CVSS3
Attack Vector
LOCAL
Attack Complexity
LOW
Privileges Required
NONE
User Interaction
REQUIRED
Scope
UNCHANGED
Confidentiality Impact
HIGH
Integrity Impact
HIGH
Availability Impact
HIGH
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
EPSS
Percentile
45.9%
A vulnerability has been identified in JT2Go (All versions < V14.3.0.1), Teamcenter Visualization V13.3 (All versions < V13.3.0.12), Teamcenter Visualization V14.0 (All versions), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.1), Tecnomatix Plant Simulation V2201 (All versions < V2201.0010), Tecnomatix Plant Simulation V2302 (All versions < V2302.0004). The affected application is vulnerable to stack-based buffer overflow while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20818)
Vendor | Product | Version | CPE |
---|---|---|---|
siemens | jt2go | * | cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:* |
siemens | teamcenter_visualization | * | cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:* |
siemens | tecnomatix_plant_simulation | * | cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:* |
[
{
"vendor": "Siemens",
"product": "JT2Go",
"versions": [
{
"version": "All versions < V14.3.0.1",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Teamcenter Visualization V13.3",
"versions": [
{
"version": "All versions < V13.3.0.12",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Teamcenter Visualization V14.0",
"versions": [
{
"version": "All versions",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Teamcenter Visualization V14.1",
"versions": [
{
"version": "All versions < V14.1.0.11",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Teamcenter Visualization V14.2",
"versions": [
{
"version": "All versions < V14.2.0.6",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Teamcenter Visualization V14.3",
"versions": [
{
"version": "All versions < V14.3.0.1",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Tecnomatix Plant Simulation V2201",
"versions": [
{
"version": "All versions < V2201.0010",
"status": "affected"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Tecnomatix Plant Simulation V2302",
"versions": [
{
"version": "All versions < V2302.0004",
"status": "affected"
}
],
"defaultStatus": "unknown"
}
]