Description
A CWE-521: Weak Password Requirements vulnerability exists that could allow an attacker to gain control of the device when the attacker brute forces the password. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)
Affected Software
{"id": "CVE-2022-32513", "vendorId": null, "type": "cve", "bulletinFamily": "NVD", "title": "CVE-2022-32513", "description": "A CWE-521: Weak Password Requirements vulnerability exists that could allow an attacker to gain control of the device when the attacker brute forces the password. Affected Products: C-Bus Network Automation Controller - LSS5500NAC (Versions prior to V1.10.0), Wiser for C-Bus Automation Controller - LSS5500SHAC (Versions prior to V1.10.0), Clipsal C-Bus Network Automation Controller - 5500NAC (Versions prior to V1.10.0), Clipsal Wiser for C-Bus Automation Controller - 5500SHAC (Versions prior to V1.10.0), SpaceLogic C-Bus Network Automation Controller - 5500NAC2 (Versions prior to V1.10.0), SpaceLogic C-Bus Application Controller - 5500AC2 (Versions prior to V1.10.0)", "published": "2023-01-30T23:15:00", "modified": "2023-02-08T16:56:00", "epss": [{"cve": "CVE-2022-32513", "epss": 0.0008, "percentile": 0.32895, "modified": "2023-06-03"}], "cvss": {"score": 7.5, "vector": "AV:N/AC:L/Au:N/C:P/I:P/A:P"}, "cvss2": {"cvssV2": {"version": "2.0", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "accessVector": "NETWORK", "accessComplexity": "LOW", "authentication": "NONE", "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "availabilityImpact": "PARTIAL", "baseScore": 7.5}, "severity": "HIGH", "exploitabilityScore": 10.0, "impactScore": 6.4, "acInsufInfo": false, "obtainAllPrivilege": false, "obtainUserPrivilege": false, "obtainOtherPrivilege": false, "userInteractionRequired": false}, "cvss3": {"cvssV3": {"version": "3.1", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "attackVector": "NETWORK", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "NONE", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL"}, "exploitabilityScore": 3.9, "impactScore": 5.9}, "href": "https://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2022-32513", "reporter": "cybersecurity@schneider-electric.com", "references": ["https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-06_C-Bus_Home_Automation_Products_Security_Notification.pdf"], "cvelist": ["CVE-2022-32513"], "immutableFields": [], "lastseen": "2023-06-03T14:42:29", "viewCount": 11, "enchantments": {"score": {"value": 4.9, "vector": "NONE"}, "affected_software": {"major_version": [{"name": "schneider-electric 5500ac2 firmware", "version": 1}, {"name": "schneider-electric 5500nac firmware", "version": 1}, {"name": "schneider-electric 5500nac2 firmware", "version": 1}, {"name": "schneider-electric 5500shac firmware", "version": 1}, {"name": "schneider-electric lss5500nac firmware", "version": 1}, {"name": "schneider-electric lss5500shac firmware", "version": 1}]}, "epss": [{"cve": "CVE-2022-32513", "epss": 0.0008, "percentile": 0.32761, "modified": "2023-05-02"}], "vulnersScore": 4.9}, "_state": {"dependencies": 1685838547, "score": 1685803863, "affected_software_major_version": 0, "epss": 0}, "_internal": {"score_hash": "ca4125803c38fdb3beb58ea8d3da5e4b"}, "cna_cvss": {"cna": "Schneider Electric SE", "cvss": {"3": {"vector": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "score": 9.8}}}, "cpe": [], "cpe23": [], "cwe": ["CWE-521"], "affectedSoftware": [{"cpeName": "schneider-electric:5500ac2_firmware", "version": "1.11.0", "operator": "lt", "name": "schneider-electric 5500ac2 firmware"}, {"cpeName": "schneider-electric:5500nac_firmware", "version": "1.11.0", "operator": "lt", "name": "schneider-electric 5500nac firmware"}, {"cpeName": "schneider-electric:5500nac2_firmware", "version": "1.11.0", "operator": "lt", "name": "schneider-electric 5500nac2 firmware"}, {"cpeName": "schneider-electric:5500shac_firmware", "version": "1.11.0", "operator": "lt", "name": "schneider-electric 5500shac firmware"}, {"cpeName": "schneider-electric:lss5500nac_firmware", "version": "1.11.0", "operator": "lt", "name": "schneider-electric lss5500nac firmware"}, {"cpeName": "schneider-electric:lss5500shac_firmware", "version": "1.11.0", "operator": "lt", "name": "schneider-electric lss5500shac firmware"}], "affectedConfiguration": [{"name": "schneider-electric 