sel rtac
database
passwords
retrieval
nvd

8 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

HIGH

Privileges Required

HIGH

User Interaction

NONE

Scope

CHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H

6.3 Medium

AI Score

Confidence

High

0.001 Low

EPSS

Percentile

45.5%

A Storing Passwords in a Recoverable Format vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) database system could allow an authenticated attacker to retrieve passwords.
See SEL Service Bulletin dated 2022-11-15 for more details.

Affected configurations

NVD
Node
selincsel-2241_rtac_module_firmwareRanger122-v0r150-v2
AND
selincsel-2241_rtac_moduleMatch-
Node
selincsel-3350_firmwareRanger148-v0r150-v2
AND
selincsel-3350Match-
Node
selincsel-3505_firmwareRanger122-v0r150-v2
AND
selincsel-3505Match-
Node
selincsel-3505-3_firmwareRanger132-v0r150-v2
AND
selincsel-3505-3Match-
Node
selincsel-3530_firmwareRanger122-v0r150-v2
AND
selincsel-3530Match-
Node
selincsel-3530-4_firmwareRanger122-v0r150-v2
AND
selincsel-3530-4Match-
Node
selincsel-3532_firmwareRanger132-v0r150-v2
AND
selincsel-3532Match-
Node
selincsel-3555_firmwareRanger134-v0r150-v2
AND
selincsel-3555Match-
Node
selincsel-3560e_firmwareRanger144-v2r150-v2
AND
selincsel-3560eMatch-
Node
selincsel-3560s_firmwareRanger144-v2r150-v2
AND
selincsel-3560sMatch-

