Lucene search
+L

CVE-2025-40935

🗓️ 09 Dec 2025 10:44:34Reported by siemensType 
cve
 cve
🔗 web.nvd.nist.gov👁 42 Views

Authenticated attacker can crash and reboot affected Ruggedcom devices during certificate upload, causing temporary denial of service.

Related
Detection
Affected
Refs
ReporterTitlePublishedViews
Family
bdu_fstec
BDU FSTEC
RUGGEDCOM ROS Ethernet Switch DoS
15 Dec 202500:00
–bdu_fstec
cnnvd
CNNVD
Siemens RUGGEDCOM input validation error vulnerability
9 Dec 202500:00
–cnnvd
cvelist
Cvelist
CVE-2025-40935
9 Dec 202510:44
–cvelist
euvd
EUVD
EUVD-2025-201920
9 Dec 202518:30
–euvd
ics
ICS
Siemens RUGGEDCOM ROS
9 Dec 202500:00
–ics
ncsc
NCSC
Vulnerabilities fixed in Siemens products
9 Dec 202513:15
–ncsc
nvd
NVD
CVE-2025-40935
9 Dec 202516:17
–nvd
ptsecurity
Positive Technologies
PT-2025-49841
9 Dec 202500:00
–ptsecurity
rapid7
Rapid7 Vulnerability Database (full)
CVE-2025-40935: Improper Input Validation
9 Dec 202500:00
–rapid7
redhatcve
RedhatCVE
CVE-2025-40935
9 Jan 202609:16
–redhatcve
Rows per page
[
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RMC8388 V5.X",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V5.10.1",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS416Pv2 V5.X",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V5.10.1",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS416v2 V5.X",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V5.10.1",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS900 (32M) V5.X",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V5.10.1",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RS900G (32M) V5.X",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V5.10.1",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RSG2100 (32M) V5.X",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V5.10.1",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RSG2100P (32M) V5.X",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V5.10.1",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RSG2288 V5.X",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V5.10.1",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RSG2300 V5.X",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V5.10.1",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RSG2300P V5.X",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V5.10.1",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RSG2488 V5.X",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V5.10.1",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RSG907R",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V5.10.1",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RSG908C",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V5.10.1",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RSG909R",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V5.10.1",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RSG910C",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V5.10.1",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RSG920P V5.X",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V5.10.1",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RSL910",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V5.10.1",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RST2228",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V5.10.1",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RST2228P",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V5.10.1",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RST916C",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V5.10.1",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "RUGGEDCOM RST916P",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V5.10.1",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  }
]

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation

07 Oct 2026 11:10Current
6.3Medium risk
Vulners AI Score6.3
CVSS 3.14.3
CVSS 45.3
EPSS0.00248
SSVC
42