Vulnerability found in multiple SIMATIC S7-1200 and SMART CPU models allowing unauthorized access.

Related
Affected
Refs
[
  {
    "enisaIdVendor": [
      {
        "id": "d7cd3302-0d7b-33a5-b1b8-1fa6b31305ea",
        "vendor": {
          "name": "Siemens AG"
        }
      }
    ],
    "enisaIdProduct": [
      {
        "id": "1722d829-310a-398a-bfc6-e0e1dc851515",
        "product": {
          "name": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)"
        },
        "product_version": "All versions"
      },
      {
        "id": "183a3f55-8618-3a68-965c-881feb5dd0ac",
        "product": {
          "name": "SIMATIC S7-200 SMART CPU CR60s (6ES7 288-1CR60-0AA1)"
        },
        "product_version": "All versions ≤ V2.3.0 and Function State (FS) ≤ 3"
      },
      {
        "id": "1a9a7857-7acd-3b69-9bc4-83401fb9bb0e",
        "product": {
          "name": "SIMATIC S7-200 SMART CPU family"
        },
        "product_version": "All versions"
      },
      {
        "id": "338d1422-1317-355c-8f01-2fe02339ddf4",
        "product": {
          "name": "SIMATIC S7-200 SMART CPU SR60 (6ES7 288-1SR60-0AA0)"
        },
        "product_version": "All versions ≤ V2.5.0 and Function State (FS) ≤ 12"
      },
      {
        "id": "448f6bc1-b68a-3eb9-b282-d22e086477d2",
        "product": {
          "name": "SIMATIC S7-1200 CPU family < V4.x (incl. SIPLUS variants)"
        },
        "product_version": "All versions"
      },
      {
        "id": "57d01f6f-8954-340d-a775-670661da3f1c",
        "product": {
          "name": "SIMATIC S7-1200 CPU family V4.x (incl. SIPLUS variants)"
        },
        "product_version": "All versions with Function State (FS) < 11"
      },
      {
        "id": "5e3bce51-54e4-3251-aa92-ef7c8a23c827",
        "product": {
          "name": "SIMATIC S7-200 SMART CPU ST20 (6ES7 288-1ST20-0AA0)"
        },
        "product_version": "All versions ≤ V2.5.0 and Function State (FS) ≤ 9"
      },
      {
        "id": "5e44a70d-9a64-3a13-a096-e2c51210ae49",
        "product": {
          "name": "SIMATIC S7-200 SMART CPU ST60 (6ES7 288-1ST60-0AA0)"
        },
        "product_version": "All versions ≤ V2.5.0 and Function State (FS) ≤ 8"
      },
      {
        "id": "7bfb944f-deca-3fe9-b16c-f0f020fec10f",
        "product": {
          "name": "SIMATIC S7-200 SMART CPU SR30 (6ES7 288-1SR30-0AA0)"
        },
        "product_version": "All versions ≤ V2.5.0 and Function State (FS) ≤ 10"
      },
      {
        "id": "894d4534-1e05-37f5-8d38-84b3eab8d618",
        "product": {
          "name": "SIMATIC S7-200 SMART CPU ST30 (6ES7 288-1ST30-0AA0)"
        },
        "product_version": "All versions ≤ V2.5.0 and Function State (FS) ≤ 9"
      },
      {
        "id": "92004650-2acd-30d0-929d-a64504128f81",
        "product": {
          "name": "SIMATIC S7-200 SMART CPU SR40 (6ES7 288-1SR40-0AA0)"
        },
        "product_version": "All versions ≤ V2.5.0 and Function State (FS) ≤ 10"
      },
      {
        "id": "92233c8c-366f-3524-b6f6-94e3bc3b6026",
        "product": {
          "name": "SIMATIC S7-200 SMART CPU CR40s (6ES7 288-1CR40-0AA1)"
        },
        "product_version": "All versions ≤ V2.3.0 and Function State (FS) ≤ 3"
      },
      {
        "id": "9b342497-7b6e-30c9-9c9e-dd85ff379dce",
        "product": {
          "name": "SIMATIC S7-200 SMART CPU CR60 (6ES7 288-1CR60-0AA0)"
        },
        "product_version": "All versions ≤ V2.2.2 and Function State (FS) ≤ 10"
      },
      {
        "id": "9c168e1b-ee0b-3b12-bd13-6337e339e0e1",
        "product": {
          "name": "SIMATIC S7-200 SMART CPU CR30s (6ES7 288-1CR30-0AA1)"
        },
        "product_version": "All versions ≤ V2.3.0 and Function State (FS) ≤ 3"
      },
      {
        "id": "aa028fa0-3926-3ed6-bba7-e12449a5ae3a",
        "product": {
          "name": "SIMATIC S7-200 SMART CPU ST40 (6ES7 288-1ST40-0AA0)"
        },
        "product_version": "All versions ≤ V2.5.0 and Function State (FS) ≤ 8"
      },
      {
        "id": "aea661d9-2a28-3bc8-a2e6-35b0839eaa93",
        "product": {
          "name": "SIMATIC S7-200 SMART CPU CR20s (6ES7 288-1CR20-0AA1)"
        },
        "product_version": "All versions ≤ V2.3.0 and Function State (FS) ≤ 3"
      },
      {
        "id": "b05c22d7-79bb-3572-87a1-495d182dfb41",
        "product": {
          "name": "SIMATIC S7-200 SMART CPU CR40 (6ES7 288-1CR40-0AA0)"
        },
        "product_version": "All versions ≤ V2.2.2 and Function State (FS) ≤ 8"
      },
      {
        "id": "e35dadf9-fce1-3c37-bb1d-05a404d8dcf2",
        "product": {
          "name": "SIMATIC S7-200 SMART CPU SR20 (6ES7 288-1SR20-0AA0)"
        },
        "product_version": "All versions ≤ V2.5.0 and Function State (FS) ≤ 11"
      }
    ]
  }
]

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation

07 Oct 2025 00:30Current
6.5Medium risk
Vulners AI Score6.5
CVSS 3.16.8
CVSS 24.6
EPSS0.00528
5