HistoryDec 07, 2021 - 7:14 p.m.

Security Bulletin: This Power System update is being released to address CVE 2018-1992

2021-12-0719:14:45
www.ibm.com
7
power system
firmware update
buffer overflow
vulnerability
cve 2018-1992
ibm
boot loader
bootloader
security
patch
power9
openpower
firmware release
affected products
remediation

EPSS

0

Percentile

12.6%

Summary

POWER9: In response to a buffer overflow vulnerability on the boot loader, a new Power System firmware update is being released to address Common Vulnerabilities and Exposures issue number CVE 2018-1992.

Vulnerability Details

CVEID: ****CVE-2018-1992

DESCRIPTION: The IBM POWER9 boot firmware’s bootloader is responsible for loading and validating the initial boot firmware image that drives the rest of the system’s hardware initialization. The bootloader firmware contains a buffer overflow vulnerability such that, if an attacker were able to replace the initial boot firmware image with a very carefully crafted and sufficiently large, malicious replacement, it could cause the bootloader, during the load of that image, to overwrite its own instruction memory and circumvent secure boot protections, install trojans, etc. The firmware mitigation adds additional checking of the initial boot firmware image’s load size and terminates the boot if the size is too big.
CVSS Base Score: 6.4
CVSS Temporal Score: See <https://exchange.xforce.ibmcloud.com/vulnerabilities/154345&gt;

for the current score
CVSS Environmental Score*: Undefined
CVSS Vector: (CVSS:3.0/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H)

The firmware update can be obtained from _ FixCentral_ by specifying the Product and fix level as specified in this Remediation section.

Affected Products and Versions

Firmware release FW910 is affected.

P9 OpenPOWER releases OP910 and OP920 are affected.

Remediation/Fixes

Customers with the products below, install FW910.10 or above.

  1. IBM Power System S922 (9009-22A)

  2. IBM Power System H922 (9223-22H)

  3. IBM Power System S914 (9009-41A)

  4. IBM Power System S924 (9009-42A)

  5. IBM Power System H924 (9223-42H)

  6. IBM Power System L922 (9008-22L)

Customers with the products below running OP910, install OP910.30

  1. IBM Power System AC922 (8335-GTG)

Customers with the products below running OP910, install OP910.31

  1. IBM Power System AC922 (8335-GTC)

  2. IBM Power System AC922 (8335-GTW)

Customers with the product below running OP910, install V0.55.1-20190503/BMC 2.06

  1. IBM Power System LC922 (9006-22C)

  2. IBM Power System LC922 (5104-22C)

Customers with the products below running OP920, install V2.10-20190208/ OP920.10/BMC 2.04

  1. IBM Power System LC921 (9006-12P)

  2. IBM Power System LC922 (9006-22P)