Lucene search
K

CVE-2023-32735

🗓️ 09 Jul 2024 12:04:26Reported by siemensType 
cve
 cve
🔗 web.nvd.nist.gov👁 48 Views

Vulnerability in SIMATIC STEP 7 Safety and WinCC Unifie

Related
Affected
Refs
ReporterTitlePublishedViews
Family
CNNVD
Siemens SIMATIC WinCC和SIMATIC STEP 代码问题漏洞
9 Jul 202400:00
cnnvd
CNVD
Siemens Engineering Platforms Catalog Configuration File Deserialization Vulnerability
10 Jul 202400:00
cnvd
Cvelist
CVE-2023-32735
9 Jul 202412:04
cvelist
EUVD
EUVD-2023-36960
3 Oct 202520:07
euvd
ICS
Siemens TIA Portal, SIMATIC, and SIRIUS
9 Jul 202400:00
ics
NCSC
Vulnerabilities fixed in Siemens Products
9 Jul 202418:40
ncsc
NVD
CVE-2023-32735
9 Jul 202412:15
nvd
Positive Technologies
PT-2024-5108 · Siemens · Simocode Es +10
9 Jul 202400:00
ptsecurity
RedhatCVE
CVE-2023-32735
23 May 202504:29
redhatcve
Vulnrichment
CVE-2023-32735
9 Jul 202412:04
vulnrichment
Rows per page
[
  {
    "vendor": "Siemens",
    "product": "SIMATIC STEP 7 Safety V16",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V16 Update 7",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "SIMATIC STEP 7 Safety V17",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V17 Update 7",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "SIMATIC STEP 7 Safety V18",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V18 Update 2",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "SIMATIC STEP 7 V16",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V16 Update 7",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "SIMATIC STEP 7 V17",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V17 Update 7",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "SIMATIC STEP 7 V18",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V18 Update 2",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "SIMATIC WinCC Unified V16",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V16 Update 7",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "SIMATIC WinCC Unified V17",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V17 Update 7",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "SIMATIC WinCC Unified V18",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V18 Update 2",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "SIMATIC WinCC V16",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V16.7",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "SIMATIC WinCC V17",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V17.7",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "SIMATIC WinCC V18",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V18 Update 2",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "SIMOCODE ES V16",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V16 Update 7",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "SIMOCODE ES V17",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V17 Update 7",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "SIMOCODE ES V18",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V18 Update 2",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "SIMOTION SCOUT TIA V5.4 SP1",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "*",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "SIMOTION SCOUT TIA V5.4 SP3",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "*",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "SIMOTION SCOUT TIA V5.5 SP1",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "*",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "SINAMICS Startdrive V16",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "*",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "SINAMICS Startdrive V17",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "*",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "SINAMICS Startdrive V18",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "*",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "SIRIUS Safety ES V17",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V17 Update 7",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "SIRIUS Safety ES V18",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V18 Update 2",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "SIRIUS Soft Starter ES V17",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V17 Update 7",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "SIRIUS Soft Starter ES V18",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V18 Update 2",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "Soft Starter ES V16",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V16 Update 7",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "TIA Portal Cloud V3.0",
    "versions": [
      {
        "status": "affected",
        "version": "0",
        "lessThan": "V18 Update 2",
        "versionType": "custom"
      }
    ],
    "defaultStatus": "unknown"
  }
]

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation

15 Apr 2026 00:35Current
7.7High risk
Vulners AI Score7.7
CVSS 3.16.5
CVSS 47
EPSS0.00058
SSVC
48