POWER8/POWER9: In response to a security bypass vulnerability, a new Power System firmware update is being released to address Common Vulnerabilities and Exposures issue number CVE-2018-8931.
CVEID: ****CVE-2018-8931
DESCRIPTION: The AMD Ryzen, Ryzen Pro, and Ryzen Mobile processor chips have insufficient access control for the Secure Processor, aka RYZENFALL-1.
CVSS Base Score: 6.0
CVSS Temporal Score: See https://exchange.xforce.ibmcloud.com/vulnerabilities/140293 for the current score
CVSS Environmental Score*: Undefined
CVSS Vector: (CVSS:3.0/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H)
The firmware update can be obtained from _ FixCentral_ by specifying the Product and fix level as specified in this Remediation section.
Firmware releases FW810, FW840, FW860 are affected - if in OPAL mode.
P9 OpenPOWER release OP910 is affected.
P8 OpenPOWER release OP810, OP815, OP820 and OP825 are affected.
Customers with the products below running 810, 840 or 860, install SP 860.60 (for OPAL mode).
1. IBM Power System S812L (8247-21L)
2. IBM Power System S822L (8247-22L)
3. IBM Power System S824L (8247-42L)
4. IBM Power System S812 (8284-21A)
5. IBM Power System S814 (8286-41A)
6. IBM Power System S824 (8286-42A)
7. IBM Power System S812L (5148-21L)
8. IBM Power System S822L (5148-22L)
Customers with the products below running OP910, install OP910.30
Customers with the products below running OP910, install OP910.31
IBM Power System AC922 (8335-GTC)
IBM Power System AC922 (8335-GTW)
Customers with the product below running OP910, install OP910.32 - V0.55.1-20190503/BMC 2.06
IBM Power System LC922 (9006-22C)
IBM Power System LC922 (5104-22C)
Customer with the products below running OP810 or OP820, install OP820.30 - OP8_v1.12 2.96_H
Customer with the products below running OP820, install OP820.30 - OP8_v1.12 2.96_G
1)IBM Power System S822LC (8335-GTB)
Customer with the products below running OP825, install OP825.30 - v3.07_hmc
Customer with the products below running OP815 or OP825, install OP825.30 - v3.07
IBM Power System S821LC (8001-12C)
IBM Power System S822LC (8001-22C)
Customer with the products below running OP825, install OP825.41 -v3.09
IBM Power Hyperconverged Systems with Nutanix CS821(8005-12N)
IBM Power Hyperconverged Systems with Nutanix CS822 (8005-22N)