5500ac2", "cpeName": "schneider-electric:5500ac2", "version": "-", "operator": "eq"}, {"name": "schneider-electric 5500nac", "cpeName": "schneider-electric:5500nac", "version": "-", "operator": "eq"}, {"name": "schneider-electric 5500nac2", "cpeName": "schneider-electric:5500nac2", "version": "-", "operator": "eq"}, {"name": "schneider-electric 5500shac", "cpeName": "schneider-electric:5500shac", "version": "-", "operator": "eq"}, {"name": "schneider-electric lss5500nac", "cpeName": "schneider-electric:lss5500nac", "version": "-", "operator": "eq"}, {"name": "schneider-electric lss5500shac", "cpeName": "schneider-electric:lss5500shac", "version": "-", "operator": "eq"}], "cpeConfiguration": {"CVE_data_version": "4.0", "nodes": [{"operator": "AND", "children": [{"operator": "OR", "children": [], "cpe_match": [{"vulnerable": true, "cpe23Uri": "cpe:2.3:o:schneider-electric:5500ac2_firmware:1.11.0:*:*:*:*:*:*:*", "versionEndExcluding": "1.11.0", "cpe_name": []}]}, {"operator": "OR", "children": [], "cpe_match": [{"vulnerable": false, "cpe23Uri": "cpe:2.3:h:schneider-electric:5500ac2:-:*:*:*:*:*:*:*", "cpe_name": []}]}], "cpe_match": []}, {"operator": "AND", "children": [{"operator": "OR", "children": [], "cpe_match": [{"vulnerable": true, "cpe23Uri": "cpe:2.3:o:schneider-electric:5500nac_firmware:1.11.0:*:*:*:*:*:*:*", "versionEndExcluding": "1.11.0", "cpe_name": []}]}, {"operator": "OR", "children": [], "cpe_match": [{"vulnerable": false, "cpe23Uri": "cpe:2.3:h:schneider-electric:5500nac:-:*:*:*:*:*:*:*", "cpe_name": []}]}], "cpe_match": []}, {"operator": "AND", "children": [{"operator": "OR", "children": [], "cpe_match": [{"vulnerable": true, "cpe23Uri": "cpe:2.3:o:schneider-electric:5500nac2_firmware:1.11.0:*:*:*:*:*:*:*", "versionEndExcluding": "1.11.0", "cpe_name": []}]}, {"operator": "OR", "children": [], "cpe_match": [{"vulnerable": false, "cpe23Uri": "cpe:2.3:h:schneider-electric:5500nac2:-:*:*:*:*:*:*:*", "cpe_name": []}]}], "cpe_match": []}, {"operator": "AND", "children": [{"operator": "OR", "children": [], "cpe_match": [{"vulnerable": true, "cpe23Uri": "cpe:2.3:o:schneider-electric:5500shac_firmware:1.11.0:*:*:*:*:*:*:*", "versionEndExcluding": "1.11.0", "cpe_name": []}]}, {"operator": "OR", "children": [], "cpe_match": [{"vulnerable": false, "cpe23Uri": "cpe:2.3:h:schneider-electric:5500shac:-:*:*:*:*:*:*:*", "cpe_name": []}]}], "cpe_match": []}, {"operator": "AND", "children": [{"operator": "OR", "children": [], "cpe_match": [{"vulnerable": true, "cpe23Uri": "cpe:2.3:o:schneider-electric:lss5500nac_firmware:1.11.0:*:*:*:*:*:*:*", "versionEndExcluding": "1.11.0", "cpe_name": []}]}, {"operator": "OR", "children": [], "cpe_match": [{"vulnerable": false, "cpe23Uri": "cpe:2.3:h:schneider-electric:lss5500nac:-:*:*:*:*:*:*:*", "cpe_name": []}]}], "cpe_match": []}, {"operator": "AND", "children": [{"operator": "OR", "children": [], "cpe_match": [{"vulnerable": true, "cpe23Uri": "cpe:2.3:o:schneider-electric:lss5500shac_firmware:1.11.0:*:*:*:*:*:*:*", "versionEndExcluding": "1.11.0", "cpe_name": []}]}, {"operator": "OR", "children": [], "cpe_match": [{"vulnerable": false, "cpe23Uri": "cpe:2.3:h:schneider-electric:lss5500shac:-:*:*:*:*:*:*:*", "cpe_name": []}]}], "cpe_match": []}]}, "extraReferences": [{"url": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-06_C-Bus_Home_Automation_Products_Security_Notification.pdf", "name": "https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-06_C-Bus_Home_Automation_Products_Security_Notification.pdf", "refsource": "MISC", "tags": ["Patch", "Vendor Advisory"]}], "product_info": [{"vendor": "Schneider Electric", "product": "SpaceLogic C-Bus Network Automation Controller, 5500NAC2"}, {"vendor": "Schneider Electric", "product": "Wiser for C-Bus Automation Controller, LSS5500SHAC"}, {"vendor": "Schneider Electric", "product": "Clipsal C-Bus Network Automation Controller, 5500NAC"}, {"vendor": "Schneider Electric", "product": "SpaceLogic C-Bus Application Controller, 5500AC2"}, {"vendor": "Schneider Electric", "product": "Clipsal Wiser for C-Bus Automation Controller, 5500SHAC"}, {"vendor": "Schneider Electric", "product": "C-Bus Network Automation Controller, LSS5500NAC"}], "solutions": [], "workarounds": [], "impacts": [], "problemTypes": [{"descriptions": [{"type": "CWE", "lang": "en", "description": "CWE-521 Weak Password Requirements", "cweId": "CWE-521"}]}], "exploits": []}
{}