Lucene search

K
cvelistRapid7CVELIST:CVE-2019-5617
HistorySep 10, 2019 - 12:00 a.m.

CVE-2019-5617 C4G BLIS Improper Access Control

2019-09-1000:00:00
CWE-284
rapid7
www.cve.org

10 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

CHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H

9.7 High

AI Score

Confidence

High

0.006 Low

EPSS

Percentile

78.6%

Computing For Good’s Basic Laboratory Information System (also known as C4G BLIS) version 3.4 and earlier suffers from an instance of CWE-284, “Improper Access Control.” As a result, an unauthenticated user may change the password of any administrator-level user.

CNA Affected

[
  {
    "product": "Basic Laboratory Information System",
    "vendor": "Computing For Good",
    "versions": [
      {
        "lessThanOrEqual": "3.4",
        "status": "affected",
        "version": "unspecified",
        "versionType": "custom"
      }
    ]
  }
]

10 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

NONE

Scope

CHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H

9.7 High

AI Score

Confidence

High

0.006 Low

EPSS

Percentile

78.6%

Related for CVELIST:CVE-2019-5617