Lucene search

K
cvelistSiemensCVELIST:CVE-2021-37185
HistoryFeb 09, 2022 - 3:16 p.m.

CVE-2021-37185

2022-02-0915:16:44
CWE-672
siemens
www.cve.org

7.5 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

NONE

Integrity Impact

NONE

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C

0.001 Low

EPSS

Percentile

40.5%

A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations.

CNA Affected

[
  {
    "vendor": "Siemens",
    "product": "SIMATIC Drive Controller family",
    "versions": [
      {
        "version": "All versions >= V2.9.2 < V2.9.4",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
    "versions": [
      {
        "version": "All versions >= V21.9 < V21.9.4",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
    "versions": [
      {
        "version": "All versions >= V4.5.0 < V4.5.2",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
    "versions": [
      {
        "version": "All versions >= V2.9.2 < V2.9.4",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "SIMATIC S7-1500 Software Controller",
    "versions": [
      {
        "version": "All versions >= V21.9 < V21.9.4",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "SIMATIC S7-PLCSIM Advanced",
    "versions": [
      {
        "version": "All versions >= V4.0 < V4.0 SP1",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "SIPLUS TIM 1531 IRC",
    "versions": [
      {
        "version": "All versions < V2.3.6",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "TIM 1531 IRC",
    "versions": [
      {
        "version": "All versions < V2.3.6",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  }
]

7.5 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

NONE

Integrity Impact

NONE

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C

0.001 Low

EPSS

Percentile

40.5%

Related for CVELIST:CVE-2021-37185