CNA Affected

[
  {
    "defaultStatus": "unaffected",
    "modules": [
      "Database"
    ],
    "platforms": [
      "Linux"
    ],
    "product": "SEL-3505",
    "vendor": "Schweitzer Engineering Laboratories",
    "versions": [
      {
        "lessThan": "R150-V2",
        "status": "affected",
        "version": "R122-V0",
        "versionType": "custom"
      },
      {
        "lessThan": "R149-V4",
        "status": "affected",
        "version": "R122-V0",
        "versionType": "custom"
      },
      {
        "lessThan": "R148-V7",
        "status": "affected",
        "version": "R122-V0",
        "versionType": "custom"
      },
      {
        "lessThan": "R147-V6",
        "status": "affected",
        "version": "R122-V0",
        "versionType": "custom"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "modules": [
      "Database"
    ],
    "platforms": [
      "Linux"
    ],
    "product": "SEL-3505-3",
    "vendor": "Schweitzer Engineering Laboratories",
    "versions": [
      {
        "lessThan": "R150-V2",
        "status": "affected",
        "version": "R132-V0",
        "versionType": "custom"
      },
      {
        "lessThan": "R149-V4",
        "status": "affected",
        "version": "R132-V0",
        "versionType": "custom"
      },
      {
        "lessThan": "R148-V7",
        "status": "affected",
        "version": "R132-V0",
        "versionType": "custom"
      },
      {
        "lessThan": "R147-V6",
        "status": "affected",
        "version": "R132-V0",
        "versionType": "custom"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "modules": [
      "Database"
    ],
    "platforms": [
      "Linux"
    ],
    "product": "SEL-3530",
    "vendor": "Schweitzer Engineering Laboratories",
    "versions": [
      {
        "lessThan": "R150-V2",
        "status": "affected",
        "version": "R122-V0",
        "versionType": "custom"
      },
      {
        "lessThan": "R149-V4",
        "status": "affected",
        "version": "R122-V0",
        "versionType": "custom"
      },
      {
        "lessThan": "R148-V7",
        "status": "affected",
        "version": "R122-V0",
        "versionType": "custom"
      },
      {
        "lessThan": "R147-V6",
        "status": "affected",
        "version": "R122-V0",
        "versionType": "custom"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "modules": [
      "Database"
    ],
    "platforms": [
      "Linux"
    ],
    "product": "SEL-3530-4",
    "vendor": "Schweitzer Engineering Laboratories",
    "versions": [
      {
        "lessThan": "R150-V2",
        "status": "affected",
        "version": "R122-V0",
        "versionType": "custom"
      },
      {
        "lessThan": "R149-V4",
        "status": "affected",
        "version": "R122-V0",
        "versionType": "custom"
      },
      {
        "lessThan": "R148-V7",
        "status": "affected",
        "version": "R122-V0",
        "versionType": "custom"
      },
      {
        "lessThan": "R147-V6",
        "status": "affected",
        "version": "R122-V0",
        "versionType": "custom"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "modules": [
      "Database"
    ],
    "platforms": [
      "Linux"
    ],
    "product": "SEL-3532",
    "vendor": "Schweitzer Engineering Laboratories",
    "versions": [
      {
        "lessThan": "R150-V2",
        "status": "affected",
        "version": "R132-V0",
        "versionType": "custom"
      },
      {
        "lessThan": "R149-V4",
        "status": "affected",
        "version": "R132-V0",
        "versionType": "custom"
      },
      {
        "lessThan": "R148-V7",
        "status": "affected",
        "version": "R132-V0",
        "versionType": "custom"
      },
      {
        "lessThan": "R147-V6",
        "status": "affected",
        "version": "R132-V0",
        "versionType": "custom"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "modules": [
      "Database"
    ],
    "platforms": [
      "Linux"
    ],
    "product": "SEL-3555",
    "vendor": "Schweitzer Engineering Laboratories",
    "versions": [
      {
        "lessThan": "R150-V2",
        "status": "affected",
        "version": "R134-V0",
        "versionType": "custom"
      },
      {
        "lessThan": "R149-V4",
        "status": "affected",
        "version": "R134-V0",
        "versionType": "custom"
      },
      {
        "lessThan": "R148-V7",
        "status": "affected",
        "version": "R134-V0",
        "versionType": "custom"
      },
      {
        "lessThan": "R147-V6",
        "status": "affected",
        "version": "R134-V0",
        "versionType": "custom"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "modules": [
      "Database"
    ],
    "platforms": [
      "Linux"
    ],
    "product": "SEL-3560S",
    "vendor": "Schweitzer Engineering Laboratories",
    "versions": [
      {
        "lessThan": "R150-V2",
        "status": "affected",
        "version": "R144-V2",
        "versionType": "custom"
      },
      {
        "lessThan": "R149-V4",
        "status": "affected",
        "version": "R144-V2",
        "versionType": "custom"
      },
      {
        "lessThan": "R148-V7",
        "status": "affected",
        "version": "R144-V2",
        "versionType": "custom"
      },
      {
        "lessThan": "R147-V6",
        "status": "affected",
        "version": "R144-V2",
        "versionType": "custom"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "modules": [
      "Database"
    ],
    "platforms": [
      "Linux"
    ],
    "product": "SEL-3560E",
    "vendor": "Schweitzer Engineering Laboratories",
    "versions": [
      {
        "lessThan": "R150-V2",
        "status": "affected",
        "version": "R144-V2",
        "versionType": "custom"
      },
      {
        "lessThan": "R149-V4",
        "status": "affected",
        "version": "R144-V2",
        "versionType": "custom"
      },
      {
        "lessThan": "R148-V7",
        "status": "affected",
        "version": "R144-V2",
        "versionType": "custom"
      },
      {
        "lessThan": "R147-V6",
        "status": "affected",
        "version": "R144-V2",
        "versionType": "custom"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "modules": [
      "Database"
    ],
    "platforms": [
      "Linux"
    ],
    "product": "SEL-2241 RTAC module",
    "vendor": "Schweitzer Engineering Laboratories",
    "versions": [
      {
        "lessThan": "R150-V2",
        "status": "affected",
        "version": "R122-V0",
        "versionType": "custom"
      },
      {
        "lessThan": "R149-V4",
        "status": "affected",
        "version": "R122-V0",
        "versionType": "custom"
      },
      {
        "lessThan": "R148-V7",
        "status": "affected",
        "version": "R122-V0",
        "versionType": "custom"
      },
      {
        "lessThan": "R147-V6",
        "status": "affected",
        "version": "R122-V0",
        "versionType": "custom"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "modules": [
      "Database"
    ],
    "platforms": [
      "Linux"
    ],
    "product": "SEL-3350",
    "vendor": "Schweitzer Engineering Laboratories",
    "versions": [
      {
        "lessThan": "R150-V2",
        "status": "affected",
        "version": "R148-V0",
        "versionType": "custom"
      },
      {
        "lessThan": "R149-V4",
        "status": "affected",
        "version": "R148-V0",
        "versionType": "custom"
      },
      {
        "lessThan": "R148-V7",
        "status": "affected",
        "version": "R148-V0",
        "versionType": "custom"
      }
    ]
  }
]

8 High

CVSS3

Attack Vector

NETWORK

Attack Complexity

HIGH

Privileges Required

HIGH

User Interaction

NONE

Scope

CHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H

6.3 Medium

AI Score

Confidence

High

0.001 Low

EPSS

Percentile

45.5%

Related for CVE-2023-31150