A buffer overflow vulnerability in Rockwell Automation select 1756-EN* communication devices allows remote code execution via malicious CIP request

Related
Detection
Affected
Refs
NVD
[
  {
    "defaultStatus": "unaffected",
    "product": "1756-EN2T Series A, B, C",
    "vendor": "Rockwell Automation",
    "versions": [
      {
        "status": "affected",
        "version": "<=5.008 & 5.028"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "1756-EN2T Series D",
    "vendor": "Rockwell Automation",
    "versions": [
      {
        "status": "affected",
        "version": "<=11.002"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "1756-EN2TK Series A, B, C",
    "vendor": "Rockwell Automation",
    "versions": [
      {
        "status": "affected",
        "version": "<=5.008 & 5.028"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "1756-EN2TXT Series A, B, C",
    "vendor": "Rockwell Automation",
    "versions": [
      {
        "status": "affected",
        "version": "<=5.008 & 5.028"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "1756-EN2TXT Series D",
    "vendor": "Rockwell Automation",
    "versions": [
      {
        "status": "affected",
        "version": "<=11.002"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "1756-EN2TP Series A",
    "vendor": "Rockwell Automation",
    "versions": [
      {
        "status": "affected",
        "version": "<=11.002"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "1756-EN2TPK Series A",
    "vendor": "Rockwell Automation",
    "versions": [
      {
        "status": "affected",
        "version": "<=11.002"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "1756-EN2TPXT Series A",
    "vendor": "Rockwell Auotmation",
    "versions": [
      {
        "status": "affected",
        "version": "<=11.002"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "1756-EN2TR Series A, B",
    "vendor": "Rockwell Automation",
    "versions": [
      {
        "status": "affected",
        "version": "<=5.008 & 5.028"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "1756-EN2TR Series C",
    "vendor": "Rockwell Automation",
    "versions": [
      {
        "status": "affected",
        "version": "<=11.002"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "1756-EN2TRK Series A, B",
    "vendor": "Rockwell Automation",
    "versions": [
      {
        "status": "affected",
        "version": "<=5.008 & 5.028"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "1756-EN2TRK Series C",
    "vendor": "Rockwell Automation",
    "versions": [
      {
        "status": "affected",
        "version": "<=11.002"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "1756-EN2TRXT Series A, B",
    "vendor": "Rockwell Automation",
    "versions": [
      {
        "status": "affected",
        "version": "<=5.008 & 5.028"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "1756-EN2TRXT Series C",
    "vendor": "Rockwell Automation",
    "versions": [
      {
        "status": "affected",
        "version": "<=11.002"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "1756-EN2F Series A, B",
    "vendor": "Rockwell Automation",
    "versions": [
      {
        "status": "affected",
        "version": "<=5.008 & 5.028"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "1756-EN2F Series C",
    "vendor": "Rockwell Automation",
    "versions": [
      {
        "status": "affected",
        "version": "<=11.002"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "1756-EN2FK Series A, B",
    "vendor": "Rockwell Automation",
    "versions": [
      {
        "status": "affected",
        "version": "<=5.008 & 5.028"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "1756-EN2FK Series C",
    "vendor": "Rockwell Automation",
    "versions": [
      {
        "status": "affected",
        "version": "<=11.002"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "1756-EN3TR Series A",
    "vendor": "Rockwell Automation",
    "versions": [
      {
        "status": "affected",
        "version": "<=5.008 & 5.028"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "1756-EN3TR Series B",
    "vendor": "Rockwell Automation",
    "versions": [
      {
        "status": "affected",
        "version": "<=11.003"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "1756-EN3TRK Series A",
    "vendor": "Rockwell Automation",
    "versions": [
      {
        "status": "affected",
        "version": "<=5.008 & 5.028"
      }
    ]
  },
  {
    "defaultStatus": "unaffected",
    "product": "1756-EN3TRK Series B",
    "vendor": "Rockwell Automation",
    "versions": [
      {
        "status": "affected",
        "version": "<=11.002"
      }
    ]
  }
]

Data

Build on a solid foundation with Vulners data

We provide the essential building blocks for cybersecurity solutions with comprehensive, structured, and constantly updated vulnerability and exploits data

Api

Power your application with Vulners API

The Vulners REST API offers reliable, high-performance access to vulnerability intelligence, with 99.9% SLA uptime and CDN-backed data delivery for seamless global access

App

Assess and manage vulnerabilities with Vulners tools

Built on top of Vulners' database and SDK, end-user solutions give security professionals and developers lightweight and powerful tools for vulnerability remediation

21 Nov 2024 07:58Current
9.9High risk
Vulners AI Score9.9
CVSS 3.19.8
EPSS0.04482
SSVC
59