A vulnerability has been identified in RUGGEDCOM i800 (All versions < V4.3.8), RUGGEDCOM i801 (All versions < V4.3.8), RUGGEDCOM i802 (All versions < V4.3.8), RUGGEDCOM i803 (All versions < V4.3.8), RUGGEDCOM M2100 (All versions < V4.3.8), RUGGEDCOM M2200 (All versions < V4.3.8), RUGGEDCOM M969 (All versions < V4.3.8), RUGGEDCOM RMC30 (All versions < V4.3.8), RUGGEDCOM RMC8388 V4.X (All versions < V4.3.8), RUGGEDCOM RMC8388 V5.X (All versions < V5.7.0), RUGGEDCOM RP110 (All versions < V4.3.8), RUGGEDCOM RS1600 (All versions < V4.3.8), RUGGEDCOM RS1600F (All versions < V4.3.8), RUGGEDCOM RS1600T (All versions < V4.3.8), RUGGEDCOM RS400 (All versions < V4.3.8), RUGGEDCOM RS401 (All versions < V4.3.8), RUGGEDCOM RS416 (All versions < V4.3.8), RUGGEDCOM RS416P (All versions < V4.3.8), RUGGEDCOM RS416Pv2 V4.X (All versions < V4.3.8), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.7.0), RUGGEDCOM RS416v2 V4.X (All versions < V4.3.8), RUGGEDCOM RS416v2 V5.X (All versions < V5.7.0), RUGGEDCOM RS8000 (All versions < V4.3.8), RUGGEDCOM RS8000A (All versions < V4.3.8), RUGGEDCOM RS8000H (All versions < V4.3.8), RUGGEDCOM RS8000T (All versions < V4.3.8), RUGGEDCOM RS900 (All versions < V4.3.8), RUGGEDCOM RS900 (32M) V4.X (All versions < V4.3.8), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.7.0), RUGGEDCOM RS900G (All versions < V4.3.8), RUGGEDCOM RS900G (32M) V4.X (All versions < V4.3.8), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.7.0), RUGGEDCOM RS900GP (All versions < V4.3.8), RUGGEDCOM RS900L (All versions < V4.3.8), RUGGEDCOM RS900M-GETS-C01 (All versions < V4.3.8), RUGGEDCOM RS900M-GETS-XX (All versions < V4.3.8), RUGGEDCOM RS900M-STND-C01 (All versions < V4.3.8), RUGGEDCOM RS900M-STND-XX (All versions < V4.3.8), RUGGEDCOM RS900W (All versions < V4.3.8), RUGGEDCOM RS910 (All versions < V4.3.8), RUGGEDCOM RS910L (All versions < V4.3.8), RUGGEDCOM RS910W (All versions < V4.3.8), RUGGEDCOM RS920L (All versions < V4.3.8), RUGGEDCOM RS920W (All versions < V4.3.8), RUGGEDCOM RS930L (All versions < V4.3.8), RUGGEDCOM RS930W (All versions < V4.3.8), RUGGEDCOM RS940G (All versions < V4.3.8), RUGGEDCOM RS969 (All versions < V4.3.8), RUGGEDCOM RSG2100 (All versions < V4.3.8), RUGGEDCOM RSG2100 (32M) V4.X (All versions < V4.3.8), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.7.0), RUGGEDCOM RSG2100P (All versions < V4.3.8), RUGGEDCOM RSG2200 (All versions < V4.3.8), RUGGEDCOM RSG2288 V4.X (All versions < V4.3.8), RUGGEDCOM RSG2288 V5.X (All versions < V5.7.0), RUGGEDCOM RSG2300 V4.X (All versions < V4.3.8), RUGGEDCOM RSG2300 V5.X (All versions < V5.7.0), RUGGEDCOM RSG2300P V4.X (All versions < V4.3.8), RUGGEDCOM RSG2300P V5.X (All versions < V5.7.0), RUGGEDCOM RSG2488 V4.X (All versions < V4.3.8), RUGGEDCOM RSG2488 V5.X (All versions < V5.7.0), RUGGEDCOM RSG907R (All versions < V5.7.0), RUGGEDCOM RSG908C (All versions < V5.7.0), RUGGEDCOM RSG909R (All versions < V5.7.0), RUGGEDCOM RSG910C (All versions < V5.7.0), RUGGEDCOM RSG920P V4.X (All versions < V4.3.8), RUGGEDCOM RSG920P V5.X (All versions < V5.7.0), RUGGEDCOM RSL910 (All versions < V5.7.0), RUGGEDCOM RST2228 (All versions < V5.7.0), RUGGEDCOM RST2228P (All versions < V5.7.0), RUGGEDCOM RST916C (All versions < V5.7.0), RUGGEDCOM RST916P (All versions < V5.7.0). The SSH server on affected devices is configured to offer weak ciphers by default.

