8.2 High
CVSS3
Attack Vector
ADJACENT
Attack Complexity
LOW
Privileges Required
LOW
User Interaction
NONE
Scope
CHANGED
Confidentiality Impact
LOW
Integrity Impact
LOW
Availability Impact
HIGH
CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:H/E:P/RL:O/RC:C
8.3 High
AI Score
Confidence
High
0.001 Low
EPSS
Percentile
25.9%
A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT PRO (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2P IRT (All versions < V5.5.2), SCALANCE X202-2P IRT PRO (All versions < V5.5.2), SCALANCE X204-2 (All versions < V5.2.6), SCALANCE X204-2FM (All versions < V5.2.6), SCALANCE X204-2LD (All versions < V5.2.6), SCALANCE X204-2LD TS (All versions < V5.2.6), SCALANCE X204-2TS (All versions < V5.2.6), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT PRO (All versions < V5.5.2), SCALANCE X206-1 (All versions < V5.2.6), SCALANCE X206-1LD (All versions < V5.2.6), SCALANCE X208 (All versions < V5.2.6), SCALANCE X208PRO (All versions < V5.2.6), SCALANCE X212-2 (All versions < V5.2.6), SCALANCE X212-2LD (All versions < V5.2.6), SCALANCE X216 (All versions < V5.2.6), SCALANCE X224 (All versions < V5.2.6), SCALANCE XF201-3P IRT (All versions < V5.5.2), SCALANCE XF202-2P IRT (All versions < V5.5.2), SCALANCE XF204 (All versions < V5.2.6), SCALANCE XF204-2 (All versions < V5.2.6), SCALANCE XF204-2BA IRT (All versions < V5.5.2), SCALANCE XF204IRT (All versions < V5.5.2), SCALANCE XF206-1 (All versions < V5.2.6), SCALANCE XF208 (All versions < V5.2.6). Affected devices do not properly validate the GET parameter XNo of incoming HTTP requests. This could allow an unauthenticated remote attacker to crash affected devices.
[
{
"vendor": "Siemens",
"product": "SCALANCE X200-4P IRT",
"versions": [
{
"version": "All versions < V5.5.2",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE X201-3P IRT",
"versions": [
{
"version": "All versions < V5.5.2",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE X201-3P IRT PRO",
"versions": [
{
"version": "All versions < V5.5.2",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE X202-2IRT",
"versions": [
{
"version": "All versions < V5.5.2",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE X202-2IRT",
"versions": [
{
"version": "All versions < V5.5.2",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE X202-2P IRT",
"versions": [
{
"version": "All versions < V5.5.2",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE X202-2P IRT PRO",
"versions": [
{
"version": "All versions < V5.5.2",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE X204-2",
"versions": [
{
"version": "All versions < V5.2.6",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE X204-2FM",
"versions": [
{
"version": "All versions < V5.2.6",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE X204-2LD",
"versions": [
{
"version": "All versions < V5.2.6",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE X204-2LD TS",
"versions": [
{
"version": "All versions < V5.2.6",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE X204-2TS",
"versions": [
{
"version": "All versions < V5.2.6",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE X204IRT",
"versions": [
{
"version": "All versions < V5.5.2",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE X204IRT",
"versions": [
{
"version": "All versions < V5.5.2",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE X204IRT PRO",
"versions": [
{
"version": "All versions < V5.5.2",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE X206-1",
"versions": [
{
"version": "All versions < V5.2.6",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE X206-1LD",
"versions": [
{
"version": "All versions < V5.2.6",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE X208",
"versions": [
{
"version": "All versions < V5.2.6",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE X208PRO",
"versions": [
{
"version": "All versions < V5.2.6",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE X212-2",
"versions": [
{
"version": "All versions < V5.2.6",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE X212-2LD",
"versions": [
{
"version": "All versions < V5.2.6",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE X216",
"versions": [
{
"version": "All versions < V5.2.6",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE X224",
"versions": [
{
"version": "All versions < V5.2.6",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE XF201-3P IRT",
"versions": [
{
"version": "All versions < V5.5.2",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE XF202-2P IRT",
"versions": [
{
"version": "All versions < V5.5.2",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE XF204",
"versions": [
{
"version": "All versions < V5.2.6",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE XF204-2",
"versions": [
{
"version": "All versions < V5.2.6",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE XF204-2BA IRT",
"versions": [
{
"version": "All versions < V5.5.2",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE XF204IRT",
"versions": [
{
"version": "All versions < V5.5.2",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE XF206-1",
"versions": [
{
"version": "All versions < V5.2.6",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SCALANCE XF208",
"versions": [
{
"version": "All versions < V5.2.6",
"status": "affected"
}
],
"defaultStatus": "unknown"
}
]
8.2 High
CVSS3
Attack Vector
ADJACENT
Attack Complexity
LOW
Privileges Required
LOW
User Interaction
NONE
Scope
CHANGED
Confidentiality Impact
LOW
Integrity Impact
LOW
Availability Impact
HIGH
CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:H/E:P/RL:O/RC:C
8.3 High
AI Score
Confidence
High
0.001 Low
EPSS
Percentile
25.9%