Tivoli Storage Productivity Center April 2016 CPU (CVE-2016-3426)

2022-03-2419:09:20
www.ibm.com
16
ibm spectrum control
tivoli storage productivity center
ibm java sdk
vulnerabilities
critical patch update
cve-2016-3426
jce component
remote attacker
confidentiality impact
download
security bulletin
affected versions
remediation
uninstall
backup

EPSS

0.007

Percentile

80.3%

Summary

There are multiple vulnerabilities in IBM® SDK Java™ Technology Edition and IBM® Runtime Environment Java™ Technology Edition that is shipped and used by IBM Spectrum Control and Tivoli Storage Productivity Center. These issues were disclosed as part of the IBM Java SDK updates in April 2016.

Vulnerability Details

Vulnerabilities disclosed in the April 2016 Critical Patch Update

CVEID: CVE-2016-3426** *DESCRIPTION: An unspecified vulnerability related to the JCE component could allow a remote attacker to obtain sensitive information resulting in a partial confidentiality impact using unknown attack vectors.
CVSS Base Score: 4.3
CVSS Temporal Score: See https://exchange.xforce.ibmcloud.com/vulnerabilities/112457 for the current score
CVSS Environmental Score
: Undefined
CVSS Vector: (AV:N/AC:M/Au:N/C:P/I:N/A:N)

The IBM® Runtime Environment Java™ Technology Edition provided for download with Tivoli Storage Productivity Center 5.1.x and 5.2.0 through 5.2.7.1, which can be installed separately, is vulnerable to all CVEs as noted by the IBM Java SDK security bulletin. Review the following security bulletin** **and evaluate your own code to determine if you are vulnerable.
Security Bulletin: Multiple vulnerabilities in current releases of the IBM® SDK, Java™ Technology Edition (April 2016 CPU)

Document link ‘Importing HTML’.

Affected Products and Versions

IBM Spectrum Control 5.2.8 through 5.2.10.1
Tivoli Storage Productivity Center 5.2.0 through 5.2.7.1
Tivoli Storage Productivity Center 5.1.0 through 5.1.1.10
Tivoli Storage Productivity Center 4.2.x
Tivoli Storage Productivity Center 4.1.x
TotalStorage Productivity Center 3.3.x

The versions listed above apply to all licensed offerings of IBM Spectrum Control and Tivoli Storage Productivity Center, including IBM SmartCloud Virtual Storage Center Storage Analytics Engine.

System Storage Productivity Center is affected if it has one of the Tivoli Storage Productivity Center versions listed above installed on it.

Remediation/Fixes

The solution is to apply an appropriate Tivoli Storage Productivity Center fix maintenance for each named product and execute the manual steps listed below. The solution should be implemented as soon as practicable. Starting with 5.2.8, Tivoli Storage Productivity Center has been renamed to IBM Spectrum Control.

If you have downloaded and installed IBM® Runtime Environment Java™ Technology Edition, Version 6 Service Refresh 16 Fix Pack 21 or earlier from an older version of Tivoli Storage Productivity Center, you should uninstall it or download an updated version after applying the fix pack and reinstall IBM® Runtime Environment Java™ Technology Edition, Version 6 Service Refresh 16 Fix Pack 25 or later. Do not use the IBM JRE 1.6.0 or IBM SDK 1.6.0 links provided with the affected Tivoli Storage Productivity Center versions. If you upgrade to IBM Spectrum Control 5.2.8 or higher, there is no new version to download and apply as the Java WebStart GUI that previously used it is no longer provided.

Note: It is always recommended to have a current backup before applying any update procedure.

< /br >

IBM Spectrum Control 5.2.x and Tivoli Storage Productivity Center V5.2.x

Affected Version APAR Fixed Version Availability
5.2.x IT16545 5.2.11 August 2016
Apply fix maintenance V5.2.11 as soon as practicable. (See Latest Downloads)

< /br >

Tivoli Storage Productivity Center V5.1.x

Affected Version APAR Fixed Version Availability
5.1.x IT16545 5.1.1.11

Manual update steps are required in addition to applying 5.1.1.11| July 2016
Apply fix maintenance V5.1.1.11 as soon as practicable. (See Latest Downloads)

These manual steps are required in addition to applying the V5.1.1.11 fixpack:

Tivoli Integrated Portal embeds Websphere Application Server 7.0 and requires an ifix. Follow these steps to apply the fix:

  1. Download Websphere iFix PI61191for WAS 7.0.0.X ** **
    <http://www-01.ibm.com/support/docview.wss?uid=swg24042133&gt;

  2. Apply the WebSphere Application Server 7.0 ifix to Tivoli Integrated Portal using the preinstalled WAS Update Installer

_ On Windows, the default location for __WAS Update Installer _is:
[TPC_Install_Location]\IBM\tipv2\WebSphereUpdateInstallerV7\

< /br >

Tivoli Storage Productivity Center V4.2.x, 4.1.x and TotalStorage Productivity Center 3.3.x
For these releases, IBM recommends upgrading to a fixed, supported release of the product.

< /br >

Workarounds and Mitigations

None