This could allow an unauthorized attacker in a man-in-the-middle position to read and modify any data passed over the connection between legitimate clients and the affected device.

CNA Affected

[
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM i800",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM i801",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM i802",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM i803",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM M2100",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM M2200",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM M969",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RMC30",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RMC8388 V4.X",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RMC8388 V5.X",
    "versions": [
      {
        "version": "All versions < V5.7.0",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RP110",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS1600",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS1600F",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS1600T",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS400",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS401",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS416",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS416P",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS416Pv2 V4.X",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS416Pv2 V5.X",
    "versions": [
      {
        "version": "All versions < V5.7.0",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS416v2 V4.X",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS416v2 V5.X",
    "versions": [
      {
        "version": "All versions < V5.7.0",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS8000",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS8000A",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS8000H",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS8000T",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS900",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS900 (32M) V4.X",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS900 (32M) V5.X",
    "versions": [
      {
        "version": "All versions < V5.7.0",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS900G",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS900G (32M) V4.X",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS900G (32M) V5.X",
    "versions": [
      {
        "version": "All versions < V5.7.0",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS900GP",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS900L",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS900M-GETS-C01",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS900M-GETS-XX",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS900M-STND-C01",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS900M-STND-XX",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS900W",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS910",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS910L",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS910W",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS920L",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS920W",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS930L",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS930W",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS940G",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS969",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RSG2100",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RSG2100 (32M) V4.X",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RSG2100 (32M) V5.X",
    "versions": [
      {
        "version": "All versions < V5.7.0",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RSG2100P",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RSG2200",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RSG2288 V4.X",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RSG2288 V5.X",
    "versions": [
      {
        "version": "All versions < V5.7.0",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RSG2300 V4.X",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RSG2300 V5.X",
    "versions": [
      {
        "version": "All versions < V5.7.0",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RSG2300P V4.X",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RSG2300P V5.X",
    "versions": [
      {
        "version": "All versions < V5.7.0",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RSG2488 V4.X",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RSG2488 V5.X",
    "versions": [
      {
        "version": "All versions < V5.7.0",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RSG907R",
    "versions": [
      {
        "version": "All versions < V5.7.0",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RSG908C",
    "versions": [
      {
        "version": "All versions < V5.7.0",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RSG909R",
    "versions": [
      {
        "version": "All versions < V5.7.0",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RSG910C",
    "versions": [
      {
        "version": "All versions < V5.7.0",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RSG920P V4.X",
    "versions": [
      {
        "version": "All versions < V4.3.8",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RSG920P V5.X",
    "versions": [
      {
        "version": "All versions < V5.7.0",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RSL910",
    "versions": [
      {
        "version": "All versions < V5.7.0",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RST2228",
    "versions": [
      {
        "version": "All versions < V5.7.0",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RST2228P",
    "versions": [
      {
        "version": "All versions < V5.7.0",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RST916C",
    "versions": [
      {
        "version": "All versions < V5.7.0",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RST916P",
    "versions": [
      {
        "version": "All versions < V5.7.0",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  }
]

CVSS3

6.7

Attack Vector

ADJACENT

Attack Complexity

HIGH

Privileges Required

NONE

User Interaction

REQUIRED

Scope

UNCHANGED

Confidentiality Impact

LOW

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:H/E:P/RL:U/RC:C

AI Score

6.3

Confidence

High

EPSS

0.001

Percentile

17.1%

Related for CVELIST:CVE-2021-37209