Lucene search

K
cve[email protected]CVE-2022-39157
HistoryNov 08, 2022 - 11:15 a.m.

CVE-2022-39157

2022-11-0811:15:11
CWE-125
web.nvd.nist.gov
22
2
vulnerability
parasolid
simcenter femap
code execution
x_t files
cve-2022-39157

7.8 High

CVSS3

Attack Vector

LOCAL

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

REQUIRED

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

0.001 Low

EPSS

Percentile

29.5%

A vulnerability has been identified in Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.0 (All versions >= V34.0.252 < V34.0.254), Parasolid V34.1 (All versions < V34.1.242), Parasolid V34.1 (All versions >= V34.1.242 < V34.1.244), Parasolid V35.0 (All versions < V35.0.170), Parasolid V35.0 (All versions >= V35.0.170 < V35.0.184), Simcenter Femap (All versions < V2023.1). The affected application contains an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17745)

Affected configurations

NVD
Node
siemensparasolidRange34.0.25234.0.254
OR
siemensparasolidRange34.1.24234.1.244
OR
siemensparasolidRange35.0.17035.0.184

CNA Affected

[
  {
    "vendor": "Siemens",
    "product": "Parasolid V34.0",
    "versions": [
      {
        "version": "All versions < V34.0.252",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "Parasolid V34.0",
    "versions": [
      {
        "version": "All versions >= V34.0.252 < V34.0.254",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "Parasolid V34.1",
    "versions": [
      {
        "version": "All versions < V34.1.242",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "Parasolid V34.1",
    "versions": [
      {
        "version": "All versions >= V34.1.242 < V34.1.244",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "Parasolid V35.0",
    "versions": [
      {
        "version": "All versions < V35.0.170",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "Parasolid V35.0",
    "versions": [
      {
        "version": "All versions >= V35.0.170 <  V35.0.184",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  },
  {
    "vendor": "Siemens",
    "product": "Simcenter Femap",
    "versions": [
      {
        "version": "All versions < V2023.1",
        "status": "affected"
      }
    ],
    "defaultStatus": "unknown"
  }
]

Social References

More

7.8 High

CVSS3

Attack Vector

LOCAL

Attack Complexity

LOW

Privileges Required

NONE

User Interaction

REQUIRED

Scope

UNCHANGED

Confidentiality Impact

HIGH

Integrity Impact

HIGH

Availability Impact

HIGH

CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

0.001 Low

EPSS

Percentile

29.5%

Related for CVE-2022-39157