9.8 High
AI Score
Confidence
High
0.006 Low
EPSS
Percentile
78.1%
Hardcoded default root credentials exist on the ecobee3 lite 4.5.81.200 device. This allows a threat actor to gain access to the password-protected bootloader environment through the serial console.
www.l9group.com/advisories/hard-coded-default-root-credentials-for-all-ecobee3-lite-devices