| The vulnerability of the WAGO Device Manager software in terms of controller configuration and parameter setting lies in the lack of authentication for critical functions. This allows attackers to gain unauthorized access to the file system. | 19 Jun 202500:00 | – | bdu_fstec | |
| CVE-2025-25265 | 16 Jun 202510:33 | – | circl | |
| WAGO Device Manager 访问控制错误漏洞 | 16 Jun 202500:00 | – | cnnvd | |
| CVE-2025-25265 | 16 Jun 202509:46 | – | cve | |
| CVE-2025-25265 Unauthenticated File Read via Web Interface | 16 Jun 202509:46 | – | cvelist | |
| CVE-2025-25265 | 16 Jun 202510:15 | – | nvd | |
| PT-2025-25540 · Wago +1 · Cc100 0751-9X01 +17 | 13 Jun 202500:00 | – | ptsecurity | |
| CVE-2025-25265 | 18 Jun 202510:21 | – | redhatcve | |
| CVE-2025-25265 Unauthenticated File Read via Web Interface | 16 Jun 202509:46 | – | vulnrichment |
[
{
"enisaIdVendor": [
{
"id": "f0122d78-7305-3103-913c-e96319f7230d",
"vendor": {
"name": "WAGO"
}
}
],
"enisaIdProduct": [
{
"id": "0013029c-99b3-39cf-aca4-fdf5fb8efdcc",
"product": {
"name": "TP600 0762-420x/8000-000x"
},
"product_version": "0.0.0 <04.07.01 (FW29)"
},
{
"id": "049a505f-4be4-37ba-907b-203382cb5a39",
"product": {
"name": "PFC100 G1 0750-810x/xxxx-xxxx"
},
"product_version": "0.0.0 <03.10.11 (70)"
},
{
"id": "1782f539-2f10-3c08-8a2b-5936c0afaed2",
"product": {
"name": "Edge Controller 0752-8303/8000-0002"
},
"product_version": "0.0.0 <04.07.01 (70)"
},
{
"id": "217e5acc-d5eb-39c3-83db-256f4b1f01f6",
"product": {
"name": "WAGO CC100 0751-9x01"
},
"product_version": "0.0.0 <04.07.01 (FW29)"
},
{
"id": "27a5ef9b-4875-38da-b49e-3a580e72bb2c",
"product": {
"name": "PFC200 G1 750-820x-xxx-xxx"
},
"product_version": "0.0.0 ≤3.10.11 (FW22 Patch 2)"
},
{
"id": "2c205afc-2a8d-36ff-8e82-9e6c0169d823",
"product": {
"name": "PFC100 G2 0750-811x-xxxx-xxxx"
},
"product_version": "0.0.0 <04.07.01 (FW29)"
},
{
"id": "2eb7dde8-bad1-383a-b1b2-9b7ca7a5be24",
"product": {
"name": "PFC200 G2 750-821x-xxx-xxx"
},
"product_version": "0.0.0 <04.07.01 (FW29)"
},
{
"id": "3b0266d5-37a4-35b4-8549-4f2e81fd46ca",
"product": {
"name": "TP600 0762-630x/8000-000x"
},
"product_version": "0.0.0 <04.07.01 (70)"
},
{
"id": "3c55d070-d437-3d3d-8894-47befb797b50",
"product": {
"name": "TP600 0762-630x/8000-000x"
},
"product_version": "0.0.0 <04.07.01 (FW29)"
},
{
"id": "4d513fcf-6a51-336f-aaf9-5e4297aa913e",
"product": {
"name": "PFC200 G1 750-820x-xxx-xxx"
},
"product_version": "0.0.0 <03.10.11 (70)"
},
{
"id": "6478dfdd-4989-3f25-b28c-4ff5089b5546",
"product": {
"name": "TP600 0762-520x/8000-000x"
},
"product_version": "0.0.0 <04.07.01 (FW29)"
},
{
"id": "824e6432-4054-3b81-85e2-283a7c7eab25",
"product": {
"name": "TP600 0762-420x/8000-000x"
},
"product_version": "0.0.0 <04.07.01 (70)"
},
{
"id": "8cdde68e-a910-3c19-b76a-7754e1ef62d3",
"product": {
"name": "TP600 0762-620x/8000-000x"
},
"product_version": "0.0.0 <04.07.01 (70)"
},
{
"id": "92db8552-f4ca-375e-8895-e0023d299966",
"product": {
"name": "PFC200 G2 750-821x-xxx-xxx"
},
"product_version": "0.0.0 <04.07.01 (70)"
},
{
"id": "968e7c07-a3e8-3a6a-b7d1-147340378d18",
"product": {
"name": "TP600 0762-530x/8000-000x"
},
"product_version": "0.0.0 <04.07.01 (70)"
},
{
"id": "9fd8ad4b-e0f1-3f8d-ad7a-1e0d1976c29c",
"product": {
"name": "Edge Controller 0752-8303/8000-0002"
},
"product_version": "0.0.0 <04.07.01 (FW29)"
},
{
"id": "ad473e8a-2b69-37fa-8cab-1fe4217ff761",
"product": {
"name": "TP600 0762-430x/8000-000x"
},
"product_version": "0.0.0 <04.07.01 (70)"
},
{
"id": "ae37cbbd-4bb7-30c4-b09e-fa711e0eb422",
"product": {
"name": "TP600 0762-430x/8000-000x"
},
"product_version": "0.0.0 <04.07.01 (FW29)"
},
{
"id": "c0e2313d-6343-3166-b7dc-5be5e0c99e15",
"product": {
"name": "TP600 0762-620x/8000-000x"
},
"product_version": "0.0.0 <04.07.01 (FW29)"
},
{
"id": "d3a14bbe-e0b5-33cf-835a-1d4cf38b00d3",
"product": {
"name": "TP600 0762-530x/8000-000x"
},
"product_version": "0.0.0 <04.07.01 (FW29)"
},
{
"id": "db02177b-7a2a-33bb-acdc-1febe25ad13f",
"product": {
"name": "TP600 0762-520x/8000-000x"
},
"product_version": "0.0.0 <04.07.01 (70)"
},
{
"id": "e47d10a2-dffb-329c-80bb-be962998b8bd",
"product": {
"name": "PFC100 G1 0750-810x/xxxx-xxxx"
},
"product_version": "0.0.0 <3.10.11 (FW22 Patch 2)"
},
{
"id": "ea45f954-6e89-31e5-bd19-56c0ad9bfdfc",
"product": {
"name": "CC100 0751-9x01"
},
"product_version": "0.0.0 <04.07.01 (70)"
},
{
"id": "f17734d8-59fc-307a-bd07-fd5aee4d68d5",
"product": {
"name": "PFC200 G1 750-820x-xxx-xxx"
},
"product_version": "0.0.0 <3.10.11 (FW22 Patch 2)"
},
{
"id": "f64cca8b-a368-38d3-bc5a-7e5cdc99e9d1",
"product": {
"name": "PFC100 G2 0750-811x-xxxx-xxxx"
},
"product_version": "0.0.0 <04.07.01 (70)"
}
]
}
]Data
Build on a solid foundation with Vulners data
We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data
Api
Power your application with Vulners API
The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access
App
Assess and manage vulnerabilities with Vulners tools
Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation