8.8 High
CVSS3
Attack Vector
NETWORK
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
REQUIRED
Scope
UNCHANGED
Confidentiality Impact
HIGH
Integrity Impact
HIGH
Availability Impact
HIGH
CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
0.001 Low
EPSS
Percentile
30.9%
Voltronic Power ViewPower USBCommEx shutdown Command Injection Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Voltronic Power ViewPower Pro. User interaction is required to exploit this vulnerability in that an administrator must trigger a shutdown operation.
The specific flaw exists within the shutdown method. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of the current user. Was ZDI-CAN-22071.
[
{
"vendor": "Voltronic Power",
"product": "ViewPower",
"versions": [
{
"version": "1.04.21353",
"status": "affected"
}
],
"defaultStatus": "unknown"
}
]