Lucene search

K
cvelistJuniperCVELIST:CVE-2020-1638
HistoryApr 08, 2020 - 12:00 a.m.

CVE-2020-1638 Junos OS & Junos OS Evolved: A specific IPv4 packet can lead to FPC restart.

2020-04-0800:00:00
CWE-467
juniper
www.cve.org

7.5 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

NONE

Integrity Impact

NONE

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

0.001 Low

EPSS

Percentile

42.6%

The FPC (Flexible PIC Concentrator) of Juniper Networks Junos OS and Junos OS Evolved may restart after processing a specific IPv4 packet. Only packets destined to the device itself, successfully reaching the RE through existing edge and control plane filtering, will be able to cause the FPC restart. When this issue occurs, all traffic via the FPC will be dropped. By continuously sending this specific IPv4 packet, an attacker can repeatedly crash the FPC, causing an extended Denial of Service (DoS) condition. This issue can only occur when processing a specific IPv4 packet. IPv6 packets cannot trigger this issue. This issue affects: Juniper Networks Junos OS on MX Series with MPC10E or MPC11E and PTX10001: 19.2 versions prior to 19.2R1-S4, 19.2R2; 19.3 versions prior to 19.3R2-S2, 19.3R3; 19.4 versions prior to 19.4R1-S1, 19.4R2. Juniper Networks Junos OS Evolved on on QFX5220, and PTX10003 series: 19.2-EVO versions; 19.3-EVO versions; 19.4-EVO versions prior to 19.4R2-EVO. This issue does not affect Junos OS versions prior to 19.2R1. This issue does not affect Junos OS Evolved versions prior to 19.2R1-EVO.

CNA Affected

[
  {
    "platforms": [
      "MX Series with MPC10E or MPC11E and PTX10001"
    ],
    "product": "Junos OS",
    "vendor": "Juniper Networks",
    "versions": [
      {
        "lessThan": "19.2R1-S4, 19.2R2",
        "status": "affected",
        "version": "19.2",
        "versionType": "custom"
      },
      {
        "lessThan": "19.3R2-S2, 19.3R3",
        "status": "affected",
        "version": "19.3",
        "versionType": "custom"
      },
      {
        "lessThan": "19.4R1-S1, 19.4R2",
        "status": "affected",
        "version": "19.4",
        "versionType": "custom"
      }
    ]
  },
  {
    "product": "Junos OS",
    "vendor": "Juniper Networks",
    "versions": [
      {
        "lessThan": "19.2R1",
        "status": "unaffected",
        "version": "unspecified",
        "versionType": "custom"
      }
    ]
  },
  {
    "platforms": [
      "QFX5220, and PTX10003 series"
    ],
    "product": "Junos OS Evolved",
    "vendor": "Juniper Networks",
    "versions": [
      {
        "status": "affected",
        "version": "19.2-EVO"
      },
      {
        "status": "affected",
        "version": "19.3-EVO 19.2-EVO"
      },
      {
        "lessThan": "19.4R2-EVO",
        "status": "affected",
        "version": "19.4-EVO",
        "versionType": "custom"
      }
    ]
  },
  {
    "product": "Junos OS Evolved",
    "vendor": "Juniper Networks",
    "versions": [
      {
        "lessThan": "19.2R1-EVO",
        "status": "unaffected",
        "version": "unspecified",
        "versionType": "custom"
      }
    ]
  }
]

7.5 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

UNCHANGED

Confidentiality Impact

NONE

Integrity Impact

NONE

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

0.001 Low

EPSS

Percentile

42.6%

Related for CVELIST:CVE-2020-1638